Blood and plasma volumes determined by carbon monoxide gas, 99m Tc-labelled erythrocytes, 125 I-albumin and the T 1824 technique
The DOI matches its Crossref record.
Abstract
The total amount of circulating haemoglobin was measured in 12 subjects using a direct carbon monoxide (CO)-technique. O2 plus 50 ml CO gas was rebreathed in a small closed system for 10 min. Carboxyhaemoglobin (HbCO)% was measured with a diode-array spectrophotometer before and after the rebreathing. delta HBCO% and the amount of CO in moles (nCO) were used to calculate the total amount of circulating haemoglobin. Blood volume was calculated by dividing this figure with the haemoglobin concentration and plasma volume by multiplying the blood volume with 1-haematocrit. The calculated blood and plasma volumes were compared with the simultaneously measured volumes by 99mTc-labelled erythrocytes, 125I-albumin and T 1824 (Evans Blue). Mean blood volume determined with CO was 4557 ml (3251-6576 ml) compared with 4527 ml (3390-6527 ml) with 99mTc-labelled erythrocytes (r = 0.97). Mean plasma volume by T 1824 was 2895 ml (1972-3658 ml) vs 2898 ml (1815-3714) ml using 125I-albumin, (r = 0.99). The plasma volumes calculated from the blood volumes determined by the erythrocyte-labelling methods were 5-10% lower than those measured with labelled albumin. There was a better correlation between the plasma volumes by the albumin methods and by the CO-technique (r = 0.98 and r = 0.97, respectively) than between the plasma volumes by the albumin methods and by 99mTc-erythrocytes (r = 0.90 and r = 0.87, respectively).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 13
- Grehant M, 1882, C R Acad Sci (Paris], 94, 1450
- Sjöstrand T, 1948, Acta Physiol Scand, 16, 211, 10.1111/j.1748-1716.1948.tb00540.x · DOI · Paper page
- Katchmann B J, 1967, Clin Chem, 13, 877, 10.1093/clinchem/13.10.877 · doi:10.1093/clinchem/13.10.877
- Godin G, 1972, Respiration, 29, 317, 10.1159/000192905 · DOI
- Fogh-Andersen N, 1987, Clin Chim Acta, 166, 283, 10.1016/0009-8981(87)90431-1 · doi:10.1016/0009-8981(87)90431-1
- Kelbæk H, 1989, Eur J Nucl Med, 15, 333, 10.1007/BF00449219 · doi:10.1007/bf00449219
- Nielsen M H, 1962, Scand J Clin Lab Invest, 6, 605, 10.3109/00365516209051291 · doi:10.3109/00365516209051291
- Mollison. Blood Transfusion in Clinical Medicine, 7th edn. Blackwell Scientific Publications, Oxford 1983; 65–70
- Blackmore D J, 1970, Nature, 227, 386, 10.1038/227386a0 · doi:10.1038/227386a0
- Luomanmäki K, 1966, Ann Med Ex Fenn, 44, 21
- Sjöstrand T, 1953, Physiol Rev, 33, 202, 10.1152/physrev.1953.33.2.202 · DOI · Paper page
- Fåhreaus R, 1929, Physiol Rev, 9, 241, 10.1152/physrev.1929.9.2.241 · DOI · Paper page
- Bent-Hansen L, 1989, Acta Physiol Scand, 136, 455, 10.1111/j.1748-1716.1989.tb08687.x · doi:10.1111/j.1748-1716.1989.tb08687.x
Cited by
Red blood cells in sports: Effects of exercise and training on oxygen supply by red blood cells
Mairbäurl, H. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00332 · Cited by 482
Subnormal norepinephrine release relates to presyncope in astronauts after spaceflight
Fritsch-Yelle, J. M., Whitson, P. A., Bondar, R. L., & Brown, T. E. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.5.2134 · Cited by 238
Waters, W. W., Ziegler, M. G., & Meck, J. V. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00544.2001 · Cited by 232
Hemoglobin mass and intravascular volume kinetics during and after exposure to 3,454-m altitude
Siebenmann, C., Cathomen, A., Hug, M., Keiser, S., Lundby, A. K., Hilty, M. P., Goetze, J. P., Rasmussen, P., & Lundby, C. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01121.2014 · Cited by 128
Otto, J. M., Plumb, J. O. M., Clissold, E., Kumar, S. B., Wakeham, D. J., Schmidt, W., Grocott, M. P. W., Richards, T., & Montgomery, H. E. (2017) · Haematologica · doi:10.3324/haematol.2017.169680 · Cited by 93
“late 1800s, with refined techniques being published 100 years later.(20) In 2005, Schmidt and Prommer reported a simpler and”
Method
Metadata
- Authors
- Thomsen, J. K., Fogh-Andersen, N., Bulow, K., & Devantier, A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1991-01
- Volume
- 51
- Issue
- 2
- Pages
- 185-190
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2018794235
- Cited by
- 88
- References
- 0
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood and plasma volumes determined by carbon monoxide gas, 99m Tc-labelled erythrocytes, 125 I-albumin and the T 1824 technique. https://app.cochat.ai/papers/10.1080/00365519109091106
- The paper
- Thomsen, J. K., Fogh-Andersen, N., Bulow, K., & Devantier, A. (1991). Blood and plasma volumes determined by carbon monoxide gas, 99m Tc-labelled erythrocytes, 125 I-albumin and the T 1824 technique. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365519109091106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.