On the robust fault detection via a sliding mode disturbance observer
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
This paper deals with robust fault detection for non-linear systems. This problem is usually solved by designing an observable subsystem which is only affected by the fault and not by the control and disturbance inputs. However, such a subsystem may not exist so that the so-called fundamental problem of residual generation (FPRG) is not solvable. The aim of the present paper is to design a fault detection filter when the conditions for the existence of a solution to the non-linear FPRG are not satisfied. Our approach is made in a geometric context. Under some decoupling assumptions, the design of sliding mode observers allows us to reconstruct the disturbance inputs and then to generate an effective residual. An illustrative example is given throughout the paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isidori, A. (1995) · Communications and Control Engineering · doi:10.1007/978-1-84628-615-5 · Cited by 6,755
Sliding Modes in Control and Optimization
Utkin, V. I. (1992) · Springer eBooks · doi:10.1007/978-3-642-84379-2 · Cited by 6,684
Fault diagnosis in dynamic systems using analytical and knowledge-based redundancy
Frank, P. M. (1990) · Automatica · doi:10.1016/0005-1098(90)90018-d · Cited by 3,545 · cited 2×
“Fault detection and isolation (FDI) has been widely investigated using various methods (Willsky 1976, Chow and Willsky 1984, Frank 1990, Staroswiecki et al. 1993, Hammouri et al. 1998, Commault 1999, Frank et al. 1999).”
MethodNonlinear controllability and observability
Hermann, R., & Krener, A. (1977) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1977.1101601 · Cited by 2,374 · cited 3×
“…n dlg ð18Þ and since condition B4 implies that dLi~f2 ~h2ðz2Þ ~p2ðz2Þ ¼ 0 for all i 2 f0, . . . , n dl 2g, one obtains exactly the triangular observable form (16) and (17) œ Remark 3: The condition B2 means that the subsystem (13) and (14) is locally weakly observable (Hermann and Krener, 1977).”
BackgroundInfluentialA survey of design methods for failure detection in dynamic systems
Willsky, A. S. (1976) · Automatica · doi:10.1016/0005-1098(76)90041-8 · Cited by 2,153
Analytical redundancy and the design of robust failure detection systems
Chow, E., & Willsky, A. S. (1984) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1984.1103593 · Cited by 1,622 · cited 1×
“Fault detection and isolation (FDI) has been widely investigated using various methods (Willsky 1976, Chow and Willsky 1984, Frank 1990, Staroswiecki et al. 1993, Hammouri et al. 1998, Commault 1999, Frank et al. 1999).”
MethodA survey of design methods for failure detection in dynamic systems
(1977) · Microelectronics Reliability · doi:10.1016/0026-2714(77)90326-2 · Cited by 1,421
Sliding mode observers for fault detection and isolation
Edwards, C., Spurgeon, S. K., & Patton, R. J. (2000) · Automatica · doi:10.1016/s0005-1098(99)00177-6 · Cited by 1,343
Sliding Mode Control In Engineering
Perruquetti, W., & Barbot, J.-P. (2002) · CRC Press eBooks · doi:10.1201/9780203910856 · Cited by 1,166 · cited 4×
“The generalization of the following proposition for multi-output systems can be found in Chapter 4 in Perruquetti and Barbot (2002).”
BackgroundInfluentialSelf-citation1985 IEEE conference on decision and control
(1985) · IEEE Control Systems Magazine · doi:10.1109/mcs.1985.1104966 · Cited by 982
The invariance conditions in variable structure systems
Draženović, B. (1969) · Automatica · doi:10.1016/0005-1098(69)90071-5 · Cited by 935
Design of unknown input observers and robust fault detection filters
CHEN, J., PATTON, R. J., & ZHANG, H.-Y. (1996) · International Journal of Control · doi:10.1080/00207179608921833 · Cited by 835 · cited 1×
“Here, we are much concerned with the problem of robust fault detection based on observers (Frank 1994, Hou and Müller 1994, Chen et al. 1996, Kinnaert 1999).”
BackgroundA geometric approach to nonlinear fault detection and isolation
De Persis, C., & Isidori, A. (2001) · IEEE Transactions on Automatic Control · doi:10.1109/9.928586 · Cited by 806 · cited 4×
“A necessary condition has been given recently in the work of de Persis and Isidori (2001).”
BackgroundMethodInfluentialFailure detection and identification
Massoumnia, M.-A., Verghese, G. C., & Willsky, A. S. (1989) · IEEE Transactions on Automatic Control · doi:10.1109/9.16422 · Cited by 588 · cited 2×
“It was first formulated for linear systems by Massoumnia et al. (1989) who gave a necessary and sufficient condition for solving this problem: the existence of an unobservability subspace leading to an observable subsystem unaffected by all fault signals but one.”
