Inhalation Exposure Systems: Design, Methods and Operation
The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
The respiratory system, the major route for entry of oxygen into the body, provides entry for external compounds, including pharmaceutic and toxic materials. These compounds (that might be inhaled under environmental, occupational, medical, or other situations) can be administered under controlled conditions during laboratory inhalation studies. Inhalation study results may be controlled or adversely affected by variability in four key factors: animal environment; exposure atmosphere; inhaled dose; and individual animal biological response. Three of these four factors can be managed through engineering processes. Variability in the animal environment is reduced by engineering control of temperature, humidity, oxygen content, waste gas content, and noise in the exposure facility. Exposure atmospheres are monitored and adjusted to assure a consistent and known exposure for each animal dose group. The inhaled dose, affected by changes in respiration physiology, may be controlled by exposure-specific monitoring of respiration. Selection of techniques and methods for the three factors affected by engineering allows the toxicologic pathologist to study the reproducibility of the fourth factor, the biological response of the animal.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For diseases such as lung cancer or airway remodelling driven by chronic inflammation, most studies have been done with mice or rats either in whole-body chambers (Heinrich et al., 1995) or in nose-only exposure towers (Pauluhn, 1994, 2008; Wong, 2007).”
From Toxicity of lunar dust (2012) · cites this paper as Wong, 2007
Citations
Cites
Guide for the Care and Use of Laboratory Animals: Eighth Edition
(2011) · doi:10.17226/12910 · Cited by 16,199
Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine Particles
Oberdörster, G., Oberdörster, E., & Oberdörster, J. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7339 · Cited by 7,891 · cited 1×
“…particles, in part due to recent studies linking environmental particulate matter (PM) pollution to increased morbidity and mortality (Schwartz, 1994; Oberdorster et al., 1995) and due to recent developments in nanotechnology and nano-sized materials (Colvin, 2003; Oberdorster et al., 2005).”
BackgroundThe 1996 Guide for the Care and Use of Laboratory Animals
Clark, J. D., Gebhart, G. F., Gonder, J. C., Keeling, M. E., & Kohn, D. F. (1997) · ILAR Journal · doi:10.1093/ilar.38.1.41 · Cited by 4,417
The potential environmental impact of engineered nanomaterials
Colvin, V. L. (2003) · Nature Biotechnology · doi:10.1038/nbt875 · Cited by 2,158 · cited 3×
“, 1995) and due to recent developments in nanotechnology and nano-sized materials (Colvin, 2003; Oberdorster et al., 2005).”
BackgroundAir Pollution and Daily Mortality: A Review and Meta Analysis
Schwartz, J. (1994) · Environmental Research · doi:10.1006/enrs.1994.1005 · Cited by 884 · cited 1×
“…or nanometer particles, in part due to recent studies linking environmental particulate matter (PM) pollution to increased morbidity and mortality (Schwartz, 1994; Oberdorster et al., 1995) and due to recent developments in nanotechnology and nano-sized materials (Colvin, 2003; Oberdorster et…”
BackgroundAssociation of Particulate Air Pollution and Acute Mortality: Involvement of Ultrafine Particles?
Oberdörster, G., Celein, R. M., Ferin, J., & Weiss, B. (1995) · Inhalation Toxicology · doi:10.3109/08958379509014275 · Cited by 626 · cited 1×
“…particles, in part due to recent studies linking environmental particulate matter (PM) pollution to increased morbidity and mortality (Schwartz, 1994; Oberdorster et al., 1995) and due to recent developments in nanotechnology and nano-sized materials (Colvin, 2003; Oberdorster et al., 2005).”
BackgroundMEASUREMENT OF THE RESPIRATORY VOLUMES OF LABORATORY ANIMALS
Guyton, A. C. (1947) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1947.150.1.70 · Cited by 593 · cited 1×
“Also, minute ventilation can be determined from: Vm = f × VT Average values for the minute ventilation ,Vm can be estimated from body mass using empirical allometric scaling formulae (Guyton, 1947; Bide et al., 2000).”
MethodDriscoll, K. E. (2000) · Toxicological Sciences · doi:10.1093/toxsci/55.1.24 · Cited by 578 · cited 1×
“However, the clearance of the material showed a different pattern between intratracheal instillation or oropharyngeal aspiration, and nose-only inhalation (Foster et al., 2001).”
