Audibility and identification of auditory alarms in the operating room and intensive care unit
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The audibility and the identification of 23 auditory alarms in the intensive care unit (ICU) and 26 auditory alarms in the operating rooms (ORs) of a 214-bed Canadian teaching hospital were investigated. Digital tape recordings of the alarms were made and analysed using masked-threshold software developed at the Université de Montréal. The digital recordings were also presented to the hospital personnel responsible for monitoring these alarms on an individual basis in order to determine how many of the alarms they would be able to identify when they heard them. Several of the alarms in both areas of the hospital could mask other alarms in the same area, and many of the alarms in the operating rooms could be masked by the sound of a surgical saw or a surgical drill. The staff in the OR (anaesthetists, anaesthesia residents, and OR technologists) were able to identify a mean of between 10 and 15 of the 26 alarms found in their operating theatres. The ICU nurses were able to identify a mean of between 9 and 14 of the 23 alarms found in their ICU. Alarm importance was positively correlated with the frequency of alarm identification in the case of the OR, rho = 0.411, but was not significantly correlated in the case of the ICU, rho = 0.155. This study demonstrates the poor design of auditory warning signals in hospitals and the need for standardization of alarms on medical equipment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human factors in engineering and design
Asfour, S. S. (1988) · International Journal of Industrial Ergonomics · doi:10.1016/0169-8141(88)90028-5 · Cited by 1,807
Human Factors in Engineering and Design
Sanders, M. S., & McCormick, E. J. (1957) · Medical Entomology and Zoology · Cited by 1,572
The Journal of General Psychology
B., E. G., Titchener, E. B., & Murchison, C. (1928) · The American Journal of Psychology · doi:10.2307/1414495 · Cited by 649
Human engineering guide to equipment design.
(1963) · McGraw-Hill Book Company · doi:10.1037/13113-000 · Cited by 481
Edworthy, J., Loxley, S., & Dennis, I. (1991) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872089103300206 · Cited by 432
Foundations of modern auditory theory
Thornton, A. R. D. (1972) · Journal of Sound and Vibration · doi:10.1016/0022-460x(72)90489-0 · Cited by 373
Localization of sound in rooms
Hartmann, W. M. (1983) · The Journal of the Acoustical Society of America · doi:10.1121/1.390163 · Cited by 303
A model of loudness summation.
Zwicker, E., & Scharf, B. (1965) · Psychological Review · doi:10.1037/h0021703 · Cited by 298
Focused auditory attention and frequency selectivity
Scharf, B., Quigley, S., Aoki, C., Peachey, N., & Reeves, A. (1987) · Perception & Psychophysics · doi:10.3758/bf03203073 · Cited by 190
Localization of sound in rooms, III: Onset and duration effects
Rakerd, B., & Hartmann, W. M. (1986) · The Journal of the Acoustical Society of America · doi:10.1121/1.394282 · Cited by 173
Auditory warning sounds in the work environment
Patterson, R. D. (1990) · Philosophical Transactions of the Royal Society of London. B, Biological Sciences · doi:10.1098/rstb.1990.0091 · Cited by 169
Survey of alarms in an intensive therapy unit*
O'CARROLL, T. M. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12844.x · Cited by 117
Auditory Alarms during Anesthesia Monitoring
Kestin, I. G., Miller, B. R., & Lockhart, C. H. (1988) · Anesthesiology · doi:10.1097/00000542-198807000-00018 · Cited by 110
An “Alarming” situation in the intensive therapy unit
Kerr, J., & Hayes, B. (1983) · Intensive Care Medicine · doi:10.1007/bf01772574 · Cited by 51
Berlyne, D. E., McDonnell, P. M., Nicki, R. M., et al. (1967) · Canadian Journal of Psychology/Revue Canadienne de Psychologie · doi:10.1037/h0082987 · Cited by 33
Cited by
Wahr, J. A., Prager, R. L., Abernathy, J. H., Martinez, E. A., Salas, E., Seifert, P. C., Groom, R. C., Spiess, B. D., Searles, B. E., Sundt, T. M., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182a38efa · Cited by 334
Poor prognosis for existing monitors in the intensive care unit
Tsien, C. L., & Fackler, J. C. (1997) · Critical Care Medicine · doi:10.1097/00003246-199704000-00010 · Cited by 309
The hostile environment of the intensive care unit
Donchin, Y., & Seagull, F. J. (2002) · Current Opinion in Critical Care · doi:10.1097/00075198-200208000-00008 · Cited by 297
Alarm Algorithms in Critical Care Monitoring
Imhoff, M., & Kuhls, S. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000204385.01983.61 · Cited by 266
Alarms and human behaviour: implications for medical alarms
Edworthy, J., & Hellier, E. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael114 · Cited by 185
Metadata
- Authors
- MOMTAHAN, K., HÉTU, R., & TANSLEY, B.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1993-10
- Volume
- 36
- Issue
- 10
- Pages
- 1159-1176
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W1986434308
- Cited by
- 168
- References
- 15
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.