The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Lumbar erector spinae oxygenation during prolonged contractions: implications for prolonged work
Abstract
Owing to the recent interest in torso stabilization exercises together with many questions regarding the duration of prolonged isometric holds in occupational settings, the authors attempted to assess the level of back muscle oxygenation during prolonged isometric contractions. Specifically, this study recorded relative oxygen saturation of haemoglobin/myoglobin using Near Infrared Spectroscopy (NIRS) in the L3 erector mass during prolonged isometric contractions at intensities from 2 to 30% of maximum voluntary contraction (MVC). It was hypothesized that available oxygen to these muscles is severely compromised even at moderate levels of activation observed in occupational work. Eight volunteers without a history of lower back pain or injury participated in this study. The exercise task involved isometric contraction of the lower erector spinae at five different levels of each subject's maximal voluntary contraction: 2, 5, 10, 20 and 30% MVC, presented in random order. Subjects were placed in a sitting position, with a curved plastic plate secured horizontally to the pelvis to minimize movement at the hip joint. During extensor exertions, they were restrained with a harness that was attached at chest level to a load cell. Each isometric contraction was performed for 30 s followed by 1 min of rest. All levels of contraction demonstrated reduction in oxygen. Given the concern for motion artefact on the NIRS signal, sham trials were conducted where the subjects went through the procedure of attaching the pulling cable but no active pull was performed. These trials showed no change in the NIRS signal. At this time NIRS appears to be the only non-invasive instrumentation available to indicate total available muscle oxygen during low level, prolonged work. Although the specific tissue volume sampled by NIRS cannot be positively identified, it appears that tissue oxygenation in the lumbar extensor musculature is reduced as a function of contraction intensity, even at levels as low as 2% of MVC. These data have implications for prolonged work where postures requiring isometric contractions are sometimes held for hours, and where musculoskeletal illness has been linked to prolonged contraction levels above 2%MVC--these data suggest a possible biological pathway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 1×
“Near infrared spectroscopy (NIRS ) is based on the variable absorption of light in the near infrared range by oxygenated and deoxygenated forms of haemoglobin and myoglobin (Mancini et al. 1994 ).”
BackgroundWilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256
Costes, F., Barthelemy, J. C., Feasson, L., Busso, T., Geyssant, A., & Denis, C. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.4.1345 · Cited by 101 · cited 1×
“Some previous studies have shown a correlation between a reduction in the NIRS signal and reduced venous oxygen saturation (Wilson et al. 1989, Costes et al. 1996 ), although this does not con® rm that NIRS is sensitive to, or dominated by, venous oxygen.”
BackgroundComparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans
MacDonald, M. J., Tarnopolsky, M. A., Green, H. J., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.687 · Cited by 98 · cited 1×
“Recent investigations of NIRS during dynamic leg exercise showed proportional changes in the NIRS signal and venous blood oxygenation during the ® rst minute of exercise, although this relationship was not maintained later in exercise (MacDonald et al. 1999 ).”
BackgroundSelf-citation
Cited by
Core Training: Evidence Translating to Better Performance and Injury Prevention
McGill, S. (2010) · Strength & Conditioning Journal · doi:10.1519/ssc.0b013e3181df4521 · Cited by 324
Self-citationSedentary lifestyle as a risk factor for low back pain: a systematic review
Chen, S.-M., Liu, M.-F., Cook, J., Bass, S., & Lo, S. K. (2009) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-009-0410-0 · Cited by 284
McGill, S., Belore, M., Crosby, I., & Russell, C. (2010) · Occupational Ergonomics · doi:10.3233/oer-2010-0181 · Cited by 40
Self-citation
Metadata
- Authors
- McGill, S. M., Hughson, R. L., & Parks, K.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 2000-04
- Volume
- 43
- Issue
- 4
- Pages
- 486-493
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2136633481
- Cited by
- 170
- References
- 4
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lumbar erector spinae oxygenation during prolonged contractions: implications for prolonged work. https://app.cochat.ai/papers/10.1080/001401300184369
- The paper
- McGill, S. M., Hughson, R. L., & Parks, K. (2000). Lumbar erector spinae oxygenation during prolonged contractions: implications for prolonged work. Ergonomics. https://doi.org/10.1080/001401300184369
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.