The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Poor prognosis for existing monitors in the intensive care unit
Abstract
OBJECTIVE: To identify areas requiring the most urgent improvement in the intensive care unit (ICU); and to accurately determine the positive predictive value of routine critical care patient monitoring alarms, as well as the common causes for false-positive alarms. DESIGN: Prospective, observational study. SETTING: A multidisciplinary ICU in a university-affiliated children's hospital (excluding children with primary heart disease). INTERVENTIONS: The occurrence rate, cause, and appropriateness of all alarms from tracked monitors were recorded by a trained observer and validated by the bedside nurse over a 10-wk period for a single bedspace at a time. MEASUREMENTS AND MAIN RESULTS: After 298 monitored hrs, 86% of a total 2,942 alarms were found to be false-positive alarms, while an additional 6% were classified as clinically irrelevant true alarms. Only 8% of all alarms tracked during the study period were determined to be true alarms with clinical significance. Alarms were also classified according to whether they were clearly associated with a "patient intervention" (18%), were clearly not associated with a patient intervention (74%), or had unclear association to interventions (8%). While 11% of "nonpatient intervention" alarms were clinically significant true alarms, only 2% of "patient intervention" alarms were so. Positive predictive values for the various devices ranged from < 1% for the pulse oximeter's heart rate signal to 74% for the arterial catheter's mean systemic blood pressure signal during periods free from patient interventions. The pulse oximeter caused false-positive alarms most frequently, with common reasons being bad data format/bad connection and poor contact. CONCLUSION: Efforts to develop intelligent monitoring systems have more potential to deliver significantly improved patient care by initially targeting especially weak areas in ICU monitoring, such as pulse oximetry reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Research works printed but not linked: 12
- Koski, 1990, Int J Clin Monit Comput, 7, 129, 10.1007/BF01724206 · DOI
- O'Carroll, 1986, Anaesthesia, 41, 742, 10.1111/j.1365-2044.1986.tb12844.x · DOI
- Meredith, 1995, J Adv Nurs, 21, 15, 10.1046/j.1365-2648.1995.21010015.x · DOI
- Sara, 1986, Anaesth Intensive Care, 14, 448, 10.1177/0310057X8601400421 · doi:10.1177/0310057x8601400421
- Momtahan, 1993, Ergonomics, 36, 1159, 10.1080/00140139308967986 · DOI · Paper page
- Finley, 1991, Can J Anaesth, 38, 958, 10.1007/BF03008611 · doi:10.1007/bf03008611
- Makivirta, 1991, Comput Methods Programs Biomed, 34, 139, 10.1016/0169-2607(91)90039-V · DOI
- Crew, 1991, Intensive Care Med, 17, 359, 10.1007/BF01716197 · doi:10.1007/bf01716197
- Koski, 1992, Int J Clin Monit Comput, 8, 289, 10.1007/BF01739130 · doi:10.1007/bf01739130
- Koski, 1994, Int J Clin Monit Comput, 11, 79, 10.1007/BF01259556 · DOI
- Fukui, 1989, J Clin Monit, 5, 211, 10.1007/BF01627458 · doi:10.1007/bf01627458
- Beneken, 1989, J Clin Monit, 5, 205, 10.1007/BF01627457 · DOI
Cited by
Sendelbach, S., & Funk, M. (2013) · AACN Advanced Critical Care · doi:10.4037/nci.0b013e3182a903f9 · Cited by 497
Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms
Graham, K. C., & Cvach, M. (2010) · American Journal of Critical Care · doi:10.4037/ajcc2010651 · Cited by 459
Machine Learning and Decision Support in Critical Care
Johnson, A. E. W., Ghassemi, M. M., Nemati, S., Niehaus, K. E., Clifton, D., & Clifford, G. D. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2501978 · Cited by 432
Jubran, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2399-x · Cited by 401
Orphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Metadata
- Authors
- Tsien, C. L., & Fackler, J. C.
- Venue
- Critical Care Medicine
- Published
- 1997-04
- Volume
- 25
- Issue
- 4
- Pages
- 614-619
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2002971490
- Cited by
- 309
- References
- 1
- FWCI
- 8.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Poor prognosis for existing monitors in the intensive care unit. https://app.cochat.ai/papers/10.1097/00003246-199704000-00010
- The paper
- Tsien, C. L., & Fackler, J. C. (1997). Poor prognosis for existing monitors in the intensive care unit. Critical Care Medicine. https://doi.org/10.1097/00003246-199704000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.