Validity of inertial sensor based 3D joint kinematics of static and dynamic sport and physiotherapy specific movements
Open accessAbstract
3D joint kinematics can provide important information about the quality of movements. Optical motion capture systems (OMC) are considered the gold standard in motion analysis. However, in recent years, inertial measurement units (IMU) have become a promising alternative. The aim of this study was to validate IMU-based 3D joint kinematics of the lower extremities during different movements. Twenty-eight healthy subjects participated in this study. They performed bilateral squats (SQ), single-leg squats (SLS) and countermovement jumps (CMJ). The IMU kinematics was calculated using a recently-described sensor-fusion algorithm. A marker based OMC system served as a reference. Only the technical error based on algorithm performance was considered, incorporating OMC data for the calibration, initialization, and a biomechanical model. To evaluate the validity of IMU-based 3D joint kinematics, root mean squared error (RMSE), range of motion error (ROME), Bland-Altman (BA) analysis as well as the coefficient of multiple correlation (CMC) were calculated. The evaluation was twofold. First, the IMU data was compared to OMC data based on marker clusters; and, second based on skin markers attached to anatomical landmarks. The first evaluation revealed means for RMSE and ROME for all joints and tasks below 3°. The more dynamic task, CMJ, revealed error measures approximately 1° higher than the remaining tasks. Mean CMC values ranged from 0.77 to 1 over all joint angles and all tasks. The second evaluation showed an increase in the RMSE of 2.28°- 2.58° on average for all joints and tasks. Hip flexion revealed the highest average RMSE in all tasks (4.87°- 8.27°). The present study revealed a valid IMU-based approach for the measurement of 3D joint kinematics in functional movements of varying demands. The high validity of the results encourages further development and the extension of the present approach into clinical settings.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In variables like head angle or knee in the frontal plane, IMUs represent a more robust alternative, as they provide high-frequency, three-dimensional orientation data that is independent of camera position and field of view.
“In variables like head angle or knee in the frontal plane IMUs represent a more robust alternative [60,61,62], as they provide high-frequency, three-dimensional orientation data that is independent of camera position and field of view.”
From Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women (2026) · cites this paper as [61]
The Abstract and Discussion §4.1 support IMUs as a promising alternative for measuring 3D lower-extremity kinematics, including frontal-plane knee angles. But the study did not assess head angles or establish greater robustness due to independence from camera position or field of view. Methods §2.1 says both systems recorded at 60 Hz and that IMU calibration and initialization incorporated optical-motion-capture data. (LLM, conf=0.88)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 29,639 · see citing works
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · see citing works
Understanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,022 · see citing works
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 1,864 · cited 1× · see citing works
“This approach was deemed appropriate given that the mean of a similar number of movement cycles is usually examined in clinical measurements [40].”
BackgroundHuman movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239 · see citing works
Human movement analysis using stereophotogrammetry
Cappozzo, A., Croce, U. D., Leardini, A., & Chiari, L. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.01.010 · Cited by 840 · see citing works
A new anatomically based protocol for gait analysis in children
Leardini, A., SAWACHA, Z., Paolini, G., Ingrosso, S., Nativo, R., & Benedetti, M. G. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.12.018 · Cited by 495 · see citing works
Alternative Countermovement-Jump Analysis to Quantify Acute Neuromuscular Fatigue
Gathercole, R. J., Sporer, B. C., Stellingwerff, T., & Sleivert, G. G. (2014) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2013-0413 · Cited by 447 · see citing works
Cook, G., Burton, L., Hoogenboom, B. J., et al. (2014) · PubMed · Cited by 387 · see citing works
Quantification of soft tissue artifact in lower limb human motion analysis: A systematic review
Peters, A., Galna, B., Sangeux, M., Morris, M. E., & Baker, R. J. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.09.004 · Cited by 368 · see citing works
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329 · see citing works
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318 · see citing works
Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics
Zhang, J.-T., Novak, A. C., Brouwer, B., & Li, Q. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/n63 · Cited by 314 · see citing works
MANAL, K. T., McClay, I. S., Stanhope, S. J., et al. (2000) · Gait & Posture · doi:10.1016/s0966-6362(99)00042-9 · Cited by 284 · see citing works
Bergamini, E., Ligorio, G., Summa, A., Vannozzi, G., Cappozzo, A., & Sabatini, A. M. (2014) · Sensors · doi:10.3390/s141018625 · Cited by 267 · see citing works
Picerno, P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2016.11.008 · Cited by 237 · see citing works
‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors
Cutti, A. G., Ferrari, A., Garofalo, P., Raggi, M., Cappello, A., & Ferrari, A. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0545-x · Cited by 218 · see citing works
Analysis of Lower Limb Asymmetries by Isokinetic and Vertical Jump Tests in Soccer Players
Menzel, H.-J., Chagas, M. H., Szmuchrowski, L. A., et al. (2012) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318265a3c8 · Cited by 157 · see citing works
Kluge, F., Gaßner, H., Hannink, J., Pasluosta, C. F., Klucken, J., & Eskofier, B. M. (2017) · Sensors · doi:10.3390/s17071522 · Cited by 157 · see citing works
Ferrari, A., Cutti, A. G., & Cappello, A. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.02.009 · Cited by 149 · see citing works
Nüesch, C., Roos, E., Pagenstert, G., & Mündermann, A. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.03.015 · Cited by 145 · see citing works
Fiorentino, N. M., Atkins, P. R., Kutschke, M. J., Goebel, J., Foreman, K. B., & Anderson, A. E. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.03.033 · Cited by 127 · see citing works
Detecting Dementia Through Interactive Computer Avatars
Tanaka, H., Adachi, H., Ukita, N., Ikeda, M., Kazui, H., Kudo, T., & Nakamura, S. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2752152 · Cited by 127 · see citing works
Countermovement jump performance assessment using a wearable 3D inertial measurement unit
Picerno, P., Camomilla, V., & Capranica, L. (2010) · Journal of Sports Sciences · doi:10.1080/02640414.2010.523089 · Cited by 125 · see citing works
Thewlis, D., Bishop, C., Daniell, N., et al. (2013) · Journal of Applied Biomechanics · doi:10.1123/jab.29.1.112 · Cited by 122 · see citing works
Cappello, A., Stagni, R., Fantozzi, S., & Leardini, A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.846728 · Cited by 112 · see citing works
Robert‐Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.02.029 · Cited by 108 · see citing works
Teufl, W., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2018) · Sensors · doi:10.3390/s18071980 · Cited by 105 · see citing works
Self-citationOn Inertial Body Tracking in the Presence of Model Calibration Errors
Miezal, M., Taetz, B., & Bleser, G. (2016) · Sensors · doi:10.3390/s16071132 · Cited by 99 · see citing works
Self-citationBenoit, D. L., Damsgaard, M., & Andersen, M. S. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.02.050 · Cited by 98 · see citing works
Study of the motion artefacts of skin-mounted inertial sensors under different attachment conditions
Forner‐Cordero, A., Mateu-Arce, M., Forner‐Cordero, I., Alcántara, E., Moreno, J. C., & Pons, J. L. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/4/n01 · Cited by 88 · see citing works
Teufl, W., Taetz, B., Miezal, M., Lorenz, M., Pietschmann, J., Jöllenbeck, T., Fröhlich, M., & Bleser, G. (2019) · Sensors · doi:10.3390/s19225006 · Cited by 82 · see citing works
Self-citationThe Importance of Range of Motion after Total Hip Arthroplasty
DAVIS, K. E., Ritter, M. A., Berend, M. E., & Meding, J. B. (2007) · Clinical Orthopaedics and Related Research · doi:10.1097/blo.0b013e31815c5a64 · Cited by 81 · see citing works
Weeks, B. K., Carty, C. P., & Horan, S. A. (2012) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-13-207 · Cited by 80 · see citing works
Joint Inertial Sensor Orientation Drift Reduction for Highly Dynamic Movements
Fasel, B., Spörri, J., Chardonnens, J., Kröll, J., Müller, E. A., & Aminian, K. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2659758 · Cited by 75 · see citing works
Automated Assessment of Dynamic Knee Valgus and Risk of Knee Injury During the Single Leg Squat
Kianifar, R., Lee, A. W., Raina, S. M., & Kulić, D. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2736559 · Cited by 73 · see citing works
Lebleu, J., Gosseye, T. P., Detrembleur, C., Mahaudens, P., Cartiaux, O., & Penta, M. (2020) · Sensors · doi:10.3390/s20030715 · Cited by 69 · see citing works
Fasel, B., Spörri, J., Schütz, P., Lorenzetti, S., & Aminian, K. (2017) · PLoS ONE · doi:10.1371/journal.pone.0181446 · Cited by 68 · see citing works
Lebel, K., Boissy, P., Nguyen, H., & Duval, C. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0347-6 · Cited by 65 · see citing works
Correlation between Ground Reaction Force and Tibial Acceleration in Vertical Jumping