BackgroundAnimal Inhalation Exposure Chambers
Hinners, R. G., Burkart, J. K., & Punte, C. L. (1968) · Archives of Environmental Health: An International Journal · doi:10.1080/00039896.1968.10665043 · Cited by 230
Efficacy of a Technique for Exposing the Mouse Lung to Particles Aspirated from the Pharynx
Rao, G. V. S., Tinkle, S., Weissman, D., Antonini, J., Kashon, M., Salmen, R., Battelli, L., Willard, P., Hubbs, A., & Hoover, M. (2003) · Journal of Toxicology and Environmental Health, Part A · doi:10.1080/15287390306417 · Cited by 216
Bide, R. W., Armour, S. J., & Yee, E. (2000) · Journal of Applied Toxicology · doi:10.1002/1099-1263(200007/08)20:4<273::aid-jat657>3.0.co;2-x · Cited by 171 · cited 2×
“Also, minute ventilation can be determined from: Vm = f × VT Average values for the minute ventilation ,Vm can be estimated from body mass using empirical allometric scaling formulae (Guyton, 1947; Bide et al., 2000).”
MethodChang, J. C. F., Gross, E. A., Swenberg, J. A., & Barrow, C. S. (1983) · Toxicology and Applied Pharmacology · doi:10.1016/0041-008x(83)90001-7 · Cited by 167 · cited 1×
“Formaldehyde concentration is controlled by varying oven temperature, container size, and chamber air flow (Chang et al., 1983).”
BackgroundThe Flow-Past Chamber: An Improved Nose-Only Exposure System for Rodents
CANNON, W. C., BLANTON, E. F., & McDONALD, K. E. (1983) · American Industrial Hygiene Association Journal · doi:10.1080/15298668391405959 · Cited by 162 · cited 2×
“If the airflow is too low, downstream test subjects may get a lower dose, or the dose to each test subject may be more variable (Cannon et al., 1983).”
BackgroundHartings, J. M., & Roy, C. J. (2003) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2003.07.001 · Cited by 153 · cited 1×
“This type of feed back system has been used to expose primates to a predetermined bioaerosol dose (Hartings and Roy, 2004).”
MethodAn improved apparatus for acute inhalation exposure of rodents to radioactive aerosols
Raabe, O. G., Bennick, J. E., Light, M. E., HOBBS, C. H., Thomas, R. L., & TILLERY, M. I. (1973) · Toxicology and Applied Pharmacology · doi:10.1016/0041-008x(73)90261-5 · Cited by 150
Methodology for the measurement of mucociliary function in the mouse by scintigraphy
Foster, W. M., Walters, D. M., Longphre, M., Macri, K., & Miller, L. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.3.1111 · Cited by 140 · cited 1×
“However, the clearance of the material showed a different pattern between intratracheal instillation or oropharyngeal aspiration, and nose-only inhalation (Foster et al., 2001).”
BackgroundCassee, F. R., Muijser, H., Duistermaat, E., Freijer, J. I., Geerse, K. B., Marijnissen, J. C. M., & Arts, J. H. E. (2002) · Archives of Toxicology · doi:10.1007/s00204-002-0344-8 · Cited by 137 · cited 2×
“For example, in an inhalation study, young male Wistar rats were exposed in a nose-only system (Cassee et al, 2002).”
BackgroundMethodEffect of Impaction, Bounce and Reaerosolization on the Collection Efficiency of Impingers
Grinshpun, S. A., Willeke, K., Ulevicius, V., Juozaitis, A., Terzieva, S., Donnelly, J., Stelma, G. N., & Brenner, K. P. (1997) · Aerosol Science and Technology · doi:10.1080/02786829708965434 · Cited by 128 · cited 1×
“Also, collected particles in the liquid can be reaerosolized from bubbles bursting at the liquid surface (Grinshpun et al., 1997).”
BackgroundPulmonary function assessment by whole-body plethysmography in restrained versus unrestrained mice
DeLorme, M. P., & Moss, O. R. (2002) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(02)00191-0 · Cited by 120 · cited 1×
“Both of these types of chambers can be used to measure the breathing frequency and tidal volume of an individual animal leading to a determination of the volume of air inhaled (DeLorme and Moss, 2002).”
