The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Mechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties
Abstract
Active upper-limb exoskeleton robots have been developing from 1960s. In recent years, the mechanical designs and control algorithms of active upper-limb exoskeleton robots were developed significantly. This paper reviews the state-of-the-art of active upper-limb exoskeleton robots that are applied in the areas of rehabilitation and assistive robotics. In addition, the main requirements of the active upper-limb exoskeleton robot are identified and the mechanical designs of existing active upper-limb exoskeleton robot are classified. The design difficulties of an active upper-limb exoskeleton robot are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training
Tsagarakis, N. G., & Caldwell, D. G. (2003) · Autonomous Robots · doi:10.1023/a:1024484615192 · Cited by 335
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159
Self-citationRehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87
Cited by
Exoskeletons for industrial application and their potential effects on physical work load
de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W. (2016) · Ergonomics · doi:10.1080/00140139.2015.1081988 · Cited by 1,062
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
A Review on Design of Upper Limb Exoskeletons
Gull, M. A., Bai, S., & Bak, T. (2020) · Robotics · doi:10.3390/robotics9010016 · Cited by 435
Active Exoskeleton Control Systems: State of the Art
Anam, K., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.273 · Cited by 304
Metadata
- Authors
- Gopura, R. A. R. C., & Kiguchi, K.
- Venue
- 2009 IEEE International Conference on Rehabilitation Robotics
- Publisher
- IEEE
- Published
- 2009-06
- Pages
- 178-187
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W2139214287
- Cited by
- 192
- References
- 3
- FWCI
- 16.69
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties. https://app.cochat.ai/papers/10.1109/icorr.2009.5209630
- The paper
- Gopura, R. A. R. C., & Kiguchi, K. (2009). Mechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties. 2009 IEEE International Conference on Rehabilitation Robotics. https://doi.org/10.1109/icorr.2009.5209630
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.