Real-time core body temperature estimation from heart rate for first responders wearing different levels of personal protective equipment
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
First responders often wear personal protective equipment (PPE) for protection from on-the-job hazards. While PPE ensembles offer individuals protection, they limit one's ability to thermoregulate, and can place the wearer in danger of heat exhaustion and higher cardiac stress. Automatically monitoring thermal-work strain is one means to manage these risks, but measuring core body temperature (Tc) has proved problematic. An algorithm that estimates Tc from sequential measures of heart rate (HR) was compared to the observed Tc from 27 US soldiers participating in three different chemical/biological training events (45-90 min duration) while wearing PPE. Hotter participants (higher Tc) averaged (HRs) of 140 bpm and reached Tc around 39 °C. Overall the algorithm had a small bias (0.02 °C) and root mean square error (0.21 °C). Limits of agreement (LoA ± 0.48 °C) were similar to comparisons of Tc measured by oesophageal and rectal probes. The algorithm shows promise for use in real-time monitoring of encapsulated first responders. PRACTITIONER SUMMARY: An algorithm to estimate core temperature (Tc) from non-invasive measures of HR was validated. Three independent studies (n = 27) compared the estimated Tc to the observed Tc in humans participating in chemical/ biological hazard training. The algorithm’s bias and variance to observed data were similar to that found from comparisons of oesophageal and rectal measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Bouchama, A., & Knochel, J. P. (2002) · New England Journal of Medicine · doi:10.1056/nejmra011089 · Cited by 1,898
A non-invasive device to continuously determine heat strain in humans
Gunga, H.-C., Sandsund, M., Reinertsen, R. E., Sattler, F., & Koch, J. (2008) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2008.03.004 · Cited by 129 · cited 2×
“Gunga et al. (2008) developed and tested specialised heat flow sensors, but results varied with ambient temperature.”
BackgroundRationale for a Personal Monitor for Heat Strain
Bernard, T. E., & Kenney, W. L. (1994) · American Industrial Hygiene Association Journal · doi:10.1080/15428119491018772 · Cited by 91
Cited by
Emerging Materials and Strategies for Personal Thermal Management
Hu, R., Liu, Y., Shin, S., Huang, S., Ren, X., Shu, W., Cheng, J., Tao, G., Xu, W., Chen, R., et al. (2020) · Advanced Energy Materials · doi:10.1002/aenm.201903921 · Cited by 638
Graphene Modified Multifunctional Personal Protective Clothing
Bhattacharjee, S., Joshi, R., Chughtai, A. A., & Macintyre, C. R. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201900622 · Cited by 234
Biomarkers and Detection Platforms for Human Health and Performance Monitoring: A Review
Sim, D., Brothers, M. C., Slocik, J. M., Islam, A. E., Maruyama, B., Grigsby, C. C., Naik, R. R., & Kim, S. S. (2022) · Advanced Science · doi:10.1002/advs.202104426 · Cited by 186
Eggenberger, P., MacRae, B. A., Kemp, S., Bürgisser, M., Rossi, R. M., & Annaheim, S. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01780 · Cited by 91
Top 10 research questions related to preventing sudden death in sport and physical activity
Katch, R. K., Scarneo, S. E., Adams, W. M., Armstrong, L. E., Belval, L. N., Stamm, J. M., & Casa, D. J. (2017) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2017.1342201 · Cited by 11
Shourav, M. K., Salsabila, S., Lee, J.-Y., & Kim, J. K. (2021) · Biomedical Optics Express · doi:10.1364/boe.431534 · Cited by 10
Metadata
- Authors
- Buller, M. J., Tharion, W. J., Duhamel, C. M., & Yokota, M.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 2015-05-13
- Volume
- 58
- Issue
- 11
- Pages
- 1830-1841
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W1924062181
- Cited by
- 75
- References
- 4
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.