Effects of industrial back-support exoskeletons on body loading and user experience: an updated systematic review
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
This study is an updated systematic review of papers published in the last 5 years on industrial back-support exoskeletons. The research questions were aimed at addressing the recent findings regarding objective (e.g. body loading, user performance) and subjective evaluations (e.g. user satisfaction), potential side effects, and methodological aspects of usability testing. Thirteen studies of active and twenty of passive exoskeletons were identified. The exoskeletons were tested during lifting and bending tasks, predominantly in laboratory settings and among healthy young men. In general, decreases in participants’ back-muscle activity, peak L5/S1 moments and spinal compression forces were reported. User endurance during lifting and static bending improved, but performance declined during tasks that required increased agility. The overall user satisfaction was moderate. Some side effects were observed, including increased abdominal/lower-limb muscle activity and changes in joint angles. A need was identified for further field studies, involving industrial workers, and reflecting actual work situations. Practitioner summary: Due to increased research activity in the field, a systematic review was performed of recent studies on industrial back-support exoskeletons, addressing objective and subjective evaluations, side effects, and methodological aspects of usability testing. The results indicate the efficiency of exoskeletons in back-load reduction and a need for further studies in real work situations. Abbrevaitions: BB: biceps brachii; BF: biceps femoris; CoM: centre of mass; DA: deltoideus anterior; EMG: electromyography; ES: erector spinae; ES-C: erector spinae-cervical; ESI: erector spinae iliocostalis; ESI-L: erector spinae iliocostalis-lumborum; ESL: erector spinae longissimus; ES-L: erector spinae-lumbar; ESL-L: erector spinae longissimus-lumborum; ESL-T: erector spinae longissimus-thoracis; ES-T: erector spinae-thoracic; GM: glutaeus maximus; LBP: low back pain; LD: latissimus dorsi; LPD: local perceived discomfort scale; LPP: local perceived pressure scale; MS: multifidus spinae; MSD: musculoskeletal disorder; M-SFS: modified spinal function sort; NMV: no mean value provided; OA: obliquus abdominis (internus and externus); OEA: obliquus externus abdominis; OIA : obliquus internus abdominis; RA: rectus abdominis; RF: rectus femoris; RoM: range of motion; SUS: system usability scale; T: trapezius (pars Ascendens and Descendens); TA: trapezius pars ascendens; TC: mid-cervical trapezius; TD: trapezius pars descendens; VAS: visual analog scale; VL: vastus lateralis; VM: vastus medialis
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Dwivedi, Y. K., Rana, N. P., Jeyaraj, A., Clement, M., & Williams, M. D. (2019) · Information Systems Frontiers · doi:10.1007/s10796-017-9774-y · Cited by 2,137
Construction and Evaluation of a User Experience Questionnaire
Laugwitz, B., Held, T., & Schrepp, M. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-89350-9_6 · Cited by 2,114
Exoskeletons for industrial application and their potential effects on physical work load
de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W. (2016) · Ergonomics · doi:10.1080/00140139.2015.1081988 · Cited by 1,062
Self-citationBosch, T., van Eck, J., Knitel, K., & de Looze, M. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.12.003 · Cited by 462
Self-citationHuysamen, K., de Looze, M., Bosch, T., Ortiz, J., Toxiri, S., & O'Sullivan, L. W. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2017.11.004 · Cited by 313
Self-citationBack-Support Exoskeletons for Occupational Use: An Overview of Technological Advances and Trends
Toxiri, S., Näf, M. B., Lazzaroni, M., Fernández, J., Sposito, M., Poliero, T., Monica, L., Anastasi, S., Caldwell, D. G., & Ortiz, J. (2019) · IISE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/24725838.2019.1626303 · Cited by 224