BackgroundGeneration of Ultrafine Particles by Spark Discharging
Roth, C., FERRON, G. A., Karg, E. W., Lentner, B., Schumann, G., Takenaka, S., & Heyder, J. (2004) · Aerosol Science and Technology · doi:10.1080/02786820490247632 · Cited by 108
Handbook of in vivo toxicity testing
Arnold, D. L., Grice, H. C., & Krewski, D. R. (1990) · Academic Press eBooks · Cited by 97
Constant flow gassing chambers; principles influencing design and operation.
Sd, S. (1946) · PubMed · Cited by 96
Improved methodology for generating controlled test atmospheres
Miller, R. R., LETTS, R. L., POTTS, W. J., & McKENNA, M. J. (1980) · American Industrial Hygiene Association Journal · doi:10.1080/15298668091425743 · Cited by 89
ANALYSIS OF RESPIRATORY PATTERNS IN LABORATORY ANIMALS
Guyton, A. C. (1947) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1947.150.1.78 · Cited by 87 · cited 2×
“Also, minute ventilation can be determined from: Vm = f × VT Average values for the minute ventilation ,Vm can be estimated from body mass using empirical allometric scaling formulae (Guyton, 1947; Bide et al., 2000).”
MethodDesign and performance of a single-pass bubbling bioaerosol generator
Mainelis, G., Berry, D., An, H. R., Yao, M., DeVoe, K., Fennell, D. E., & Jaeger, R. J. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.02.043 · Cited by 85 · cited 1×
“An aerosol disperser was developed to produce an aerosol of microorganisms from droplets formed from the bursting of bubbles (Ulevicius, 1997; Mainelis et al., 2005).”
Techniques for Dispersion of Microorganisms into Air
Reponen, T., Willeke, K., Ulevicius, V., Grinshpun, S. A., & Donnelly, J. (1997) · Aerosol Science and Technology · doi:10.1080/02786829708965481 · Cited by 81 · cited 1×
“Other methods have used the combustion or high-temperature reactions of precursor compounds to produce submicron particles of various metal oxides (Kanapilly et al., 1970; Kanapilly et al., 1978; Crisp et al, 1981; Roth et al., 2004).”
MethodGas Mixtures: Preparation and Control
NELSON, G. O. (1992) · Cited by 78
Validation of an improved nose-only exposure system for rodents
Pauluhn, J. (1994) · Journal of Applied Toxicology · doi:10.1002/jat.2550140111 · Cited by 65
Method and test system for evaluation of bioaerosol samplers
Thompson, M. W., Donnelly, J., Grinshpun, S. A., Juozaitis, A., & Willeke, K. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90226-7 · Cited by 64
Development of a low cutpoint slit virtual impactor for sampling ambient fine particles
Sioutas, C., Koutrakis, P., & Burton, R. M. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90128-7 · Cited by 60
Aerosolization of Particles from a Bubbling Liquid: Characteristics and Generator Development
Ulevičius, V., Willeke, K., Grinshpun, S. A., Donnelly, J., Lin, X., & Mainelis, G. (1997) · Aerosol Science and Technology · doi:10.1080/02786829708965423 · Cited by 53
Lin, W., & Li, C.-S. (1998) · Aerosol Science and Technology · doi:10.1080/02786829808965542 · Cited by 44 · cited 1×
“The impingement and impaction process may also stress microorganisms and cause loss of viability (Lin and Li, 1998).”
BackgroundIn vivo deposition of ultrafine aerosols in the nasal airway of the rat
Gerde, P., Cheng, Y. S., & Medinsky, M. A. (1991) · Fundamental and Applied Toxicology · doi:10.1016/0272-0590(91)90117-m · Cited by 42 · cited 1×
“The other cannula, inserted toward the larynx, is used to draw an atmosphere through the nasal passages (Gerde et al., 1991; Kelly et al., 2001; Schroeter et al., 2006).”
BackgroundSchroeter, J. D., Kimbell, J. S., Bonner, A. M., Roberts, K. C., Andersen, M. E., & Dorman, D. C. (2005) · Toxicological Sciences · doi:10.1093/toxsci/kfj072 · Cited by 42 · cited 1×
“…or nanometer particles, in part due to recent studies linking environmental particulate matter (PM) pollution to increased morbidity and mortality (Schwartz, 1994; Oberdorster et al., 1995) and due to recent developments in nanotechnology and nano-sized materials (Colvin, 2003; Oberdorster et…”
BackgroundA new method for the generation of aerosols of insoluble particles
Kanapilly, G. M., Raabe, O. G., & Newton, G. J. (1970) · Journal of Aerosol Science · doi:10.1016/0021-8502(70)90005-4 · Cited by 40 · cited 1×
“Other methods have used the combustion or high-temperature reactions of precursor compounds to produce submicron particles of various metal oxides (Kanapilly et al., 1970; Kanapilly et al., 1978; Crisp et al, 1981; Roth et al., 2004).”
