Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,051

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Quantification of Bone Microarchitecture with the Structure Model Index

HILDEBRAND, TOR, RÜEGSEGGER, PETER·1997·Computer Methods in Biomechanics and Biomedical Engineering

Abstract

The deterioration of cancellous bone structure due to aging and disease is characterized by a conversion from plate elements to rod elements. Consequently the terms "rod-like" and "plate-like" are frequently used for a subjective classification of cancellous bone. In this work a new morphometric parameter called Structure Model Index (SMI) is introduced, which makes it possible to quantify the characteristic form of a three-dimensionally described structure in terms of the amount of plates and rod composing the structure. The SMI is calculated by means of three-dimensional image analysis based on a differential analysis of the triangulated bone surface. For an ideal plate and rod structure the SMI value is 0 and 3, respectively, independent of the physical dimensions. For a structure with both plates and rods of equal thickness the value lies between 0 and 3, depending on the volume ratio of rods and plates. The SMI parameter is evaluated by examining bone biopsies from different skeletal sites. The bone samples were measured three-dimensionally with a micro-CT system. Samples with the same volume density but varying trabecular architecture can uniquely be characterized with the SMI. Furthermore the SMI values were found to correspond well with the perceived structure type.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/01495739708936692

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 1,051

Metadata

Authors
HILDEBRAND, T., & RÜEGSEGGER, P.
Venue
Computer Methods in Biomechanics and Biomedical Engineering
Published
1997-01
Volume
1
Issue
1
Pages
15-23
ISSN
  • 1025-5842 (ISSN-L)
  • 1476-8259
OpenAlex
W2256257390
Cited by
1,051
References
2
FWCI
3.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.