Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A PRACTICAL METHOD OF ESTIMATING AN INDIVIDUAL'S MAXIMAL OXYGEN INTAKE

MARITZ, J. S., MORRISON, J. F., PETER, J., STRYDOM, N. B., WYNDHAM, C. H.·1961·Ergonomics

Abstract

The premises upon which simple methods for estimating an individual's maximum oxygen intake are based have boon tested. These premises are : (a) that heart rate and oxygen intake are linear functions of each other throughout the entire range of work up to the individual's maximum ; (b) that oxygen intake of the individual deviates very little from the mean straight line relating oxygon intake and rate of work for the population, so that the oxygon intake for a task performed against gravity can be estimated with reasonable precision from the rate of work ; and (c) that the individual variability of maximum heart rate round the mean for the population is sufficiently small to use the moan in a routine test procedure without the introduction of largo errors. Premises (b) and (c) are fully substantiated by the results reported here, Premise (a) is not strictly valid, as there is a bias of the order of 03 1. oxygon/min in the straight line relating heart rate and oxygen intake at high levels of work in most individuals. The errors involved in the method proposed by Åstrand (1954) based on these premises have been examined and compared with those of an alternative procedure described in the present paper. The variance of maximum oxygen intake using the Astrand method, duo to errors in measurement of heart rate alone, is of the order 0·53, compared with 0·26 of the procedure described in this paper. In addition, one measurement only of heart rate in the Åstrand method introduces a bias of about 0·3 1. oxygen/min in the estimate of an individual maximum oxygon capacity of 3·0 l/min. The variance of maximum oxygen intake by the present method can be reduced by fitting a straight line by least squares to plots of four pairs of heart rate and oxygen intake values at four rates of work.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00140136108930512

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 180

Metadata

Authors
MARITZ, J. S., MORRISON, J. F., PETER, J., STRYDOM, N. B., & WYNDHAM, C. H.
Venue
Ergonomics
Published
1961-04
Volume
4
Issue
2
Pages
97-122
ISSN
  • 0014-0139 (ISSN-L)
  • 1366-5847
OpenAlex
W2014747327
Cited by
180
References
1
FWCI
4.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A PRACTICAL METHOD OF ESTIMATING AN INDIVIDUAL'S MAXIMAL OXYGEN INTAKE. https://app.cochat.ai/papers/10.1080/00140136108930512
The paper
MARITZ, J. S., MORRISON, J. F., PETER, J., STRYDOM, N. B., & WYNDHAM, C. H. (1961). A PRACTICAL METHOD OF ESTIMATING AN INDIVIDUAL'S MAXIMAL OXYGEN INTAKE. Ergonomics. https://doi.org/10.1080/00140136108930512

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.