Wearable inertial sensors in swimming motion analysis: a systematic review
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The use of contemporary technology is widely recognised as a key tool for enhancing competitive performance in swimming. Video analysis is traditionally used by coaches to acquire reliable biomechanical data about swimming performance; however, this approach requires a huge computational effort, thus introducing a delay in providing quantitative information. Inertial and magnetic sensors, including accelerometers, gyroscopes and magnetometers, have been recently introduced to assess the biomechanics of swimming performance. Research in this field has attracted a great deal of interest in the last decade due to the gradual improvement of the performance of sensors and the decreasing cost of miniaturised wearable devices. With the aim of describing the state of the art of current developments in this area, a systematic review of the existing methods was performed using the following databases: PubMed, ISI Web of Knowledge, IEEE Xplore, Google Scholar, Scopus and Science Direct. Twenty-seven articles published in indexed journals and conference proceedings, focusing on the biomechanical analysis of swimming by means of inertial sensors were reviewed. The articles were categorised according to sensor's specification, anatomical sites where the sensors were attached, experimental design and applications for the analysis of swimming performance. Results indicate that inertial sensors are reliable tools for swimming biomechanical analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Journal of Sports Science and Medicine
(2021) · Journal of Sports Science and Medicine · doi:10.52082/jssm · Cited by 1,289
Journal of Sports Science and Medicine
Stewart, M. (2014) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2014.06.007 · Cited by 1,227
Swimming constraints and arm coordination
Seifert, L., Chollet, D., & Rouard, A. H. (2006) · Human Movement Science · doi:10.1016/j.humov.2006.09.003 · Cited by 172 · cited 1×
“Starting from the calculation of specific temporal features in kinematic signals, Dadashi, Crettenand, et al. (2013) were able to estimate the index of coordination as defined by Seifert, Chollet, and Rouard (2007).”
BackgroundThe use of a single inertial sensor to identify stride, step, and stance durations of running gait
Lee, J. B., Mellifont, R. B., & Burkett, B. J. (2009) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2009.01.005 · Cited by 164
Bergamini, E., Picerno, P., Pillet, H., Natta, F., Thoreux, P., & Camomilla, V. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.12.020 · Cited by 151 · cited 2×
“The validation of sensors has been widely carried out in running (Bergamini et al., 2012; Lee, Mellifont, & Burkett, 2010) and jumping (Picerno, Camomilla, & Capranica, 2011).”
Callaway, A. J., Cobb, J. E., & Jones, I. (2009) · International Journal of Sports Science & Coaching · doi:10.1260/1747-9541.4.1.139 · Cited by 131 · cited 6×
“Marker tracking is the most accurate and comprehensible method for swimming motion analysis, which provides relevant data to coaches and athletes (Callaway et al., 2009); however, making this process fully automatic is difficult.”
BackgroundMethodInfluentialCountermovement jump performance assessment using a wearable 3D inertial measurement unit
Picerno, P., Camomilla, V., & Capranica, L. (2011) · Journal of Sports Sciences · doi:10.1080/02640414.2010.523089 · Cited by 124
Front-Crawl Instantaneous Velocity Estimation Using a Wearable Inertial Measurement Unit
Dadashi, F., Crettenand, F., Millet, G. P., & Aminian, K. (2012) · Sensors · doi:10.3390/s121012927 · Cited by 122 · cited 2×
“Recently, Stamm et al. (2011) and Dadashi et al. (2012) have proposed two methods to estimate front crawl velocity from a single body-worn IMU mounted at sacrum level.”
BackgroundSwimming performance and technique evaluation with wearable acceleration sensors
Bächlin, M., & Tröster, G. (2011) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2011.05.003 · Cited by 112 · cited 3×
“Bächlin, Förster, & Tröster (2009) have developed a method named “SwimMaster” with the potential to give feedback through processing the measured accelerations (Bächlin & Tröster, 2009, 2012).”
BackgroundMethodEfficient accelerometer-based swimming exercise tracking
Siirtola, P., Laurinen, P., Röning, J., & Kinnunen, H. O. (2011) · IEEE Symposium on Computational Intelligence and Data Mining (CIDM) · doi:10.1109/cidm.2011.5949430 · Cited by 100
Markerless analysis of front crawl swimming
Ceseracciu, E., SAWACHA, Z., Fantozzi, S., Cortesi, M., Gatta, G., Corazza, S., & Cobelli, C. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.06.003 · Cited by 96 · cited 1×
“Traditionally, motion measurements during swimming have been performed using video analysis method as gold standard (Ceseracciu et al., 2011; McCabe, Psycharakis, & Sanders, 2011; McCabe & Sanders, 2012; Vezos et al., 2007).”
