A modified SCBA facepiece for accurate metabolic data collection from firefighters

Kesler, Richard M., Hsiao-Wecksler, Elizabeth T., Motl, Robert W., Klaren, Rachel E., Ensari, Ipek, Horn, Gavin P.·2015·Ergonomics

Abstract

To better assess the energy expenditure and exertion of firefighters during simulated firefighting activities, a commercial firefighter self-contained breathing apparatus (SCBA) facepiece was modified to interface with a portable metabolic monitoring device (Cosmed K4b(2)) while still functioning as a positive pressure SCBA air supply. To validate the device, standard National Fire Protection Association 1981 SCBA function tests were conducted and 14 subjects performed variable-workload assessments using all combinations of two test devices (Cosmed K4b(2) and metabolic cart) and two masks (modified SCBA facepiece and stock manufacturer-supplied breath collection). Metabolic data collected with the Cosmed K4b(2) via the modified facepiece were found to be accurate when compared to a ParvoMedics Truemax 2400 metabolic cart (average per cent difference: 4.6%). This modified facepiece design is suitable for use in metabolic studies requiring the utilisation of an SCBA system. Furthermore, the well-established overestimation of oxygen consumption from the Cosmed K4b(2) system was replicated.

Overview

Integrity signals

Registry

Crossref · 10.1080/00140139.2014.964783

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Accuracy metrics for individuals could misrepresent equation predictive accuracy because the measurement variability of the portable calorimeter would be present to an unknown extent.

    “Equally important, accuracy metrics for individuals could misrepresent equation predictive accuracy because the measurement variability of the portable calorimeter (22–28, Fig. 3) would be present to an unknown extent.”
  • The calorimeter model in question consistently exceeds well-validated laboratory systems under similar conditions by magnitudes ranging from 2% to 25%.

    “The calorimeter model in question consistently exceeds well-validated laboratory systems under similar conditions by magnitudes ranging from 2% to 25% (22–28).”
  • The Douglas bag, mass spectrometer, and other laboratory-based metabolic system assessments of the validity of the Cosmed K4b2 unit reported positive, but consistent within-study bias ranging from 2% to 25% across the relevant measurement range.

    “The Douglas bag, mass spectrometer, and other laboratory-based metabolic system assessments of the validity of the Cosmed K4b2 unit (22–28) we used reported positive, but consistent within-study bias ranging from 2% to 25% across the relevant measurement range.”

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 30

  1. Approval of Respiratory Protective Devices, Subpart H: Self-Contained Breathing Apparatus, 2010, 42 CFR 84.91 – Breathing Resistance Test; Exhalation
  2. 10.1080/02701367.1985.10608441 · DOI
  3. 10.1007/s00421-001-0572-2 · DOI
  4. Consolazio, C. F., Robert E.Johnson, and E.Marek. 1951. Metabolic Methods: Clinical Procedures in the Study of Metabolic Functions. St. Louis, MO: Henry Kimpton. · DOI
  5. 10.1519/JSC.0b013e3181bb72c0 · DOI
  6. 10.1080/00140130600667451 · DOI
  7. 10.1139/H07-020 · DOI
  8. 10.1016/S1440-2440(04)80039-2 · DOI · Paper page
  9. 10.1080/00140137908924636 · DOI
  10. Eisenmann J. C., 2003, Journal of Sports Medicine Physical Fitness, 43, 150
  11. 10.1080/00140130802120259 · DOI
  12. 10.1080/00140130210159986 · DOI
  13. 10.1007/s00421-008-0673-2 · DOI
  14. 10.1016/j.apergo.2006.01.004 · DOI
  15. Holmer I., 2006, International Journal of Occupational Safety and Ergonomics, 12, 297, 10.1080/10803548.2006.11076689 · DOI
  16. 10.1016/S0003-6870(01)00007-2 · DOI
  17. 10.1007/s00421-009-1092-8 · DOI
  18. 10.1034/j.1600-0838.2003.00319.x · DOI
  19. 10.1016/0169-8141(94)90080-9 · DOI
  20. 10.1055/s-2001-13816 · DOI · Paper page
  21. 10.1080/00140139.2010.489962 · DOI
  22. 10.1016/S1440-2440(01)80041-4 · DOI · Paper page
  23. 10.1080/00140139.2012.703696 · DOI
  24. 10.1080/00140139508925251 · DOI
  25. 10.1097/00043764-199208000-00014 · DOI
  26. 10.1207/s15327043hup0304_1 · DOI
  27. Stuart M. K., 1981, Journal of Applied Physiology, 50, 444, 10.1152/jappl.1981.50.2.444 · DOI
  28. Thomas S., 1992, Canadian Journal of Sport Sciences, 17, 338
  29. 10.1007/BF00690906 · DOI
  30. 10.1016/j.apergo.2009.07.009 · DOI

Cited by

Sorted by citations

Metadata

Authors
Kesler, R. M., Hsiao-Wecksler, E. T., Motl, R. W., Klaren, R. E., Ensari, I., & Horn, G. P.
Venue
Ergonomics
Published
2014-10-17
Volume
58
Issue
1
Pages
148-159
ISSN
  • 0014-0139
  • 1366-5847
Cited by
7
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review