VALIDITY OF AMBULATORY ACCELEROMETRY TO QUANTIFY PHYSICAL ACTIVITY IN HEART FAILURE
The DOI matches its Crossref record.
Abstract
The purpose was to assess the validity of a novel Activity Monitor to quantify physical activity in congestive heart failure. The Activity Monitor is based on long-term ambulatory monitoring of signals from body-fixed accelerometers. Information can be obtained on which mobility-related activity is performed, when, how intense, and for how long. Ten patients performed several functional activities. Continuous registrations of accelerometer signals were made and the output was compared with visual analysis of simultaneously made video recordings (reference method). Overall results showed an agreement between both methods of 90%. Percentages of sensitivity and predictive value were higher than 80% for most activities. Overall number of transitions was determined well (Activity Monitor, 153; video, 149; p = 0.33). It was concluded that the Activity Monitor is a valid instrument to quantify several aspects of everyday physical activity in congestive heart failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Characteristics of physical activities in daily life in chronic obstructive pulmonary disease
Pitta, F., Troosters, T., Spruit, M. A., Probst, V. S., Decramer, M., & Gosselink, R. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200407-855oc · Cited by 1,256
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
Measuring daily behavior using ambulatory accelerometry: The Activity Monitor
Bussmann, J. B. J., Martens, W. L. J., Tulen, J. H. M., Schasfoort, F. C., van den Berg-Emons, H. J. G., & Stam, H. J. (2001) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03195388 · Cited by 315
Accelerometers in rehabilitation medicine for older adults
Culhane, K. M., O’Connor, M., Lyons, D., & Lyons, G. M. (2005) · Age and Ageing · doi:10.1093/ageing/afi192 · Cited by 302
A description of an accelerometer-based mobility monitoring technique
Lyons, G. M., Culhane, K. M., Hilton, D., Grace, P. A., & Lyons, D. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.11.006 · Cited by 218
Dalal, H. M., Taylor, R. S., Jolly, K., Davis, R. C., Doherty, P., Miles, J., van Lingen, R., Warren, F. C., Green, C., Wingham, J., et al. (2019) · European Journal of Preventive Cardiology · doi:10.1177/2047487318806358 · Cited by 169
“Aldosterone antagonist Digoxin 64 (60) 20 (19) 52 (48) 14 (13)”
Cowie, A., Thow, M. K., Granat, M. H., & Mitchell, S. L. (2011) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1177/1741826710389389 · Cited by 59
Interictal daily functioning in migraine
Stronks, D., Tulen, J., Bussmann, J., Mulder, L., & Passchier, J. (2004) · Cephalalgia · doi:10.1111/j.1468-2982.2004.00661.x · Cited by 51
Sánchez, M., Bussmann, J., Janssen, W., Horemans, H., Chastin, S., Heijenbrok, M., & Stam, H. (2015) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-1994 · Cited by 37
Metadata
- Authors
- J. G. van den Berg-Emons, J.
- Venue
- Scandinavian Journal of Rehabilitation Medicine
- Publisher
- Informa UK Limited
- Published
- 2000-11-30
- Volume
- 32
- Issue
- 4
- Pages
- 187-192
- ISSN
- 0036-5505 (ISSN-L)
- OpenAlex
- W2074934214
- Cited by
- 87
- References
- 0
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.