MethodSelf-citationAutomatic front-crawl temporal phase detection using adaptive filtering of inertial signals
Dadashi, F., Crettenand, F., Millet, G. P., Seifert, L., Komar, J., & Aminian, K. (2013) · Journal of Sports Sciences · doi:10.1080/02640414.2013.778420 · Cited by 91
Jones, T. B., & Nenadic, N. G. (2013) · Cambridge University Press eBooks · doi:10.1017/cbo9781139032605 · Cited by 83
Velocity profiling using inertial sensors for freestyle swimming
Stamm, A., James, D. A., & Thiel, D. V. (2012) · Sports Engineering · doi:10.1007/s12283-012-0107-6 · Cited by 76 · cited 3×
“…I, adopted on-node acquisition, utilising several memory devices such as flash memory and SD cards with a storage capacity ranging from 128 Mb to 1 Gb (Ohgi, 2002; Stamm et al., 2013) reporting also acquisition durations up to 200 h, depending upon the set sampling frequency (James et al., 2011).”
BackgroundMethodEmbedded programming and real-time signal processing of swimming strokes
Sage, T. L., Bindel, A., CONWAY, P. P., Justham, L., Slawson, S., & West, A. A. (2011) · Sports Engineering · doi:10.1007/s12283-011-0070-7 · Cited by 72 · cited 2×
“Several studies included only one participant in monitoring the feasibility of using IMUs for performance (Hagem, Thiel, et al., 2013; James et al., 2011; Le Sage et al., 2010b, 2011).”
BackgroundThe Application of Inertial Sensors in Elite Sports Monitoring
James, D. A. (2006) · Springer eBooks · doi:10.1007/978-0-387-45951-6_52 · Cited by 63 · cited 2×
“, 2009; Davey, 2004; James, Moritz, & Haake, 2006); ii) does not bother the swimmers or influence his/her action (Davey, 2004; James et al., 2006); and iii) does not limit the swimmer’s free motion (Bächlin & Tröster, 2012).”
BackgroundValidation of GPS and accelerometer technology in swimming
Beanland, E., Main, L. C., Aisbett, B., Gastin, P. B., & Netto, K. (2013) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2013.04.007 · Cited by 60 · cited 1×
“This in-field monitoring typically includes stroke counts, measurement of time durations and identification of the main phases (Beanland et al., 2013; Hagem, O’Keefe, et al., 2013).”
Validity and reliability of kick count and rate in freestyle using inertial sensor technology
Fulton, S. K., Pyne, D. B., & Burkett, B. J. (2009) · Journal of Sports Sciences · doi:10.1080/02640410902998247 · Cited by 60 · cited 3×
“The few commercial systems that are available to support measurements in the aquatic environment work by inserting the IMU in a waterproof, or nominally waterproof, case (Fulton et al., 2009a).”
BackgroundAnderson, R. E., Harrison, A. J., & Lyons, G. M. (2005) · Sports Biomechanics · doi:10.1080/14763140508522862 · Cited by 59
Chakravorti, N., Sage, T. L., Slawson, S., CONWAY, P. P., & West, A. A. (2013) · IEEE Transactions on Human-Machine Systems · doi:10.1109/tsmc.2012.2235428 · Cited by 56 · cited 2×
“…the relevant phases for each swimming style (Ohgi et al., 2003), then calculating of temporal parameters such as time durations (Bächlin & Tröster, 2012; Dadashi, Arami, et al., 2013; Hagem, Thiel, et al., 2013), or stroke and kick frequencies (Fulton et al., 2009b, 2011; Chakravorti et al., 2013).”
BackgroundStroke phase discrimination in breaststroke swimming using a tri-axial acceleration sensor device
Ohgi, Y., Ichikawa, H., Homma, M., & Miyaji, C. (2003) · Sports Engineering · doi:10.1007/bf02903532 · Cited by 54 · cited 2×
“This effort involved first defining the relevant phases for each swimming style (Ohgi et al., 2003), then calculating of temporal parameters such as time durations (Bächlin & Tröster, 2012; Dadashi, Arami, et al.”
