The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Prediction of energy expenditure from heart rate monitoring during submaximal exercise
Abstract
The aims of this study were to quantify the effects of factors such as mode of exercise, body composition and training on the relationship between heart rate and physical activity energy expenditure (measured in kJ x min(-1)) and to develop prediction equations for energy expenditure from heart rate. Regularly exercising individuals (n = 115; age 18-45 years, body mass 47-120 kg) underwent a test for maximal oxygen uptake (VO2max test), using incremental protocols on either a cycle ergometer or treadmill; VO2max ranged from 27 to 81 ml x kg(-1) x min(-1). The participants then completed three steady-state exercise stages on either the treadmill (10 min) or the cycle ergometer (15 min) at 35%, 62% and 80% of VO2max, corresponding to 57%, 77% and 90% of maximal heart rate. Heart rate and respiratory exchange ratio data were collected during each stage. A mixed-model analysis identified gender, heart rate, weight, V2max and age as factors that best predicted the relationship between heart rate and energy expenditure. The model (with the highest likelihood ratio) was used to estimate energy expenditure. The correlation coefficient (r) between the measured and estimated energy expenditure was 0.913. The model therefore accounted for 83.3% (R2) of the variance in energy expenditure in this sample. Because a measure of fitness, such as VO2max, is not always available, a model without VO2max included was also fitted. The correlation coefficient between the measured energy expenditure and estimates from the mixed model without VO2max was 0.857. It follows that the model without a fitness measure accounted for 73.4% of the variance in energy expenditure in this sample. Based on these results, we conclude that it is possible to estimate physical activity energy expenditure from heart rate in a group of individuals with a great deal of accuracy, after adjusting for age, gender, body mass and fitness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Durnin, J. V. G. A., & Womersley, J. (1974) · British Journal of Nutrition · doi:10.1079/bjn19740060 · Cited by 6,343
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Peak power output predicts maximal oxygen uptake and performance time in trained cyclists
Hawley, J. A., & Noakes, T. D. (1992) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf01466278 · Cited by 422
Self-citationEnergy expenditure from minute-by-minute heart-rate recording: comparison with indirect calorimetry
Spurr, G., Prentice, A., Murgatroyd, P., Goldberg, G., Reina, J., & Christman, N. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.3.552 · Cited by 414
Peak treadmill running velocity during the V O2max test predicts running performance
Noakes, T. D., Myburgh, K. H., & Schall, R. (1990) · Journal of Sports Sciences · doi:10.1080/02640419008732129 · Cited by 361
Self-citationCeesay, S. M., Prentice, A. M., Day, K. C., Murgatroyd, P. R., Goldberg, G. R., Scott, W., & Spurr, G. B. (1989) · British Journal of Nutrition · doi:10.1079/bjn19890107 · Cited by 318
Evaluation of heart rate as a method for assessing moderate intensity physical activity
STRATH, S. J., SWARTZ, A. M., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00005 · Cited by 301
Effect of exercise training on total daily physical activity in elderly humans
Meijer, E. P., Westerterp, K. R., & Verstappen, F. T. J. (1999) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/s004210050552 · Cited by 181
SURROGATE MEASURES OF PHYSICAL ACTIVITY AND PHYSICAL FITNESS
Blair, S. N., Kannel, W. B., Kohl, H. W., Goodyear, N. N., & Wilson, P. W. F. (1989) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a115236 · Cited by 143
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Warren, J. M., Ekelund, U., Besson, H., Mezzani, A., Geladas, N., & Vanhees, L. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832ed875 · Cited by 587
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336
Brage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking.
(2016) · PubMed Central · Cited by 150
Metadata
- Authors
- Keytel, L., Goedecke, J., Noakes, T., Hiiloskorpi, H., Laukkanen, R., van der Merwe, L., & Lambert, E.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2005-03
- Volume
- 23
- Issue
- 3
- Pages
- 289-297
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2138348947
- Cited by
- 331
- References
- 17
- FWCI
- 7.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prediction of energy expenditure from heart rate monitoring during submaximal exercise. https://app.cochat.ai/papers/10.1080/02640410470001730089
- The paper
- Keytel, L., Goedecke, J., Noakes, T., Hiiloskorpi, H., Laukkanen, R., van der Merwe, L., & Lambert, E. (2005). Prediction of energy expenditure from heart rate monitoring during submaximal exercise. Journal of Sports Sciences. https://doi.org/10.1080/02640410470001730089
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.