Theurel, J., & Desbrosses, K. (2019) · IISE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/24725838.2019.1638331 · Cited by 203
Mechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties
Gopura, R. A. R. C., & Kiguchi, K. (2009) · 2009 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209630 · Cited by 192
Effects of a passive exoskeleton on the mechanical loading of the low back in static holding tasks
Koopman, A. S., Kingma, I., Faber, G. S., de Looze, M. P., & van Dieën, J. H. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.033 · Cited by 192
Self-citationA passive exoskeleton reduces peak and mean EMG during symmetric and asymmetric lifting
Alemi, M. M., Geissinger, J., Simon, A. A., Chang, S. E., & Asbeck, A. T. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.05.003 · Cited by 189
Toxiri, S., Koopman, A. S., Lazzaroni, M., Ortiz, J., Power, V., de Looze, M. P., O'Sullivan, L., & Caldwell, D. G. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00053 · Cited by 171
Self-citationAlemi, M. M., Madinei, S., Kim, S., Srinivasan, D., & Nussbaum, M. A. (2020) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819897669 · Cited by 170
Industrial exoskeletons: Need for intervention effectiveness research
Howard, J., Murashov, V. V., Lowe, B. D., & Lu, M. (2019) · American Journal of Industrial Medicine · doi:10.1002/ajim.23080 · Cited by 164
Exoskeletons – a review of industrial applications
Bogue, R. W. (2018) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir-05-2018-0109 · Cited by 159
The effect of a passive trunk exoskeleton on metabolic costs during lifting and walking
Baltrusch, S. J., van Dieën, J. H., Bruijn, S. M., Koopman, A. S., van Bennekom, C. A. M., & Houdijk, H. (2019) · Ergonomics · doi:10.1080/00140139.2019.1602288 · Cited by 156
Biomechanical evaluation of a new passive back support exoskeleton
Koopman, A. S., Näf, M. B., Baltrusch, S. J., Kingma, I., Rodriguez‐Guerrero, C., Babič, J., de Looze, M. P., & van Dieën, J. H. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109795 · Cited by 152
Madinei, S., Alemi, M. M., Kim, S., Srinivasan, D., & Nussbaum, M. A. (2020) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819890966 · Cited by 148
Frost, D. M., Abdoli-Eramaki, M., & Stevenson, J. M. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.12.002 · Cited by 137
Koopman, A. S., Kingma, I., de Looze, M. P., & van Dieën, J. H. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109486 · Cited by 124
Madinei, S., Alemi, M. M., Kim, S., Srinivasan, D., & Nussbaum, M. A. (2020) · Applied Ergonomics · doi:10.1016/j.apergo.2020.103156 · Cited by 122
SPEXOR passive spinal exoskeleton decreases metabolic cost during symmetric repetitive lifting
Baltrusch, S. J., van Dieën, J. H., Koopman, A. S., Näf, M. B., Rodriguez‐Guerrero, C., Babič, J., & Houdijk, H. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04284-6 · Cited by 119
Koopman, A. S., Toxiri, S., Power, V., Kingma, I., van Dieën, J. H., Ortiz, J., & de Looze, M. P. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.04.044 · Cited by 111
Abdoli-Eramaki, M., Stevenson, J. M., Reid, S. A., & Bryant, J. T. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.09.006 · Cited by 109
Kim, S., Madinei, S., Alemi, M. M., Srinivasan, D., & Nussbaum, M. A. (2020) · Applied Ergonomics · doi:10.1016/j.apergo.2020.103194 · Cited by 102
Analysis of Exoskeleton Introduction in Industrial Reality: Main Issues and EAWS Risk Assessment
Spada, S., Ghibaudo, L., Gilotta, S., Gastaldi, L., & Cavatorta, M. P. (2017) · International Conference on Applied Human Factors and Ergonomics · doi:10.1007/978-3-319-60825-9_26 · Cited by 97
Impact of two postural assist exoskeletons on biomechanical loading of the lumbar spine
Picchiotti, M. T., Weston, E. B., Knapik, G. G., Dufour, J. S., & Marras, W. S. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.09.006 · Cited by 95
A Real-Time Lift Detection Strategy for a Hip Exoskeleton
Chen, B., Grazi, L., Lanotte, F., Vitiello, N., & Crea, S. (2018) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2018.00017 · Cited by 88
Social Processes: What Determines Industrial Workers’ Intention to Use Exoskeletons?
