Electromagnetic Heating of Breast Tumors in Interventional Radiology: In Vitro and in Vivo Studies in Human Cadavers and Mice
Abstract
PURPOSE: To assess relevant parameters for the minimally invasive elimination of breast tumors by using a selective application of magnetite and exposure of the breast to an alternating magnetic field. MATERIALS AND METHODS: The specific absorption rate (SAR) of different magnetite samples was determined calorimetrically. Temperature elevations based on magnetite mass (7-112 mg) and magnetic field amplitude (1.2-6.5 kA/m frequency, 400 kHz) were investigated by using human breast tissue. Parameter combinations (21 mg +/- 9 [SD], 242-second magnetic field exposure, 6.5-kA/m amplitude) were tested in 10 immunodeficient mice bearing human adenocarcinomas (MX-1 cells). Histologic sections of heated tumor tissue were analyzed. RESULTS: SAR data of different magnetite particle types ranged from 3 to 211 W/g. Temperature elevation (DeltaT) as a function of the magnetite mass increased linearly up to 28 mg; at higher masses, a saturation of DeltaT was observed at nearly 88 degrees C. The dependence of DeltaT on magnetic field amplitude (H) revealed a third-order power law: DeltaT = 0.26 degrees C/(kA/m)(3). H(3), with r(2) = 0.95. A mean temperature of 71 degrees C +/- 8 was recorded in the tumor region at the end of magnetic field exposure of the mice. Typical macroscopic findings included tumor shrinkage after heating. Histologically nuclear degenerations were observed in heated malignant cells. CONCLUSION: Magnetic heating of breast tumors is a promising technique for future interventional radiologic treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marchal, G., Van Hecke, P., Demaerel, P., Decrop, E., Kennis, C., Baert, A., & van der Schueren, E. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.4.771 · Cited by 122
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Ferrite-based magnetic nanofluids used in hyperthermia applications
Sharifi, I., Shokrollahi, H., & Amiri, S. (2012) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2011.10.017 · Cited by 759
Magnetically mediated hyperthermia: current status and future directions
Moroz, P., Jones, S. K., & Gray, B. N. (2002) · International Journal of Hyperthermia · doi:10.1080/02656730110108785 · Cited by 538
Electromagnetic activation of shape memory polymer networks containing magnetic nanoparticles
Schmidt, A. M. (2006) · Macromolecular Rapid Communications · doi:10.1002/marc.200600225 · Cited by 518
Metadata
- Authors
- Hilger, I., Andrä, W., Hergt, R., Hiergeist, R., Schubert, H., & Kaiser, W. A.
- Venue
- Radiology
- Published
- 2001-02
- Volume
- 218
- Issue
- 2
- Pages
- 570-575
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2163893690
- Cited by
- 224
- References
- 1
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electromagnetic Heating of Breast Tumors in Interventional Radiology: In Vitro and in Vivo Studies in Human Cadavers and Mice. https://app.cochat.ai/papers/10.1148/radiology.218.2.r01fe19570
- The paper
- Hilger, I., Andrä, W., Hergt, R., Hiergeist, R., Schubert, H., & Kaiser, W. A. (2001). Electromagnetic Heating of Breast Tumors in Interventional Radiology: In Vitro and in Vivo Studies in Human Cadavers and Mice. Radiology. https://doi.org/10.1148/radiology.218.2.r01fe19570
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.