Magnetically mediated hyperthermia: current status and future directions
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The use of hyperthermia in the treatment of cancers is appealing because, as a physical therapy, hyperthermia would have far fewer restrictive side effects than chemotherapy and radiotherapy, and it could be used in combination with these therapies. However, the currently available modalities of hyperthermia are often limited by their inability to selectively target tumour tissue and, hence, they carry a high risk of collateral organ damage or they deposit heat in a very localized manner which can result in under-treatment of a tumour. Magnetically mediated hyperthermia (MMH) has the potential to address these shortcomings. MMH consists of the localization of magnetic particles or seeds within tumour tissue followed by exposure to an externally applied alternating magnetic field to cause them to heat. Since this concept was introduced (over 40 years ago), MMH has evolved into four general sub-classes: arterial embolization hyperthermia (AEH), direct injection hyperthermia (DIH), intracellular hyperthermia (IH) and interstitial implant hyperthermia (IIH). It is the purpose of this article to review these four sub-classes in terms of experimental or clinical results, advantages, limitations and current status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The blood supply of neoplasms in the liver.
Breedis, C., & Young, G. P. (1954) · PubMed · Cited by 1,455
Selective Inductive Heating of Lymph Nodes
GILCHRIST, R. K., MEDAL, R., SHOREY, W. D., HANSELMAN, R. C., PARROTT, J. C., & TAYLOR, C. B. (1957) · Annals of Surgery · doi:10.1097/00000658-195710000-00007 · Cited by 1,091
Jordan, A., Scholz, R., Maier-Hauff, K., Johannsen, M., Wust, P., Nadobny, J., Schirra, H., Schmidt, H., Deger, S., Loening, S., et al. (2001) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(00)01239-7 · Cited by 731
Jordan, A., Wust, P., Fählin, H., John, W., Hinz, A., & Felix, R. (1993) · International Journal of Hyperthermia · doi:10.3109/02656739309061478 · Cited by 694
Jordan, A., Scholz, R., Wust, P., Schirra, H., Schiestel, T., Schmidt, H., & Felix, R. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00558-7 · Cited by 521
The current and potential role of hyperthermia in radiotherapy
Overgaard, J. (1989) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(89)90470-7 · Cited by 506
Effects of Magnetic Fluid Hyperthermia (MFH) on C3H mammary carcinoma in vivo
Jordan, A., Scholz, R., Wust, P., Fähling, H., Krause, J., Wlodarczyk, W., Sander, B., Vogl, T., & Felix, R. (1997) · International Journal of Hyperthermia · doi:10.3109/02656739709023559 · Cited by 325
Intracellular Hyperthermia for Cancer Using Magnetite Cationic Liposomes: An in vivo Study
Yanase, M., Shinkai, M., Honda, H., Wakabayashi, T., Yoshida, J., & Kobayashi, T. (1998) · Japanese Journal of Cancer Research · doi:10.1111/j.1349-7006.1998.tb00586.x · Cited by 322
C.F. Chan, D., B. Kirpotin, D., & A. Bunn, P. (1993) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(93)91113-l · Cited by 319
Gordon, R. T., Hines, J. R., & Gordon, D. (1979) · Medical Hypotheses · doi:10.1016/0306-9877(79)90063-x · Cited by 310
Jordan, A., Wust, P., Scholz, R., Tesche, B., Fähling, H., Mitrovics, T., Vogl, T., Cervós-navarro, J., & Felix, R. (1996) · International Journal of Hyperthermia · doi:10.3109/02656739609027678 · Cited by 259
Hilger, I., Andrä, W., Hergt, R., Hiergeist, R., Schubert, H., & Kaiser, W. A. (2001) · Radiology · doi:10.1148/radiology.218.2.r01fe19570 · Cited by 224
Intracellular hyperthermia for cancer using magnetite cationic liposomes
Shinkai, M., Yanase, M., Suzuki, M., Honda, H., Wakabayashi, T., Yoshida, J., & Kobayashi, T. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00586-1 · Cited by 211
Vascularization of small liver metastases
Archer, S. G., & Gray, B. N. (1989) · Journal of British Surgery · doi:10.1002/bjs.1800760607 · Cited by 158
Self-citationEmami, B., Scott, C., Perez, C. A., Asbell, S. O., Swift, P. S., Grigsby, P. W., Montesano, A. T., Rubin, P., Curran, W. J., DelRowe, J. D., et al. (1996) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)02137-x · Cited by 148
Herman, T. S., Teicher, B. A., Jochelson, M. S., Clark, J., Svensson, G. K., & Coleman, C. N. (1988) · International Journal of Hyperthermia · doi:10.3109/02656738809029305 · Cited by 147
Targeting liver tumors with hyperthermia: Ferromagnetic embolization in a rabbit liver tumor model
Moroz, P., Jones, S. K., Winter, J., & Gray, B. N. (2001) · Journal of Surgical Oncology · doi:10.1002/jso.1118 · Cited by 118
Self-citationPreparation of Tumor-Specific Magnetoliposomes and Their Application for Hyperthermia.
