Standing at a kiosk: Effects of key size and spacing on touch screen numeric keypad performance and user preference
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Touch screen input keys compete with other information for limited screen space. The present study estimated the smallest key size that would not degrade performance or user satisfaction. Twenty participants used finger touches to enter one, four or 10 digits in a numeric keypad displayed on a capacitive touch screen, while standing in front of a touch screen kiosk. Key size (10, 15, 20, 25 mm square) and edge-to-edge key spacing (1, 3 mm) were factorially combined. Performance was evaluated with response time and errors, and user preferences were obtained. Spacing had no measurable effects. Entry times were longer and errors were higher for smaller key sizes, but no significant differences were found between key sizes of 20 and 25 mm. Participants also preferred 20 mm keys to smaller keys, and they were indifferent between 20 and 25 mm keys. Therefore, a key size of 20 mm was found to be sufficiently large for land-on key entry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Using confidence intervals in within-subject designs
Loftus, G. R., & Masson, M. E. J. (1994) · Psychonomic Bulletin & Review · doi:10.3758/bf03210951 · Cited by 2,448 · cited 1×
“These three error terms were most relevant to the experimental questions and they were approximately equal in size (Loftus and Masson 1994).”
BackgroundFitts' Law as a Research and Design Tool in Human-Computer Interaction
MacKenzie, I. S. (1992) · Human–Computer Interaction · doi:10.1207/s15327051hci0701_3 · Cited by 1,637 · cited 2×
“It should be noted that the prediction about the relative effects of key size and key spacing also holds for some other definitions of the ID ratio (e.g. MacKenzie 1992).”
BackgroundMethodProceedings of the Human Factors and Ergonomics Society 54th Annual Meeting
Kluge, A., Badura, B., Urbas, L., & Burkolter, D. (2010) · Cited by 1,127
The Latency and Duration of Rapid Movement Sequences: Comparisons of Speech and Typewriting
Sternberg, S., Monsell, S., Knoll, R. L., & Wright, C. E. (1978) · Information Processing in Motor Control and Learning · doi:10.1016/b978-0-12-665960-3.50011-6 · Cited by 891
A neuropsychological theory of motor skill learning.
Willingham, D. B. (1998) · Psychological Review · doi:10.1037//0033-295x.105.3.558 · Cited by 799
Geometrical conditions for ballistic and visually controlled movements
GAN, K.-C., & HOFFMANN, E. R. (1988) · Ergonomics · doi:10.1080/00140138808966724 · Cited by 217
The Adult Human Hand: Some Anthropometric and Biomechanical Considerations
Garrett, J. W. (1971) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872087101300204 · Cited by 209 · cited 1×
“Garrett (1971) reported that the mean width of the index finger at the distal joint was 18.3 mm and 15.5 mm for male and female participants, respectively.”
BackgroundInfluentialInvestigating touchscreen typing: the effect of keyboard size on typing speed
SEARS, A., REVIS, D., SWATSKI, J., CRITTENDEN, R., & SHNEIDERMAN, B. (1993) · Behaviour & Information Technology · doi:10.1080/01449299308924362 · Cited by 146
Klapp, S. T. (2003) · Journal of Motor Behavior · doi:10.1080/00222890309602129 · Cited by 144 · cited 5×
“…relatively difficult response selection and motor programming for multiple responses were required because a choice paradigm was used in which participants did not know which response movement was to be executed until the imperative cue (the list of digits displayed) was presented (Klapp 1996, 2003).”
BackgroundMethodInfluentialMotor Behavior Models for Human-Computer Interaction
MacKenzie, I. S. (2003) · Elsevier eBooks · doi:10.1016/b978-155860808-5/50003-4 · Cited by 130 · cited 1×
“Predictive models for keypad entry of complex tasks incorporating some of these processes, along with some others, have been attempted (e.g. MacKenzie 2003, Pavlovych and Stuerzlinger 2004).”
Improving touchscreen keyboards: design issues and a comparison with other devices
Sears, A. (1991) · Interacting with Computers · doi:10.1016/0953-5438(91)90016-u · Cited by 125 · cited 2×
“1988, Beringer 1990, Leahy and Hix 1990, Sears 1991).”
InfluentialHall, A. D., Cunningham, J. B., Roache, R. P., & Cox, J. W. (1988) · Journal of Applied Psychology · doi:10.1037/0021-9010.73.4.711 · Cited by 80
Model for non-expert text entry speed on 12-button phone keypads
Pavlovych, A., & Stuerzlinger, W. (2004) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/985692.985737 · Cited by 57 · cited 1×
“Predictive models for keypad entry of complex tasks incorporating some of these processes, along with some others, have been attempted (e.g. MacKenzie 2003, Pavlovych and Stuerzlinger 2004).”
Whitfield, D., BALL, R. G., & BIRD, J. M. (1983) · Ergonomics · doi:10.1080/00140138308963437 · Cited by 56 · cited 2×
“Although a lift-off response criterion has been found to allow accurate entry with smaller key sizes (Sears et al. 1993, Scott and Conzola 1997, Whitfield et al. 1983), it is an atypical action for most keying devices and has not been used extensively for touch input.”
