Sprint starts and the minimum auditory reaction time
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The simple auditory reaction time is one of the fastest reaction times and is thought to be rarely less than 100 ms. The current false start criterion in a sprint used by the International Association of Athletics Federations is based on this assumed auditory reaction time of 100 ms. However, there is evidence, both anecdotal and from reflex research, that simple auditory reaction times of less than 100 ms can be achieved. Reaction time in nine athletes performing sprint starts in four conditions was measured using starting blocks instrumented with piezoelectric force transducers in each footplate that were synchronized with the starting signal. Only three conditions were used to calculate reaction times. The pre-motor and pseudo-motor time for two athletes were also measured across 13 muscles using surface electromyography (EMG) synchronized with the rest of the system. Five of the athletes had mean reaction times of less than 100 ms in at least one condition and 20% of all starts in the first two conditions had a reaction time of less than 100 ms. The results demonstrate that the neuromuscular-physiological component of simple auditory reaction times can be under 85 ms and that EMG latencies can be under 60 ms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aviation, Space, and Environmental Medicine
(2011) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2010.11.006 · Cited by 1,188
Journal of Human Movement Studies
D., C. P. (1975) · The American Journal of Psychology · doi:10.2307/1421916 · Cited by 781
(2006) · Springer eBooks · doi:10.1007/0-387-28287-4 · Cited by 717
Neurophysiological basis of movement
(1998) · Choice Reviews Online · doi:10.5860/choice.36-1033 · Cited by 373
Electromechanical delay: An experimental artifact
Corcos, D. M., Gottlieb, G. L., Latash, M. L., Almeida, G. L., & Agarwal, G. C. (1992) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(92)90017-d · Cited by 255 · cited 1×
“Keywords: Neurophysiology, reflex, athletics”
Anticipatory postural adjustments during self-paced and reaction-time movements
de Wolf, S., Slijper, H. P., & Latash, M. L. (1998) · Experimental Brain Research · doi:10.1007/s002210050431 · Cited by 162 · cited 1×
“De Wolf, Slijper and Latash (1998) observed an interaction between reaction-time movements and the timing and magnitude of anticipatory postural adjustment profiles.”
BackgroundElectromechanical response times and muscle elasticity in men and women
Winter, E. M., & Brookes, F. B. C. (1991) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00235181 · Cited by 162 · cited 2×
“Keywords: Neurophysiology, reflex, athletics”
BackgroundVoluntary stimulus‐sensitive jerks and jumps mimicking myoclonus or pathological startle syndromes
Thompson, P. D., Colebatch, J. G., Brown, P., Rothwell, J. C., Day, B. L., Obeso, J. A., & MARSDEN, C. D. (1992) · Movement Disorders · doi:10.1002/mds.870070312 · Cited by 157 · cited 3×
“In the research literature, this 100 ms value is claimed to be the minimum physiological simple auditory reaction time possible, as determined by a number of empirical studies (e.g. Mero & Komi, 1990; Thompson et al., 1992).”
BackgroundMethodInfluence of tendon slack on electromechanical delay in the human medial gastrocnemius in vivo
Muraoka, T., Muramatsu, T., Fukunaga, T., & Kanehisa, H. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01015.2002 · Cited by 144 · cited 1×
“Keywords: Neurophysiology, reflex, athletics”
Ethanol and Sleep Loss: A “Dose” Comparison of Impairing Effects
Roehrs, T., Burduvali, E., Bonahoom, A., Drake, C., & Roth, T. (2003) · Sleep · doi:10.1093/sleep/26.8.981 · Cited by 101 · cited 1×
“, 2004) and impairment detection (Roehrs et al., 2003) through to environmental safety (Philipova, 1998, Haas and Edworthy, 2003) and sports (Guissard and Duchateau, 1990).”
Background
Cited by
Jain, A., Bansal, R., Kumar, A., & Singh, K. (2015) · International Journal of Applied and Basic Medical Research · doi:10.4103/2229-516x.157168 · Cited by 421
Sprint Running Performance Monitoring: Methodological and Practical Considerations
Haugen, T., & Buchheit, M. (2016) · Sports Medicine · doi:10.1007/s40279-015-0446-0 · Cited by 385
5G: Personal mobile internet beyond what cellular did to telephony
Fettweis, G., & Alamouti, S. (2014) · IEEE Communications Magazine · doi:10.1109/mcom.2014.6736754 · Cited by 306
Comparison between Auditory and Visual Simple Reaction Times
Shelton, J., & Kumar, G. P. (2010) · Neuroscience and Medicine · doi:10.4236/nm.2010.11004 · Cited by 292
Neuromuscular Performance of Explosive Power Athletes versus Untrained Individuals
TILLIN, N. A., JIMENEZ-REYES, P., PAIN, M. T. G., & FOLLAND, J. P. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181be9c7e · Cited by 284
“Additionally, manual identification of force/EMG onsets has been found more accurate, and detects onsets up to 60 ms earlier than automatic threshold methods (2, 33, 35).”
Self-citationBuckthorpe, M. W., Hannah, R., Pain, T. G., & Folland, J. P. (2012) · Muscle & Nerve · doi:10.1002/mus.23322 · Cited by 168
Tillin, N. A., & Folland, J. P. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-013-2781-x · Cited by 140
Short‐term training for explosive strength causes neural and mechanical adaptations
Tillin, N. A., Pain, M. T. G., & Folland, J. P. (2012) · Experimental Physiology · doi:10.1113/expphysiol.2011.063040 · Cited by 120
“Force and EMG onsets during the explosive voluntary and evoked contractions were identified manually, which is considered the ‘gold standard’ method for detecting signal onsets (Allison, 2003; Moretti et al. 2003; Pain & Hibbs, 2007; Pulkovski et al. 2008).”
MethodSelf-citationTillin, N. A., Pain, M. T. G., & Folland, J. P. (2011) · Muscle & Nerve · doi:10.1002/mus.21885 · Cited by 112
Self-citationStartle responses in functional jerky movement disorders are increased but have a normal pattern
Dreissen, Y. E. M., Boeree, T., Koelman, J. H. T. M., & Tijssen, M. A. J. (2017) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2017.04.001 · Cited by 20
Metadata
- Authors
- Pain, M. T. G., & Hibbs, A.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2007-01
- Volume
- 25
- Issue
- 1
- Pages
- 79-86
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2127110596
- Cited by
- 160
- References
- 14
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.