MethodEffects of pollutant atmospheres on surface receptors of pulmonary macrophages
Prasad, S. B., Rao, V. S., Mannix, R. C., & Phalen, R. F. (1988) · Journal of Toxicology and Environmental Health · doi:10.1080/15287398809531169 · Cited by 34
Air pollution—Physiological effects
(1984) · Environmental Pollution Series A Ecological and Biological · doi:10.1016/0143-1471(84)90067-9 · Cited by 33
Hepatocyte cell proliferation in mice after inhalation exposure to unleaded gasoline vapor
Tilbury, L. F., Butterworth, B. E., Moss, O. R., & Goldsworthy, T. L. (1993) · Journal of Toxicology and Environmental Health · doi:10.1080/15287399309531719 · Cited by 33 · cited 1×
“The J-tube or the carrier gas can be heated to aid evaporation (Miller et al., 1980; Tilbury et al., 1993; Wong, 1995).”
BackgroundInertial Separation of Ultrafine Particles Using a Condensational Growth/Virtual Impaction System
Sioutas, C., & Koutrakis, P. (1996) · Aerosol Science and Technology · doi:10.1080/02786829608965407 · Cited by 33 · cited 1×
“The large particles can also be separated out of an aerosol stream by using a cyclone or virtual impactor (Sioutas et al., 1994; Sioutas and Koutrakis, 1996).”
MethodMethods in Inhalation Toxicology
ROTHENBERG, S. J. (1997) · International Journal of Toxicology · doi:10.1177/109158189701600614 · Cited by 31
A Venturi Disperser as a Dry Powder Generator for Inhalation Studies
Cheng, Y. S., Barr, E. B., & Yeh, H. C. (1989) · Inhalation Toxicology · doi:10.3109/08958378909145239 · Cited by 28 · cited 2×
“An exposure system should be checked for uniformity of distribution prior to the start of a study (Moss, 1981; Cheng et al., 1989; Wong, 1999).”
BackgroundKanapilly, G. M., Tu, K. W., Larsen, T. B., Fogel, G. R., & Luna, R. J. (1978) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(78)90106-6 · Cited by 25 · cited 1×
“Other methods have used the combustion or high-temperature reactions of precursor compounds to produce submicron particles of various metal oxides (Kanapilly et al., 1970; Kanapilly et al., 1978; Crisp et al, 1981; Roth et al., 2004).”
Method(1992) · Fundamental and Applied Toxicology · doi:10.1016/0272-0590(92)90130-a · Cited by 25
Evaluation of the condensation aerosol generator for producing monodispersed aerosols
Tomaides, M., Liu, B. Y. H., & WHITBY, K. T. (1971) · Journal of Aerosol Science · doi:10.1016/0021-8502(71)90006-1 · Cited by 23 · cited 1×
“The vapor condensation method has been used to produce a relatively large number concentration of monodisperse particles (Tomaides et al., 1971).”
MethodBernstein, D. M., Mast, R., Anderson, R., Hesterberg, T. W., Musselman, R., Kamstrup, O., & Hadley, J. (1994) · Environmental Health Perspectives · doi:10.1289/ehp.94102s515 · Cited by 21 · cited 1×
“This method has also been used to generate fibrous particulates (Bernstein et al., 1994).”
MethodKelly, J. T. (2001) · Toxicological Sciences · doi:10.1093/toxsci/64.2.253 · Cited by 21 · cited 1×
“The other cannula, inserted toward the larynx, is used to draw an atmosphere through the nasal passages (Gerde et al., 1991; Kelly et al., 2001; Schroeter et al., 2006).”
BackgroundImprovement of Aerosol Distribution in Whole-Body Inhalation Exposure Chambers
Cheng, Y., Barr, E. B., Carpenter, R. L., Benson, J. M., & HOBBS, C. H. (1989) · Inhalation Toxicology · doi:10.3109/08958378909145663 · Cited by 20 · cited 2×
“An exposure system should be checked for uniformity of distribution prior to the start of a study (Moss, 1981; Cheng et al., 1989; Wong, 1999).”