Elvin, N. G., Elvin, A. A., & ARNOCZKY, S. P. (2007) · Journal of Applied Biomechanics · doi:10.1123/jab.23.3.180 · Cited by 63 · see citing works
MANAL, K. T., McClay, I. S., Richards, J., et al. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00174-6 · Cited by 63 · see citing works
Soft tissue artifact compensation by linear 3D interpolation and approximation methods
Dumas, R., & Chèze, L. L. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.006 · Cited by 48 · see citing works
Vertical jumping biomechanical evaluation through the use of an inertial sensor-based technology
Setuain, I., Martinikorena, J., González‐Izal, M., Martínez-Ramírez, A., Gómez, M., Alfaro-Adrian, J., & Izquierdo, M. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1075057 · Cited by 44 · see citing works
McGinnis, R. S., Cain, S. M., Davidson, S. P., Vitali, R. V., Perkins, N. C., & McLean, S. G. (2015) · Sports Engineering · doi:10.1007/s12283-015-0185-3 · Cited by 43 · see citing works
Barré, A., Jolles, B. M., Theumann, N. H., & Aminian, K. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.04.007 · Cited by 41 · see citing works
Baldon, R. D. M., Piva, S. R., Silva, R. S., & Serrão, F. V. (2015) · The American Journal of Sports Medicine · doi:10.1177/0363546515574690 · Cited by 39 · see citing works
Miezal, M., Taetz, B., & Bleser, G. (2017) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2017.7989371 · Cited by 39 · see citing works
Self-citationMcPherson, A. L., Dowling, B., Tubbs, T. G., & Paci, J. M. (2016) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2016.04.001 · Cited by 38 · see citing works
Validation of a Device to Measure Knee Joint Angles for a Dynamic Movement
Ajdaroski, M., Tadakala, R., Nichols, L., & Esquivel, A. O. (2020) · Sensors · doi:10.3390/s20061747 · Cited by 33 · see citing works
Cockcroft, J., Louw, Q. A., & Baker, R. J. (2016) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2016.1157865 · Cited by 28 · see citing works
Bonnet, V., Richard, V., Camomilla, V., et al. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.04.033 · Cited by 26 · see citing works
van der Straaten, R., Wesseling, M., Jonkers, I., Vanwanseele, B., Bruijnes, A. K. B. D., Malcorps, J., Bellemans, J., Truijen, J., Baets, L. D., & Timmermans, A. A. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00694-2 · Cited by 26 · see citing works
Generalizations of Euler decomposition and their applications
Eie, M., & Wei, C.-S. (2013) · Journal of Number Theory · doi:10.1016/j.jnt.2013.01.010 · Cited by 17 · see citing works
Brauner, T., Wearing, S. C., Rämisch, E., Zillober, M., & Horstmann, T. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.06.003 · Cited by 16 · see citing works
van der Straaten, R., Wesseling, M., Jonkers, I., Vanwanseele, B., Bruijnes, A. K. B. D., Malcorps, J., Bellemans, J., Truijen, J., Baets, L. D., & Timmermans, A. A. A. (2020) · PLoS ONE · doi:10.1371/journal.pone.0232513 · Cited by 8 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [48]Fiorentino NM, Atkins PR, Kutschke MJ, Goebel JM, Foreman KB, Anderson AE. Soft tissue artifact causes significant errors in the calculation of joint angles and range of motion at the hip. Gait Posture. 2017; 55: 184– 190. 10.1016/j.gaitpost.2017.03.033 28475981 PMC9840870 · DOI
Cited by
Sorted by citations
Vicente-Loren, C., Lucha-López, M. O., Monti-Ballano, S., Hijazo-Larrosa, S., Vicente-Pina, L., Ferrández-Laliena, L., Tricás-Moreno, J. M., & Hidalgo-García, C. (2026) · Sensors · doi:10.3390/s26123749
- Authors
- Teufl, W., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G.
- Affiliations
- University of Kaiserslautern (DE)
- Corresponding author
- Teufl, Wolfgang
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2019-02-28
- Volume
- 14
- Issue
- 2
- Pages
- e0213064
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC6394915
- OpenAlex
- W2918167402
- Cited by
- 129
- References
- 55
- Citations by year
- 2026: 12 · 2025: 13 · 2024: 15 · 2023: 22 · 2022: 22 · 2021: 20 · 2020: 21 · 2019: 4
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Publication Server of Kaiserslautern University of Technology (Kaiserslautern University of Technology) (submittedVersion)
- Funders
- Bundesministerium für Bildung und Forschung (16SV7115, 03IHS075B)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Keywords
- inertial measurement unit, 3D joint kinematics, sensor fusion, lower extremity, squatting, single-leg squat, countermovement jump, optical motion capture, measurement validity, hip flexion, dynamic movement, physiotherapy
- MeSH terms
- Adult, Algorithms, Biomechanical Phenomena, Female, Humans, Joints, Male, Models, Biological, Movement, Sports, Sports Medicine, Range of Motion, Articular, Imaging, Three-Dimensional, Physical Therapy Modalities, Young Adult, Fiducial Markers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review