The DOI matches its Crossref record.
Determination of Gastrin in Serum: An Evaluation of the Reliability of a Radioimmunoassay
Abstract
Stadil, Flemming & Rehfeld, Jens F. 1973. Determination of Gastrin in Serum. An Evaluation of the Reliability of a Radioimmunoassay. Scand. J. Gastroent. 8, 101-112.In view of conflicting results of gastrin determination, a radioimmunoassay technique has been evaluated in detail. Free and bound hormone was separated by anionic exchange resins, uncoated charcoal, or polyethylene glycol. Similar results were obtained for the three methods. Heparin, sodium chloride, and protein influenced the determinations. The reliability of the assay was investigated by recovery experiments, dilution experiments, experiments with mixtures of sera, and by determinations using antisera raised against different antigens. After an overnight fast, mean concen-trations of gastrin (in pmole per 1 serum, ± S.E.M. or range) were 24 ± 2.1 in 120 normal subjects, 23 ± 1.1 in 103 patients with duodenal idcer, 27 ± 2.8 in 19 patients with prepyloric ulcer, 415 (14-1705) in 36 patients with pernicious anaemia, and 4987 (123-61360) in 11 patients with the Zollinger-Ellison syndrome. No difference was found between normal subjects and duodenal ulcer patients of the same age, nor between males and females. There was no general tendency for gastrin concentrations to increase with age.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New peptide in the vertebrate CNS reacting with antigastrin antibodies
VANDERHAEGHEN, J. J., SIGNEAU, J. C., & GEPTS, W. (1975) · Nature · doi:10.1038/257604a0 · Cited by 758
Truncated GLP-1 (proglucagon 78?107-amide) inhibits gastric and pancreatic functions in man
Wettergren, A., Schjoldager, B., Mortensen, P. E., Myhre, J., Christiansen, J., & Holst, J. J. (1993) · Digestive Diseases and Sciences · doi:10.1007/bf01316798 · Cited by 670
Wettergren, A., Petersen, H., ørskov, C., Christiansen, J., Sheikh, S. P., & Holst, J. J. (1994) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365529409092462 · Cited by 133
Radioimmunoassay of cholecystokinin-pancreozymin
Harvey, R. F., Dowsett, L., Hartog, M., & Read, A. E. (1974) · Gut · doi:10.1136/gut.15.9.690 · Cited by 64
The role of GLP-1 in the postprandial effects of acarbose in type 2 diabetes
Dalsgaard, N. B., Gasbjerg, L. S., Hansen, L. S., Hansen, N. L., Stensen, S., Hartmann, B., Rehfeld, J. F., Holst, J. J., Vilsbøll, T., & Knop, F. K. (2021) · European Journal of Endocrinology · doi:10.1530/eje-20-1121 · Cited by 37
Self-citation
Metadata
- Authors
- Stadil, F., & Rehfeld, J. F.
- Venue
- Scandinavian Journal of Gastroenterology
- Publisher
- Informa UK Limited
- Published
- 1973-03-20
- Volume
- 8
- Issue
- 2
- Pages
- 101-112
- ISSN
- 0036-5521 (ISSN-L)
- 1502-7708
- OpenAlex
- W3187006588
- Cited by
- 197
- References
- 0
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Gastrin in Serum: An Evaluation of the Reliability of a Radioimmunoassay. https://app.cochat.ai/papers/10.1080/00365521.1973.12096677
- The paper
- Stadil, F., & Rehfeld, J. F. (1973). Determination of Gastrin in Serum: An Evaluation of the Reliability of a Radioimmunoassay. Scandinavian Journal of Gastroenterology. https://doi.org/10.1080/00365521.1973.12096677
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.