Magnetic resonance temperature imaging
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Continuous, real-time, 3D temperature mapping during a hyperthermic procedure may provide (i) enhanced safety by visualizing temperature maps in and around the treated region, (ii) improved efficiency by adapting local energy deposition with feedback coupling algorithms and (iii) therapy end-points based on the accumulated thermal dose. Non-invasive mapping of temperature changes can be achieved with MRI and may be based on temperature dependent MRI parameters. The excellent linearity of the temperature dependency of the proton resonance frequency (PRF) and its near-independence with respect to tissue type make the PRF-based methods the preferred choice for many applications, in particular at mid- to-high field strength (> or =0.5 T). The PRF methods employ RF-spoiled gradient echo imaging methods and incorporate fat suppression techniques for most organs. A standard deviation of less than 1 degrees C, for a temporal resolution below 1 s and a spatial resolution of approximately 2 mm is feasible for immobile tissues. Special attention is paid to methods for reducing artifacts in MR temperature mapping caused by intra-scan and inter-scan motion and motion and temperature-induced susceptibility effects in mobile tissues. Real-time image processing and visualization techniques, together with accelerated MRI acquisition techniques, are described because of their potential for therapy guidance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1981) · Cited by 11,963
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Visual pattern recognition by moment invariants
Hu, M.-K. (1962) · IEEE Transactions on Information Theory · doi:10.1109/tit.1962.1057692 · Cited by 7,546 · cited 1×
“Global transformation estimation using: (a) principal axes and moments based methods (rigid motions are estimated with the spatial distribution of their mass [61]); (b) Fourier-based image registration algorithm (the properties of invariance in rotation and translation are used [62]); this method can register 2D image…”
MethodHorn, B. K., & Schunck, B. G. (1981) · SPIE Proceedings · doi:10.1117/12.965761 · Cited by 7,394 · cited 1×
“A regularity constraint is also required, like (1) local regularity constraint that may optimize some local energy expression [66] or (2) global regularity constraint which attempts to minimize a global energy function [67]).”
BackgroundBrain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483 · cited 1×
“related to changes in the concentration of deoxyhemoglobin during the therapy, similar to the BOLD effect [21].”
BackgroundSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“More recently, the use of parallel imaging (eg SENSE [35]) with multiple coils, UNFOLD [36] have opened new possibilities to accelerate image acquisition.”
BackgroundSpatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 4,028
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
2011 International Conference on Computer Vision
(2011) · doi:10.1109/iccv17851.2011 · Cited by 2,860
IEEE Transactions on Information Theory
(2023) · IEEE Transactions on Information Theory · doi:10.1109/tit.18 · Cited by 1,856
Cited by
A review of responsive MRI contrast agents: 2005–2014
Hingorani, D. V., Bernstein, A. S., & Pagel, M. D. (2015) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1629 · Cited by 199
Ultrasound triggered, image guided, local drug delivery
Deckers, R., & Moonen, C. T. W. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.07.117 · Cited by 190
Self-citationLocalised drug release using MRI-controlled focused ultrasound hyperthermia
Staruch, R., Chopra, R., & Hynynen, K. (2011) · International Journal of Hyperthermia · doi:10.3109/02656736.2010.518198 · Cited by 159
“Since then it has been shown that spatial temperature distributions can be non-invasively monitored in most tissues using MRI thermometry based on the proton resonance frequency shift [29, 30].”
BackgroundVan Someren, E. J. W. (2007) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00557.2006 · Cited by 89
Imaging of Interventional Therapies in Oncology: Image Guidance, Robotics, and Fusion Systems
Cornelis, F. H., Dzaye, O., Schoellnast, H., & Solomon, S. B. (2023) · Interventional Oncology · doi:10.1007/978-3-030-51192-0_19-1 · Cited by 1
Metadata
- Authors
- Denis de Senneville, B., Quesson, B., & Moonen, C. T. W.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2005-09-01
- Volume
- 21
- Issue
- 6
- Pages
- 515-531
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2005692203
- Cited by
- 175
- References
- 36
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.