BackgroundCheng, Y., & Moss, O. R. (1995) · CRC Press eBooks · doi:10.1201/b14404-5 · Cited by 19
Annual Report of the Inhalation Toxicology Research Institute 1991-1992
Mauderly, J. L., Finch, G. L., Nikula, K. J., & Bradley, P. L. (1992) · Defense Technical Information Center (DTIC) · Cited by 17
Vitarella, D. (1998) · Inhalation Toxicology · doi:10.1080/089583798197303 · Cited by 17 · cited 1×
“Small, single animal holders, developed for individual exposures (Leavens et al., 1996), have also been used to house a dam and pups for reproductive and developmental studies to inhaled materials (Dorman et al., 1996, Vitarella et al., 1998).”
BackgroundMoss, O. R., James, R. A., & Asgharian, B. (2006) · Inhalation Toxicology · doi:10.1080/08958370500282555 · Cited by 15
Dosimetry of Particles in Laboratory Animals and Humans
Miller, F. J. (1999) · Cited by 15
Evaluation of a real-time aerosol monitor (RAM-S) for inhalation studies
Cheng, Y. S. (1988) · Fundamental and Applied Toxicology · doi:10.1016/0272-0590(88)90317-x · Cited by 13
The generation and the measurement of dry aerosols in large-scale inhalation experiments
Koch, W., Lödding, H., Oenning, G., & Muhle, H. (1986) · Journal of Aerosol Science · doi:10.1016/0021-8502(86)90143-6 · Cited by 12 · cited 1×
“In another disperser, the dispensed powder falls into high-velocity air jets blowing horizontally, that break up the powder (Koch et al., 1986).”
BackgroundSajewicz, W., & Długosz, A. (2000) · Journal of Applied Toxicology · doi:10.1002/1099-1263(200007/08)20:4<335::aid-jat698>3.0.co;2-l · Cited by 11
Development of a Mouse Whole-Body Exposure System from a Directed-Flow, Rat Nose-Only System
Dorman, D. C., Wong, B. A., Struve, M. F., James, R. A., LaPerle, K., Marshall, M. W., & Bolon, B. N. (1996) · Inhalation Toxicology · doi:10.3109/08958379609005430 · Cited by 11 · cited 1×
“Small, single animal holders, developed for individual exposures (Leavens et al., 1996), have also been used to house a dam and pups for reproductive and developmental studies to inhaled materials (Dorman et al., 1996, Vitarella et al., 1998).”
BackgroundSelf-citationGeneration and Characterization of Test Atmospheres
Moss, O. R., & Cheng, V.-S. (1995) · CRC Press eBooks · doi:10.1201/b14404-7 · Cited by 11 · cited 1×
“Other bulk pow- der feeders use a conveyer belt system (Moss and Cheng, 1995).”
BackgroundApplication of a Building Management System to Automate a 90-Day Chloroform Inhalation Study
Wong, B. A., & Moss, O. R. (1996) · Toxicology Methods · doi:10.3109/15376519609068453 · Cited by 10 · cited 3×
“Infrared spectrophotometry and gas chromatography have the potential to provide atmosphere concentration in near real time, and have been used to provide data for automated feedback loops for controlling chamber atmosphere concentration (Wong and Moss, 1996; Wong, 2003).”
BackgroundMethodInfluentialSelf-citationDynamic Inhalation System for Individual Whole-Body Exposure of Mice to Volatile Organic Chemicals
Leavens, T. L., Moss, O. R., & Bond, J. A. (1996) · Inhalation Toxicology · doi:10.3109/08958379609005446 · Cited by 5 · cited 1×
“Small, single animal holders, developed for individual exposures (Leavens et al., 1996), have also been used to house a dam and pups for reproductive and developmental studies to inhaled materials (Dorman et al., 1996, Vitarella et al., 1998).”
BackgroundWong, B. A. (2003) · Inhalation Toxicology · doi:10.1080/08958370390217819 · Cited by 4
Self-citationAn improved generator for the production of metal oxide fume
Crisp, S., HARDCASTLE, W. A., NUNAN, J. M., & Smith, A. F. (1981) · American Industrial Hygiene Association Journal · doi:10.1080/15298668191420323 · Cited by 2 · cited 1×
“Other methods have used the combustion or high-temperature reactions of precursor compounds to produce submicron particles of various metal oxides (Kanapilly et al., 1970; Kanapilly et al., 1978; Crisp et al, 1981; Roth et al., 2004).”
