Evaluation of the amplitude and frequency components of the surface EMG as an index of muscle fatigue
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The frequency components and amplude of the surface electromyogram (EMG) were measured during both 3-s (tensions of 5-100% of the maximum voluntary contraction (MVC)) and fatiguing contractions at 25, 40 and 70% MVC in the handgrip, biceps, adductor pollicis and quadriceps muscles in six male subjects. For the handgrip and biceps muscles, the experiments were repeated at three different muscle lengths: the length at which the muscle was able to exert its maximum isometric strength, and the muscle length above and below that length which corresponded to a length at which the muscle could exert 80% of it maximum. The frequency components of the EMG were the same during brief fatiguing isometric contractions in any of the muscles examined here as long as the muscles contracted near their optimal length. Shortening the muscle length prior to contraction caused an increase in the power in the low frequencies of the EMG power spectra while stretching a muscle had the opposite effect during isometric contractions. The amplitude of the EMG during brief and fatiguing contractions were similar for all muscles except the biceps. The biceps showed a non-linear relation between the amplitude of the EMG and tension during brief isometric contractions and to a lesser extent during fatiguing contractions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
European Journal of Applied Physiology
(2013) · European Journal of Applied Physiology · doi:10.1007/421.1439-6327 · Cited by 997
The relation between force, velocity and integrated electrical activity in human muscles
Bigland, B., & Lippold, O. C. J. (1954) · The Journal of Physiology · doi:10.1113/jphysiol.1954.sp005044 · Cited by 766
The relation between the surface electromyogram and muscular force.
Milner‐Brown, H. S., & Stein, R. B. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010904 · Cited by 644
Lindström, L., Magnusson, R., & Petersén, I. (1970) · PubMed · Cited by 553
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION
(1957) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1957.tb59818.x · Cited by 462
(2012) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2011.11.007 · Cited by 369
Propagation velocity in human muscle fibers in situ.
Stålberg, E. (1966) · PubMed · Cited by 322
Signal characteristics of EMG during fatigue
Viitasalo, J. H. T., & Komi, P. V. (1977) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421697 · Cited by 295
The duration of sustained contractions of the human forearm at different muscle temperatures
Clarke, R. S. J., Hellon, R. F., & Lind, A. R. (1958) · The Journal of Physiology · doi:10.1113/jphysiol.1958.sp006071 · Cited by 254
Self-citationFrequency and amplitude analysis of the EMG during exercise on the bicycle ergometer
Petrofsky, J. S. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00424464 · Cited by 222
Self-citationFrequency analysis of the surface electromyogram during sustained isometric contractions
Petrofsky, J. S., & Lind, A. R. (1980) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00422448 · Cited by 198
Self-citationKnowlton, G. C., BENNETT, R. L., & McCLURE, R. (1951) · PubMed · Cited by 183
Petrofsky, J. S., & Lind, A. R. (1980) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421098 · Cited by 179
Self-citationTHE ELECTROMYOGRAPHY OF FATIGUE
LIPPOLD, O. C. J., REDFEARN, J. W. T., & VUČO, J. (1960) · Ergonomics · doi:10.1080/00140136008930474 · Cited by 162
Influence of electrode geometry on bipolar recordings of the surface electromyogram
Lynn, P. A., Bettles, N. D., Hughes, A., & Johnson, S. (1978) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442444 · Cited by 153
Amplitude of the surface electromyogram during fatiguing isometric contractions
Lind, A. R., & Petrofsky, J. S. (1979) · Muscle & Nerve · doi:10.1002/mus.880020404 · Cited by 112
Self-citationElectromyographic study of local and generalized muscular impairment
Eason, R. G. (1960) · Journal of Applied Physiology · doi:10.1152/jappl.1960.15.3.479 · Cited by 54
MUSCLE ACTION POTENTIALS STUDIED BY FREQUENCY ANALYSIS AND DURATION MEASUREMENT
Kaiser, E., & Petersén, I. (2009) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1965.tb01876.x · Cited by 41
PETROFSKY, J. S., & Phillips, C. A. (1980) · PubMed · Cited by 39
Self-citation
Cited by
Mathiassen, S. E., Winkel, J., & Hägg, G. M. (1995) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(94)00014-x · Cited by 516
Impairment of neuromuscular propagation during human fatiguing contractions at submaximal forces.
Fuglevand, A. J., Zackowski, K. M., Huey, K. A., & Enoka, R. M. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019486 · Cited by 415
Effect of a vibration exposure on muscular performance and body balance. Randomized cross‐over study
Torvinen, S., Kannus, P., Sievänen, H., Järvinen, T. A. H., Pasanen, M., Kontulainen, S., Järvinen, T. L. N., Järvinen, M., Oja, P., & Vuori, I. (2002) · Clinical Physiology and Functional Imaging · doi:10.1046/j.1365-2281.2002.00410.x · Cited by 414
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
The Usefulness of Mean and Median Frequencies in Electromyography Analysis
Phinyomark, A., Thongpanja, S., Hu, H., Phukpattaranont, P., & Limsakul, C. (2012) · Computational Intelligence in Electromyography Analysis - A Perspective on Current Applications and Future Challenges · doi:10.5772/50639 · Cited by 294
Metadata
- Authors
- PETROFSKY, J. S., GLASER, R. M., PHILLIPS, C. A., LIND, A. R., & WILLIAMS, C.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1982-03
- Volume
- 25
- Issue
- 3
- Pages
- 213-223
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2049447155
- Cited by
- 207
- References
- 19
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.