BackgroundA model for movement time on data-entry keyboards
Drury, C. G., & Hoffmann, E. R. (1992) · Ergonomics · doi:10.1080/00140139208967802 · Cited by 54
Designing Touch Screen Numeric Keypads: Effects of Finger Size, Key Size, and Key Spacing
Scott, B., & Conzola, V. (1997) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/107118139704100180 · Cited by 43 · cited 4×
“1993, Scott and Conzola 1997, Wilson et al .”
BackgroundInfluentialConfiguring a numeric keypad for a touch screen
MARTIN, G. L. (1988) · Ergonomics · doi:10.1080/00140138808966733 · Cited by 37 · cited 5×
“Both Martin (1988) and Beaton and Weiman (1984) manipulated key spacing, defining it as the edge-to-edge (not centre-to-centre) distance between adjacent keys.”
BackgroundResultInfluentialPerson-Computer Interface using Touch Screen Devices
Pfauth, M., & Priest, J. W. (1981) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1071181381025001129 · Cited by 32 · cited 1×
“In their early review of ergonomic issues in touch screen use, Pfauth and Priest (1981) identified key size as an important factor.”
BackgroundUsing a touchscreen for simple tasks
Gould, J. D., Greene, S. L., Boies, S. J., Meluson, A., & Rasamny, M. (1990) · Interacting with Computers · doi:10.1016/0953-5438(90)90014-9 · Cited by 27
Data-entry keyboard geometry and keying movement times
Hoffmann, E. R., TSANG, K. K., & MU, A. (1995) · Ergonomics · doi:10.1080/00140139508925161 · Cited by 23
Effects Of Touch Key Size And Separation On Menu-Selection Accuracy
Beaton, R. J., & Welman, N. (1985) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.946371 · Cited by 20 · cited 5×
“Both Martin (1988) and Beaton and Weiman (1984) manipulated key spacing, defining it as the edge-to-edge (not centre-to-centre) distance between adjacent keys.”
BackgroundResultInfluentialTarget Size, Location, Sampling Point and Instructional Set: More Effects on Touch Panel Operation
Beringer, D. B. (1990) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193129003400430 · Cited by 20 · cited 2×
“Only Beringer (1990) estimated a square envelope of 20 mm. Response variability studies measured accuracy for single touches.”
BackgroundMohagheghi, A. A., & Anson, J. G. (2002) · Acta Psychologica · doi:10.1016/s0001-6918(01)00051-8 · Cited by 14
A Comparison of Five User Interface Devices Designed for Point-of-Sale in the Retail Industry
Wilson, K. S., & Liu, M. I. S. (1995) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193129503900411 · Cited by 13
Optimum layout of an array of controls
Hoffmann, E. R. (1994) · International Journal of Industrial Ergonomics · doi:10.1016/0169-8141(94)90101-5 · Cited by 7
Research works printed but not linked: 7
- Bender GT 1999 Touch screen performance as a function of the duration of auditory feedback and target size Ph. D. dissertation Wichita State University, Kansas, USA
- Beringer DB, 1990, Proceedings of the Human Factors Society 34th Annual Meeting, 375
- Leahy M, 1990, Proceedings of the Human Factors Society 34th annual meeting, 370
- 10.1080/01449290210121879 · DOI
- Pfauth M, 1981, Proceedings of the Human Factors Society 25th Annual Meeting, 500
- Wilson KS, 1995, Proceedings of the Human Factors and Ergonomics Society 39th Annual Meeting, 273
- 10.1037/0033-295X.105.3.558 · doi:10.1037/0033-295x.105.3.558 · Paper page
Cited by
Target size study for one-handed thumb use on small touchscreen devices
Parhi, P., Karlson, A. K., & Bederson, B. B. (2006) · Proceedings of the 8th conference on Human-computer interaction with mobile devices and services · doi:10.1145/1152215.1152260 · Cited by 352
Touch Screen User Interfaces for Older Adults: Button Size and Spacing
Jin, Z. X., Plocher, T., & Kiff, L. (2007) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-73279-2_104 · Cited by 198
“In addition, consistent with previous studies [4,5,6,7,8,10], the majority of the subjects expressed a preference for buttons that were large, but not too large, 16.”
BackgroundResultPark, Y. S., & Han, S. H. (2010) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2009.08.002 · Cited by 161
The influence of age in usability testing
Sonderegger, A., Schmutz, S., & Sauer, J. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.06.012 · Cited by 152
“For older adults, there was a significant correlation between perceived usability and effectiveness but not between perceived usability and efficiency.”
BackgroundOne-handed thumb interaction of mobile devices from the input accuracy perspective
Park, Y. S., & Han, S. H. (2010) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2010.08.001 · Cited by 80
Metadata
- Authors
- Colle, H. A., & Hiszem, K. J.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 2004-10-22
- Volume
- 47
- Issue
- 13
- Pages
- 1406-1423
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W1981175587
- Cited by
- 185
- References
- 25
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.