Elprama, S., Vannieuwenhuyze, J., Bock, S. D., Vanderborght, B., Pauw, K. D., MEEUSEN, R. R., & Jacobs, A. (2020) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819889534 · Cited by 86
Hyun, D. J., Lim, H., Park, S.-I., & Nam, S. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2970448 · Cited by 82
Baltrusch, S. J., Houdijk, H., van Dieën, J. H., & de Kruif, A. J. T. C. M. (2020) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-020-09891-1 · Cited by 81
Reneman, M. F., Brouwer, S., Meinema, A., Dijkstra, P. U., Geertzen, J. H. B., & Groothoff, J. W. (2004) · Journal of Occupational Rehabilitation · doi:10.1023/b:joor.0000047431.40598.47 · Cited by 80
Subject-specific, whole-body models of the stooped posture with a personal weight transfer device
Ulrey, B. L., & Fathallah, F. A. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.08.016 · Cited by 69
A Hip Active Assisted Exoskeleton That Assists the Semi-Squat Lifting
Wei, W., Zha, S., Xia, Y., Gu, J., & Lin, X. (2020) · Applied Sciences · doi:10.3390/app10072424 · Cited by 69
Introduction and Testing of a Passive Exoskeleton in an Industrial Working Environment
Amandels, S., Eyndt, H. O. H., Daenen, L., & Hermans, V. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-96083-8_51 · Cited by 67
Shore, L., Power, V., Hartigan, B., Schülein, S., Graf, E. S., de Eyto, A., & O'Sullivan, L. W. (2019) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819868122 · Cited by 63
Self-citationBackdrivable and Fully-Portable Pneumatic Back Support Exoskeleton for Lifting Assistance
Heo, U., Kim, S. J., & Kim, J. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2969169 · Cited by 63
Miura, K., Kadone, H., Koda, M., Abe, T., Endo, H., Murakami, H., Doita, M., Kumagai, H., Nagashima, K., Fujii, K., et al. (2017) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2017.11.020 · Cited by 59
Baltrusch, S. J., van Dieën, J. H., van Bennekom, C. A. M., & Houdijk, H. (2019) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2019.2954160 · Cited by 51
Tan, C. K., Kadone, H., Miura, K., Abe, T., Koda, M., Yamazaki, M., Sankai, Y., & Suzuki, K. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00142 · Cited by 44
Kozinc, Ž., Baltrusch, S. J., Houdijk, H., & Šarabon, N. (2020) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-020-09899-7 · Cited by 44
The effects of a passive exoskeleton on muscle activity and metabolic cost of energy
Wei, W., Wang, W., Qu, Z., Gu, J., Lin, X., & Yue, C. (2019) · Advanced Robotics · doi:10.1080/01691864.2019.1707708 · Cited by 39
Goršič, M., Regmi, Y., Johnson, A. P., Dai, B., & Novak, D. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2940431 · Cited by 22
Development of support system for forward tilting of the upper body
Kobayashi, H., & Nozaki, H. (2008) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2008.4798779 · Cited by 16
A soft exoskeleton suit to reduce muscle fatigue with pneumatic artificial muscles
Kosuke, T., Ohno, A., Fukuda, Y., Ogawa, K., Tsuji, T., & Kurita, Y. (2018) · Augmented Human International Conference · doi:10.1145/3174910.3174933 · Cited by 14
Cited by
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Ojha, A., Gautam, Y., Jebelli, H., & Akanmu, A. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105742 · Cited by 39
Metadata
- Authors
- Kermavnar, T., de Vries, A. W., de Looze, M. P., & O’Sullivan, L. W.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 2021-03-16
- Volume
- 64
- Issue
- 6
- Pages
- 685-711
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W3116409808
- Cited by
- 275
- References
- 45
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.