Identifying waking time in 24-h accelerometry data in adults using an automated algorithm
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
As accelerometers are commonly used for 24-h measurements of daily activity, methods for separating waking from sleeping time are necessary for correct estimations of total daily activity levels accumulated during the waking period. Therefore, an algorithm to determine wake and bed times in 24-h accelerometry data was developed and the agreement of this algorithm with self-report was examined. One hundred seventy-seven participants (aged 40-75 years) of The Maastricht Study who completed a diary and who wore the activPAL3™ 24 h/day, on average 6 consecutive days were included. Intraclass correlation coefficient (ICC) was calculated and the Bland-Altman method was used to examine associations between the self-reported and algorithm-calculated waking hours. Mean self-reported waking hours was 15.8 h/day, which was significantly correlated with the algorithm-calculated waking hours (15.8 h/day, ICC = 0.79, P = < 0.001). The Bland-Altman plot indicated good agreement in waking hours as the mean difference was 0.02 h (95% limits of agreement (LoA) = -1.1 to 1.2 h). The median of the absolute difference was 15.6 min (Q1-Q3 = 7.6-33.2 min), and 71% of absolute differences was less than 30 min. The newly developed automated algorithm to determine wake and bed times was highly associated with self-reported times, and can therefore be used to identify waking time in 24-h accelerometry data in large-scale epidemiological studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marino, M., Li, Y., Rueschman, M. N., Winkelman, J. W., Ellenbogen, J. M., Solet, J. M., Dulin, H., Berkman, L. F., & Buxton, O. M. (2013) · Sleep · doi:10.5665/sleep.3142 · Cited by 1,056
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Lee, I.-M., & Shiroma, E. J. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093154 · Cited by 415
Tudor-Locke, C., Barreira, T. V., Schuna, J. M., Mire, E. F., & Katzmarzyk, P. T. (2014) · Applied Physiology Nutrition and Metabolism · doi:10.1139/apnm-2013-0173 · Cited by 285 · cited 2×
“Methods to determine sleep or time in bed using hip-worn or waist-worn accelerometers have been described before (Barreira et al., 2015; Hjorth et al., 2012; Kinder et al., 2012; Marino et al., 2013; Ray et al., 2014; Tracy et al., 2014; Tudor-locke et al., 2014), and some methods have been shown to be fairly accurate…”
MethodIdentifying Children’s Nocturnal Sleep Using 24-h Waist Accelerometry
BARREIRA, T. V., SCHUNA, J. M., MIRE, E. F., KATZMARZYK, P. T., CHAPUT, J.-P., LEDUC, G., & TUDOR-LOCKE, C. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000486 · Cited by 163 · cited 5×
“, 2014), and some methods have been shown to be fairly accurate (Barreira et al., 2015; Tracy et al., 2014).”
BackgroundMethodInfluentialHJORTH, M. F., CHAPUT, J.-P., DAMSGAARD, C. T., DALSKOV, S.-M., MICHAELSEN, K. F., TETENS, I., & SJÖDIN, A. (2012) · Sleep and Biological Rhythms · doi:10.1111/j.1479-8425.2012.00578.x · Cited by 106 · cited 3×
“Methods to determine sleep or time in bed using hip-worn or waist-worn accelerometers have been described before (Barreira et al., 2015; Hjorth et al., 2012; Kinder et al., 2012; Marino et al., 2013; Ray et al., 2014; Tracy et al., 2014; Tudor-locke et al., 2014), and some methods have been shown to be fairly accurate…”
BackgroundMethodSmith, L., Thomas, E. L., Bell, J. D., & Hamer, M. (2014) · BMJ Open · doi:10.1136/bmjopen-2014-005476 · Cited by 37 · cited 1×
“Another possibility to identify waking time is using a fixed-time window, which have been used in studies with a 24 h wear time protocol (De Decker et al., 2013; Smith et al., 2014, 2015).”
Method
Cited by
Considerations when using the activPAL monitor in field-based research with adult populations
Edwardson, C. L., Winkler, E. A. H., Bodicoat, D. H., Yates, T., Davies, M. J., Dunstan, D. W., & Healy, G. N. (2017) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2016.02.002 · Cited by 502
Grevendonk, L., Connell, N. J., McCrum, C., Fealy, C. E., Bilet, L., Bruls, Y. M. H., Mevenkamp, J., Schrauwen-Hinderling, V. B., Jörgensen, J. A., Moonen-Kornips, E., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24956-2 · Cited by 298
van der Berg, J. D., Stehouwer, C. D. A., Bosma, H., van der Velde, J. H. P. M., Willems, P. J. B., Savelberg, H. H. C. M., Schram, M. T., Sep, S. J. S., van der Kallen, C. J. H., Henry, R. M. A., et al. (2016) · Diabetologia · doi:10.1007/s00125-015-3861-8 · Cited by 299
Self-citationWinkler, E. A. H., Bodicoat, D. H., Healy, G. N., Bakrania, K., Yates, T., Owen, N., Dunstan, D. W., & Edwardson, C. L. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/10/1653 · Cited by 287
Stamatakis, E., Koster, A., Hamer, M., Rangul, V., Lee, I.-M., Bauman, A. E., Atkin, A. J., Aadahl, M., Matthews, C. E., Mork, P. J., et al. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2019-100786 · Cited by 106
Self-citation
Metadata
- Authors
- van der Berg, J. D., Willems, P. J. B., van der Velde, J. H. P. M., Savelberg, H. H. C. M., Schaper, N. C., Schram, M. T., Sep, S. J. S., Dagnelie, P. C., Bosma, H., Stehouwer, C. D. A., & Koster, A.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2016-02-02
- Volume
- 34
- Issue
- 19
- Pages
- 1867-1873
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2305555656
- Cited by
- 115
- References
- 7
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identifying waking time in 24-h accelerometry data in adults using an automated algorithm. https://app.cochat.ai/papers/10.1080/02640414.2016.1140908
- The paper
- van der Berg, J. D., Willems, P. J. B., van der Velde, J. H. P. M., Savelberg, H. H. C. M., Schaper, N. C., Schram, M. T., Sep, S. J. S., Dagnelie, P. C., Bosma, H., Stehouwer, C. D. A., & Koster, A. (2016). Identifying waking time in 24-h accelerometry data in adults using an automated algorithm. Journal of Sports Sciences. https://doi.org/10.1080/02640414.2016.1140908
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.