Indentation modulus of elastically anisotropic half spaces
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The unloading process in an indentation experiment is often modelled as a contact problem of a rigid punch on an elastically isotropic half space. This allows one to derive simple formulae to determine the indentation modulus from experimental data. We have studied the contact problem of a flat circular punch and a paraboloid on an elastically anisotropic half space and have shown that the formulae used for isotropic materials can be used for anisotropic materials as long as the half space has three or fourfold rotational symmetry. In the case of lower symmetry, the indentation modulus depends on the shape of the indenter. We have calculated the indentation modulus of {100}, {111} and {110} surfaces of cubic crystals for a wide range of elastic constants. The {110} indentation modulus was calculated for the case of a flat circular punch. The single-crystal indentation moduli differ substantially from the isotropic polycrystalline indentation moduli and the differences increase with increasing anisotropy factor and decreasing (100) Poisson's ratio. The indentation modulus of a polycrystalline cubic material with a (111) fibre texture in the direction of the indentation has also been calculated and is much larger than the {111} modulus of the corresponding single crystal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oliver, W. C., & Pharr, G. M. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.1564 · Cited by 26,961
Sneddon, I. N. (1965) · International Journal of Engineering Science · doi:10.1016/0020-7225(65)90019-4 · Cited by 4,346
A method for interpreting the data from depth-sensing indentation instruments
Doerner, M. F., & Nix, W. D. (1986) · Journal of Materials Research · doi:10.1557/jmr.1986.0601 · Cited by 2,863
Self-citationPharr, G. M., Oliver, W. C., & Brotzen, F. R. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.0613 · Cited by 1,562
A variational approach to the theory of the elastic behaviour of polycrystals
Hashin, Z., & Shtrikman, S. (1962) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(62)90005-4 · Cited by 1,094
Cited by
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Measuring the elastic properties of anisotropic materials by means of indentation experiments
Vlassak, J. J., & Nix, W. D. (1994) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(94)90033-7 · Cited by 551
Self-citationLocal elastic properties of a metallic glass
Wagner, H., Bedorf, D., Küchemann, S., Schwabe, M., Zhang, B., Arnold, W., & Samwer, K. (2011) · Nature Materials · doi:10.1038/nmat3024 · Cited by 433
Elastic properties of microstructural components of human bone tissue as measured by nanoindentation
Rho, J.-Y., Roy, M. E., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199904)45:1<48::aid-jbm7>3.0.co;2-5 · Cited by 348
Elastic and plastic properties of thin films on substrates: nanoindentation techniques
D. Nix, W. (1997) · Materials Science and Engineering: A · doi:10.1016/s0921-5093(97)00176-7 · Cited by 324
Kalidindi, S. R., & Pathak, S. (2008) · Acta Materialia · doi:10.1016/j.actamat.2008.03.036 · Cited by 275
Anisotropic properties of human tibial cortical bone as measured by nanoindentation
Fan, Z., Swadener, J. G., Rho, J. Y., Roy, M. E., & Pharr, G. M. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00186-3 · Cited by 254
The indentation modulus of elastically anisotropic materials for indenters of arbitrary shape
Vlassak, J. J., Ciavarella, M., Barber, J. R., & Wang, X. (2003) · Journal of the Mechanics and Physics of Solids · doi:10.1016/s0022-5096(03)00066-8 · Cited by 217
“Vlassak and Nix (1993) deÿned the indentation modulus, M , of a general anisotropic material through the following equation: S = dF dU = 2 √ M √ A; (1) where F is the applied load, U the approach of the two bodies, and A the projected contact area.”
BackgroundMethodSelf-citationElastic Anisotropy of Human Cortical Bone Secondary Osteons Measured by Nanoindentation
Franzoso, G., & Zysset, P. K. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3005162 · Cited by 89
Metadata
- Authors
- Vlassak, J. J., & Nix, W. D.
- Venue
- Philosophical Magazine A
- Publisher
- Informa UK Limited
- Published
- 1993-05
- Volume
- 67
- Issue
- 5
- Pages
- 1045-1056
- ISSN
- 0141-8610 (ISSN-L)
- 1460-6992
- OpenAlex
- W2076997794
- Cited by
- 297
- References
- 5
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.