EFFECT OF LOADING WITH AIM OIL AEROSOL ON THE COLLECTION EFFICIENCY OF AN ELECTRET FILTER
The DOI matches its Crossref record.
Abstract
Loading of an electret filter changes the distribution of electrical field in the filter from its preloading condition, and, therefore, affects the filtration efficiency of the filter. Liquid droplets collected on electret filters cause degradation of the electrostatic enhancement of filtration efficiency because of charge neutralization and the formation of a dielectric coating over die charged fibers. In this study, calculations were made for the penetration of aerosol particles through a spun-type electret filter as a function of the particulate loading. An assumption was made that each charge collected neutralized one charge of opposite polarity on the fibers of the filter. It was also assumed that the electrostatic charges present on the particles followed the Boltzmann equilibrium charge distribution. The decrease in fiber charge and resulting increase in penetration were calculated as a function of time and of total particulate loading on the filter. The calculated penetrations were compared with experimental measurements of loading on a spun fiber electret filter challenged with monodisperse liquid droplets of bis-Ethylhexyl Sebacate with equilibrium charge distribution and with zero charge. The rate at which the penetration increased was found to be the same for particles with zero charge as for particles with equilibrium charge distribution. For 1 um diameter droplets with equilibrium charge the theory predicted complete discharge of the filter at a loading of around 200 g/m2. Experimentally, only about 0.3 g/m2 was required. This difference indicates the presence of additional mechanisms for the discharge of the fibers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrostatic forces in fibrous filters—a review
Wang, C.-S. (2001) · Powder Technology · doi:10.1016/s0032-5910(01)00307-2 · Cited by 236
Penetration of 4.5nm to aerosol particles through fibrous filters
Huang, S.-H., Chen, C.-W., Chang, C.-P., Lai, C.-Y., & Chen, C.-C. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.05.007 · Cited by 108
Performance Evaluation of Full Facepiece Respirators with Cartridges
Lee, S.-A., Chen, Y.-L., Hwang, D.-C., Wu, C.-C., & Chen, J.-K. (2017) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.11.0485 · Cited by 8
“DOP aerosols have been proved to reduce electric charges on electrostatic filters due to charge neutralization (Biermann et al. , 1982) or ionic conduction through an oil film on the filter fibers (Tennal et al. , 1991).”
Metadata
- Authors
- TENNAL, K. B., MAZUMDER, M. K., SIAG, A., & REDDY, R. N.
- Venue
- Particulate Science and Technology
- Publisher
- Informa UK Limited
- Published
- 1991-01
- Volume
- 9
- Issue
- 1-2
- Pages
- 19-29
- ISSN
- 0272-6351 (ISSN-L)
- 1548-0046
- OpenAlex
- W2011386090
- Cited by
- 34
- References
- 0
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EFFECT OF LOADING WITH AIM OIL AEROSOL ON THE COLLECTION EFFICIENCY OF AN ELECTRET FILTER. https://app.cochat.ai/papers/10.1080/02726359108906574
- The paper
- TENNAL, K. B., MAZUMDER, M. K., SIAG, A., & REDDY, R. N. (1991). EFFECT OF LOADING WITH AIM OIL AEROSOL ON THE COLLECTION EFFICIENCY OF AN ELECTRET FILTER. Particulate Science and Technology. https://doi.org/10.1080/02726359108906574
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.