Evaluation of the amplitude and frequency components of the surface EMG as an index of muscle fatigue
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The frequency components and amplude of the surface electromyogram (EMG) were measured during both 3-s (tensions of 5-100% of the maximum voluntary contraction (MVC)) and fatiguing contractions at 25, 40 and 70% MVC in the handgrip, biceps, adductor pollicis and quadriceps muscles in six male subjects. For the handgrip and biceps muscles, the experiments were repeated at three different muscle lengths: the length at which the muscle was able to exert its maximum isometric strength, and the muscle length above and below that length which corresponded to a length at which the muscle could exert 80% of it maximum. The frequency components of the EMG were the same during brief fatiguing isometric contractions in any of the muscles examined here as long as the muscles contracted near their optimal length. Shortening the muscle length prior to contraction caused an increase in the power in the low frequencies of the EMG power spectra while stretching a muscle had the opposite effect during isometric contractions. The amplitude of the EMG during brief and fatiguing contractions were similar for all muscles except the biceps. The biceps showed a non-linear relation between the amplitude of the EMG and tension during brief isometric contractions and to a lesser extent during fatiguing contractions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
European Journal of Applied Physiology
(2013) · European Journal of Applied Physiology · doi:10.1007/421.1439-6327 · Cited by 997
The relation between force, velocity and integrated electrical activity in human muscles
Bigland, B., & Lippold, O. C. J. (1954) · The Journal of Physiology · doi:10.1113/jphysiol.1954.sp005044 · Cited by 766
The relation between the surface electromyogram and muscular force.
Milner‐Brown, H. S., & Stein, R. B. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010904 · Cited by 644
Lindström, L., Magnusson, R., & Petersén, I. (1970) · PubMed · Cited by 553
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION
(1957) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1957.tb59818.x · Cited by 462
(2012) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2011.11.007 · Cited by 369
Propagation velocity in human muscle fibers in situ.
Stålberg, E. (1966) · PubMed · Cited by 322
Signal characteristics of EMG during fatigue
Viitasalo, J. H. T., & Komi, P. V. (1977) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421697 · Cited by 295
The duration of sustained contractions of the human forearm at different muscle temperatures
Clarke, R. S. J., Hellon, R. F., & Lind, A. R. (1958) · The Journal of Physiology · doi:10.1113/jphysiol.1958.sp006071 · Cited by 254
Self-citationFrequency and amplitude analysis of the EMG during exercise on the bicycle ergometer
Petrofsky, J. S. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00424464 · Cited by 222
Self-citation
Cited by
Mathiassen, S. E., Winkel, J., & Hägg, G. M. (1995) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(94)00014-x · Cited by 516
Impairment of neuromuscular propagation during human fatiguing contractions at submaximal forces.
Fuglevand, A. J., Zackowski, K. M., Huey, K. A., & Enoka, R. M. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019486 · Cited by 415
Effect of a vibration exposure on muscular performance and body balance. Randomized cross‐over study
Torvinen, S., Kannus, P., Sievänen, H., Järvinen, T. A. H., Pasanen, M., Kontulainen, S., Järvinen, T. L. N., Järvinen, M., Oja, P., & Vuori, I. (2002) · Clinical Physiology and Functional Imaging · doi:10.1046/j.1365-2281.2002.00410.x · Cited by 414
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
The Usefulness of Mean and Median Frequencies in Electromyography Analysis
Phinyomark, A., Thongpanja, S., Hu, H., Phukpattaranont, P., & Limsakul, C. (2012) · Computational Intelligence in Electromyography Analysis - A Perspective on Current Applications and Future Challenges · doi:10.5772/50639 · Cited by 294
Potvin, J. R., & Brown, S. H. M. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2003.10.005 · Cited by 227
“During prolonged isometric contractions, sEMG amplitudes have been observed to increase in the absence of muscle force increases [2,14,34,40,44], making it problematic to use the sEMG from fatigued muscles to predict force.”
BackgroundAn experimental method to study the effect of fatigue on construction workers’ safety performance
Fang, D., Jiang, Z., Zhang, M., & Wang, H. (2015) · Safety Science · doi:10.1016/j.ssci.2014.11.019 · Cited by 225
“Objective measures of fatigue focus on the physiological processes (e.g. Electromyography (Petrofsky et al., 1982), Electrocardiography (Egelund, 1982) and Electroencephalographyn (Lal and Craig, 2001)) and subjective measures usually refer to fatigue assessment scales (Dittner et al., 2004).”
BackgroundMehta, R. K., & Agnew, M. J. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2264-x · Cited by 205
“Changes in EMG amplitude and power frequencies have been widely used to determine muscle fatigability (De Luca 1997; Petrofsky et al. 1982).”
MethodPotvin, J. R. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.144 · Cited by 184
Potvin, J. R., & Bent, L. R. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(96)00025-9 · Cited by 182
Shi, J., Zheng, Y. P., Chen, X., & Huang, Q. H. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.07.004 · Cited by 165
Physiology and Interpretation of the Electromyogram
Kamen, G., & Caldwell, G. E. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199609000-00002 · Cited by 160
Østensvik, T., Veiersted, K. B., & Nilsen, P. (2009) · Ergonomics · doi:10.1080/00140130903199889 · Cited by 52
“1982 , Aaras and Westgaard 1987 , Westgaard 1988 , Winter et al .”
BackgroundLooney, D. P., Kraemer, W. J., Joseph, M. F., Comstock, B. A., Denegar, C. R., Flanagan, S. D., Newton, R. U., Szivak, T. K., DuPont, W. H., Hooper, D. R., et al. (2016) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001109 · Cited by 46
Muddle, T. W. D., Colquhoun, R. J., Magrini, M. A., Luera, M. J., DeFreitas, J. M., & Jenkins, N. D. M. (2018) · Physiological Reports · doi:10.14814/phy2.13675 · Cited by 41
“However, it has been previously shown that, although muscle activation (i.e., EMG amplitude) increases throughout fatiguing submaximal isometric exercise, it may not reach maximal levels (Petrofsky et al. 1982; Fuglevand et al. 1993).”
BackgroundResult
Metadata
- Authors
- PETROFSKY, J. S., GLASER, R. M., PHILLIPS, C. A., LIND, A. R., & WILLIAMS, C.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1982-03
- Volume
- 25
- Issue
- 3
- Pages
- 213-223
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2049447155
- Cited by
- 207
- References
- 19
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.