BackgroundMotion analysis of front crawl swimming applying CAST technique by means of automatic tracking
Ceccon, S., Ceseracciu, E., SAWACHA, Z., Gatta, G., Cortesi, M., Cobelli, C., & Fantozzi, S. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.729134 · Cited by 54 · cited 2×
“…2014 Taylor & Francis tracking procedure for estimating the position of given points of interest (typically anatomical landmarks) using algorithms specifically developed to extract performance-related biomechanical variables (Ceccon et al., 2013; Pansiot et al., 2010).”
MethodSelf-citationKinematic differences between front crawl sprint and distance swimmers at a distance pace
McCabe, C. B., & Sanders, R. H. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.660186 · Cited by 53 · cited 1×
“Traditionally, motion measurements during swimming have been performed using video analysis method as gold standard (Ceseracciu et al., 2011; McCabe, Psycharakis, & Sanders, 2011; McCabe & Sanders, 2012; Vezos et al., 2007).”
MethodSelf Contained Adaptable Optical Wireless Communications System for Stroke Rate During Swimming
Hagem, R. M., O’Keefe, S. G., Fickenscher, T., & Thiel, D. V. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2262933 · Cited by 49
Effectiveness of an automatic tracking software in underwater motion analysis.
Magalhães, F. A., SAWACHA, Z., Michele, R. D., Cortesi, M., Gatta, G., & Fantozzi, S. (2013) · Europe PMC (PubMed Central) · Cited by 47
Self-citationDadashi, F., Arami, A., Crettenand, F., Millet, G. P., Komar, J., Seifert, L., & Aminian, K. (2013) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2013.6575461 · Cited by 45
Quantifying freestyle kick-count and kick-rate patterns in Paralympic swimming
Fulton, S. K., Pyne, D. B., & Burkett, B. J. (2009) · Journal of Sports Sciences · doi:10.1080/02640410903062936 · Cited by 42 · cited 3×
“The few commercial systems that are available to support measurements in the aquatic environment work by inserting the IMU in a waterproof, or nominally waterproof, case (Fulton et al., 2009a).”
BackgroundSensor fusion: let's enhance the performance of performance enhancement
Lee, J. B., Ohgi, Y., & James, D. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.04.136 · Cited by 27 · cited 1×
“Recently, Lee et al. (2012) proposed a sensor fusion approach that aimed at conjugating the novelty of IMU technology with the traditional video capture to benefit from the advantages of both.”
BackgroundDesign and implementation of a user-centric swimming performance monitoring tool
Mullane, S. L., Chakravorti, N., Conway, P. P., & West, A. A. (2011) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/1754337111405271 · Cited by 16
A Multi-sensor System for Monitoring the Performance of Elite Swimmers
Sage, T. L., Bindel, A., CONWAY, P. P., Justham, L., Slawson, S., Webster, J., & West, A. A. (2012) · Communications in computer and information science · doi:10.1007/978-3-642-25206-8_23 · Cited by 13 · cited 1×
“…(e.g. video analysis, force sensors) and user-friendly interfaces are designed (Khoo, Lee, Senanayake, & Wilson 2009), the acceptability of IMU-based monitoring systems (Le Sage et al., 2012; Mullane, Chakravorti, & Conway, 2011) is expected to meet the expectations of both coaches and athletes.”
Background
Cited by
Colyer, S. L., Evans, M., Cosker, D. P., & Salo, A. I. T. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0139-y · Cited by 629
Camomilla, V., Bergamini, E., Fantozzi, S., & Vannozzi, G. (2018) · Sensors · doi:10.3390/s18030873 · Cited by 591
Self-citationUnderwater Internet of Things in Smart Ocean: System Architecture and Open Issues
Qiu, T., Zhao, Z., Zhang, T., Chen, C., & Chen, C. L. P. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2946618 · Cited by 393
Cust, E. E., Sweeting, A. J., Ball, K., & Robertson, S. (2019) · Journal of Sports Sciences · doi:10.1080/02640414.2018.1521769 · Cited by 324
Wearable Sensors for Real-Time Kinematics Analysis in Sports: A Review
Rana, M., & Mittal, V. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3019016 · Cited by 298
Metadata
- Authors
- Magalhaes, F. A. D., Vannozzi, G., Gatta, G., & Fantozzi, S.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2014-10-30
- Volume
- 33
- Issue
- 7
- Pages
- 732-745
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2042572748
- Cited by
- 164
- References
- 30
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.