Method
Research works printed but not linked: 14
- Baron PA, 2001, Aerosol Measurement, 495
- Chen BT, 2001, Aerosol Measurement, 627
- Gebhart J, 2001, Aerosol Measurement, 419
- Hinds WC, 1999, Aerosol Technology
- LeeKWMukundRBaronPAWillekeKAerosol Measurement20012New YorkJohn Wiley & Sons197228
- Marple VA, 2001, Aerosol Measurement, 229
- Miller FJ, 1999, Toxicology of the Lung, 513
- Moss OR, 1981, Inhalation Toxicology and Technology, 19
- Moss OR, 2001, Aerosol Measurement, 1053
- Pott F, 1993, Fiber Toxicology, 395
- Reponen T, 2001, Aerosol Measurement, 751
- Silver SD, 1946, J Lab Clin Med, 31, 1153
- Smith DM, 1981, Inhalation Toxicology and Technology, 89
- Wong BA, 1999, Toxicology of the Lung, 1
Cited by
Inhalation Exposure to Carbon Nanotubes (CNT) and Carbon Nanofibers (CNF): Methodology and Dosimetry
Oberdörster, G., Castranova, V., Asgharian, B., & Sayre, P. (2015) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937404.2015.1051611 · Cited by 150
“Generators for droplet (liquid) and dry dust (powder) aerosols were reported (Phalen 2009; Wong 2007).”
BackgroundNahar, K., Gupta, N., Gauvin, R., Absar, S., Patel, B., Gupta, V., Khademhosseini, A., & Ahsan, F. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.06.004 · Cited by 168
“However, these two exposure chambers have some drawbacks: animals cannot get food and water during exposure, the system may generate heat, and animals may get suffocated in the chamber and require intensive labor (Wong, 2007).”
InfluentialCosta-Gouveia, J., Pancani, E., Jouny, S., Machelart, A., Delorme, V., Salzano, G., Iantomasi, R., Piveteau, C., Queval, C. J., Song, O., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-05453-3 · Cited by 107
In vitro Alternatives to Acute Inhalation Toxicity Studies in Animal Models—A Perspective
Movia, D., Bruni-Favier, S., & Prina‐Mello, A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00549 · Cited by 109
“However, our manuscript does not address issues associated with exposure technology, test compound characterization and dosimetry, as these have already been identified and described in detail elsewhere (Dorato and Wolff, 1991; Oberdorster, 1996; Pauluhn, 2003, 2005; Wong, 2007; Phalen and Mendez, 2009; Clippinger et…”
BackgroundLinnarsson, D., Carpenter, J., Fubini, B., Gerde, P., Karlsson, L. L., Loftus, D. J., Prisk, G. K., Staufer, U., Tranfield, E. M., & van Westrenen, W. (2012) · Planetary and Space Science · doi:10.1016/j.pss.2012.05.023 · Cited by 95
“For diseases such as lung 600 cancer or airway remodelling driven by chronic inflammation, most studies have been 601 done with mice or rats either in whole-body chambers (Heinrich et al., 1995) or in 602 nose-only exposure towers (Pauluhn, 1994, 2008; Wong, 2007).”
Background
Metadata
- Authors
- Wong, B. A.
- Affiliations
- CIIT Centers for Health Research, Research Triangle Park, NC 27709, USA
- Corresponding author
- Wong, Brian A.
- Venue
- Toxicologic Pathology
- Publisher
- SAGE Publications
- Published
- 2007-01
- Volume
- 35
- Issue
- 1
- Pages
- 3-14
- ISSN
- 0192-6233 (ISSN-L)
- 1533-1601
- OpenAlex
- W2085530326
- Cited by
- 137
- References
- 60
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 7 · 2023: 8 · 2022: 4 · 2021: 16 · 2020: 8 · 2019: 11 · 2018: 10 · 2017: 10 · 2016: 8 · 2015: 9 · 2014: 8 · 2013: 4 · 2012: 8
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Toxicologic Pathology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
- Life Sciences › Immunology and Microbiology › Immunology › Immunotoxicology and immune responses
- Keywords
- inhalation toxicity testing, respiratory monitoring, respiratory physiology
- MeSH terms
- Aerosols, Air Pollutants, Animals, Xenobiotics, Guidelines as Topic, Toxicity Tests, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.