Biao, L., Shinkai, M., Kitade, T., Honda, H., Yoshida, J., Wakabayashi, T., & Kobayashi, T. (2001) · JOURNAL OF CHEMICAL ENGINEERING OF JAPAN · doi:10.1252/jcej.34.66 · Cited by 101
Minamimura, T., Sato, H., Kasaoka, S., Saito, T., Ishizawa, S., Takemori, S., Tazawa, K., & Tsukada, K. (2000) · International Journal of Oncology · doi:10.3892/ijo.16.6.1153 · Cited by 90
Development of intra-arterial hyperthermia using a dextran-magnetite complex
Mitsumori, M., Hiraoka, M., Shibata, T., Okuno, Y., Masunaga, S.-I., Koishi, M., Okajima, K., Nagata, Y., Nishimura, Y., Abe, M., et al. (1994) · International Journal of Hyperthermia · doi:10.3109/02656739409012371 · Cited by 89
Suzuki, M., Shinkai, M., Kamihira, M., & Kobayashi, T. (1995) · Biotechnology and Applied Biochemistry · doi:10.1111/j.1470-8744.1995.tb00339.x · Cited by 85
Targeted hyperthermia using dextran magnetite complex: a new treatment modality for liver tumors.
Mitsumori, M., Hiraoka, M., Shibata, T., Okuno, Y., Nagata, Y., Nishimura, Y., Abe, M., Hasegawa, M., Nagae, H., & Ebisawa, Y. (1996) · PubMed · Cited by 75
Induction of apoptotic cell DNA fragmentation in human cells after treatment with hyperthermia
Fairbairn, J. J., Khan, M. W., Ward, K. J., Loveridge, B. W., Fairbairn, D. W., & O'Neill, K. L. (1995) · Cancer Letters · doi:10.1016/0304-3835(94)03668-9 · Cited by 65
Treatment of experimental rabbit liver tumours by selectively targeted hyperthermia
Jones, S. K., Winter, J., & Gray, B. N. (2002) · International Journal of Hyperthermia · doi:10.1080/02656730110103519 · Cited by 59
Self-citationThermomagnetic surgery for cancer
Rand, R. W., Snow, H. D., Elliott, D. G., & Snyder, M. (1981) · Applied Biochemistry and Biotechnology · doi:10.1007/bf02798277 · Cited by 44
Archer, S. G., & Gray, B. N. (1990) · The American Journal of Surgery · doi:10.1016/s0002-9610(05)81228-0 · Cited by 44
Self-citationThe effect of tumour size on ferromagnetic embolization hyperthermia in a rabbit liver tumour model
Moroz, P., Jones, S. K., & Gray, B. N. (2002) · International Journal of Hyperthermia · doi:10.1080/02656730110095609 · Cited by 42
Self-citationHyperthermia in cancer therapy: current status
Anderson, R. L., & Kapp, D. S. (1990) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1990.tb120955.x · Cited by 37
Thermomagnetic surgery for cancer
Rand, R. W., Snow, H. D., & Brown, W. J. (1982) · Journal of Surgical Research · doi:10.1016/0022-4804(82)90026-9 · Cited by 34
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Self-citationApplications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Magnetic nanoparticle design for medical diagnosis and therapy
Mornet, S., Vasseur, S., Grasset, F., & Duguet, E. (2004) · Journal of Materials Chemistry · doi:10.1039/b402025a · Cited by 1,745
Metadata
- Authors
- Moroz, P., Jones, S. K., & Gray, B. N.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 18
- Issue
- 4
- Pages
- 267-284
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2059527518
- Cited by
- 538
- References
- 29
- FWCI
- 10.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.