BackgroundThe peaking phenomenon and the global stabilization of nonlinear systems
Sussmann, H. J., & Kokotović, P. V. (1991) · IEEE Transactions on Automatic Control · doi:10.1109/9.75101 · Cited by 530 · cited 1×
“Thus, at each step, a sub-dynamics of dimension one is obtained and consequently no peaking phenomena appear (Sussmann and Kokotovic 1991).”
BackgroundEnhancement of robustness in observer-based fault detection†
Frank, P. M. (1994) · International Journal of Control · doi:10.1080/00207179408923112 · Cited by 367 · cited 1×
“Here, we are much concerned with the problem of robust fault detection based on observers (Frank 1994, Hou and Müller 1994, Chen et al. 1996, Kinnaert 1999).”
BackgroundFault detection and isolation observers
Hou, M., & Müller, P. C. (1994) · International Journal of Control · doi:10.1080/00207179408921497 · Cited by 193 · cited 1×
“Here, we are much concerned with the problem of robust fault detection based on observers (Frank 1994, Hou and Müller 1994, Chen et al. 1996, Kinnaert 1999).”
BackgroundFault-diagnosis by disturbance decoupled nonlinear observers
Seliger, R., & Frank, P. M. (2002) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.1991.261547 · Cited by 193 · cited 1×
“This disturbance decoupling approach has also been considered in the case of non-linear systems (Seliger and Frank 1991, de Persis and Isidori 1999).”
MethodFault Detection and Isolation for State Affine Systems
Hammouri, H., Kinnaert, M., & Yaagoubi, E. H. E. (1998) · European Journal of Control · doi:10.1016/s0947-3580(98)70095-0 · Cited by 62 · cited 1×
“Fault detection and isolation (FDI) has been widely investigated using various methods (Willsky 1976, Chow and Willsky 1984, Frank 1990, Staroswiecki et al. 1993, Hammouri et al. 1998, Commault 1999, Frank et al. 1999).”
MethodNonlinear observers for fault detection and isolation
Frank, P. M., Schrier, G., & García, E. A. (2007) · Springer eBooks · doi:10.1007/bfb0109937 · Cited by 45 · cited 1×
“Fault detection and isolation (FDI) has been widely investigated using various methods (Willsky 1976, Chow and Willsky 1984, Frank 1990, Staroswiecki et al. 1993, Hammouri et al. 1998, Commault 1999, Frank et al. 1999).”
MethodPersis, C. D., & Isidori, A. (1999) · European Control Conference (ECC) · doi:10.23919/ecc.1999.7099695 · Cited by 29 · cited 1×
“This disturbance decoupling approach has also been considered in the case of non-linear systems (Seliger and Frank 1991, de Persis and Isidori 1999).”
MethodOn the problem of fault detection and residual generation
Djemaï, M., Barbot, J. P., & Béthoux, O. (2002) · Proceedings of the IEEE Conference on Decision & Control, including the Symposium on Adaptive Processes · doi:10.1109/cdc.2001.914585 · Cited by 8
Self-citation
Cited by
Zhang, X., Polycarpou, M. M., & Parisini, T. (2010) · Automatica · doi:10.1016/j.automatica.2009.11.014 · Cited by 346
On sliding mode observers for systems with unknown inputs
Floquet, T., Edwards, C., & Spurgeon, S. K. (2007) · International Journal of Adaptive Control and Signal Processing · doi:10.1002/acs.958 · Cited by 263
Self-citationReview and classification of recent observers applied in chemical process systems
Mohd Ali, J., Ha Hoang, N., Hussain, M. A., & Dochain, D. (2015) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2015.01.019 · Cited by 239
“…al., 2009; Busawon and Leon-Morales, 2000; Assis and Filho, 2000; Ciccio et al., 2011; Dong and Yang, 2011; Farza et al., 1997; Farza et al., 2011; Floquet et al., 2004; Hashimoto et al., 2000; Kalsi et al., 2009; Kazantzis and Kravaris, 2001; Kazantzis et al., 2000; Ko and Wang, 2007; Kravaris…”
BackgroundThe Smooth Variable Structure Filter
Habibi, S. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.893255 · Cited by 223
Floquet, T., & Barbot, J. P. (2007) · International Journal of Systems Science · doi:10.1080/00207720701409330 · Cited by 213
Self-citation
Metadata
- Authors
- Floquet *, T., Barbot, J. P., Perruquetti, W., & Djemai, M.
- Venue
- International Journal of Control
- Publisher
- Informa UK Limited
- Published
- 2004-05-10
- Volume
- 77
- Issue
- 7
- Pages
- 622-629
- ISSN
- 0020-7179 (ISSN-L)
- 1366-5820
- OpenAlex
- W2096837771
- Cited by
- 162
- References
- 22
- FWCI
- 21.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.