Quality Control of SMBG in Clinical Practice

Solnica, Bogdan, Naskalski, Jerzy W. · 2005 · Scandinavian Journal of Clinical and Laboratory Investigation
Cited by 24

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

We present results of quality control of self-monitored blood glucose (SMBG) performed in diabetes outpatient clinic. The tests included: inspection of glucose meter, blood glucose self-measurement by a patient, glucose measurement by point-of-care analyzer used in a clinic and with the laboratory method. In the study 158 glucose meters were controlled and compared with HemoCue glucose analyzer used in the clinic as the reference. 122 glucose meters readings were also compared with the reference laboratory method. Tested glucose meters included: Accutrend {18}, Glucotrend {59}, Precision QiD {39}, One Touch {26} and Glucocard II {16}. Reference glucose assays were performed using glucose oxidase method on Hitachi 911 analyzer. Glucose concentrations measured by the controlled glucose meters ranged from 36 to 425 mg/dL. The analytical bias of the glucose meters amounted from 2.48% to 8.27%. Correlation coefficient between results obtained by the tested glucose meters and HemoCue analyzer ranged from 0.957 to 0.980 and between glucose meters and laboratory method from 0.955 to 0.985. Passing-Bablok agreement test and Deming regression analysis indicated good concordance of results between all the tested glucose meters and HemoCue analyzer, whereas good agreement with the laboratory method was found for Accutrend, Glucotrend, Precision QiD and One Touch glucose meters. In conclusion, good analytical performance of the employed glucose meters and a bias less than 10% from the reference values were found. Results of this study show the possibility for routine, convenient for the patient quality control of SMBG in an outpatient clinic.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00365510500235996

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 24

Metadata

Authors
Solnica, B., & Naskalski, J. W.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
2005-01
Volume
65
Issue
sup240
Pages
80-85
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W1974583249
Cited by
24
References
4
FWCI
2.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality Control of SMBG in Clinical Practice. https://app.cochat.ai/papers/10.1080/00365510500235996
The paper
Solnica, B., & Naskalski, J. W. (2005). Quality Control of SMBG in Clinical Practice. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365510500235996

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.