Differences in Detected Fluorescence Among Several Bacterial Species Measured with a Direct-Reading Particle Sizer and Fluorescence Detector
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Naturally-contained fluorescing chemicals (such as riboflavin or NADPH) can be used to detect the presence of biological organisms. A new instrument from TSI Incorporated measures fluorescence of particles using an ultraviolet laser operating at an excitation wavelength of 355 nm. We have employed this instrument (Model 3312 Ultraviolet Aerodynamic Particle Sizer (tm) Spectrometer) to assess the degree of fluoresence associated with a variety of biological aerosols. Nonfluorescent and fluorescent latex sphere and sodium chloride aerosols were first used to assure proper operation of the instrument and to obtain correct instrument settings. Biological aerosols were then generated by combining organisms with double distilled and filtered water in a Collison nebulizer operated at low pressure. After passage through a charge neutralizer and dilution with humidified air (45%RH), the aerosol was measured downstream for both particle size and fluorescence distributions. Bacterial aerosols generated include Bacillus subtilis subsp. niger (spores and vegetative cells), Staphylococcus epidermidis, Eschericia coli, and Mycobacterium abscessus (a surrogate for M. tuberculosis). Cladosporium spp. fungal spores were also evaluated, and the effect of heat treatment on fluorescence was tested using B. subtilis spores. For each test the percentage of organisms that produced a fluorescence signal above a threshold was recorded. The organisms demonstrated considerable differences in percent fluorescence, ranging from means of 11% for S. epidermidis to 44% for B. subtilis spores. Vegetative cells of B. subtilis were generally less fluorescent (mean of 33%) than the spores, while the highest level of fluorescence was associated with heat-treated spores (averaging about 75%). This instrument has some potential for use in settings where immediate detection of biological organisms is important. Work remains to be done on understanding the effect on fluorescence of organism viability, presence of nonbiological particles, and interferences from mixtures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hairston, P. P., Ho, J., & Quant, F. R. (1997) · Journal of Aerosol Science · doi:10.1016/s0021-8502(96)00448-x · Cited by 231 · cited 3×
“( )Previous studies by Hairston et al. 1997 have shown that nonbiological aerosols can be distinguished from biological aerosols through the use of a prototype instrument equipped with a 325 nm ultraviolet laser (Model 3312 Ultraviolet Aerodynamic Par)ticle Sizer, UV-APS; TSI, Shoreview, MN .”
MethodInfluentialSelf-citationMCCULLOUGH, N., BROSSEAU, L., & VESLEY, D. (1997) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(97)00022-7 · Cited by 75
Self-citation
Cited by
Primary biological aerosol particles in the atmosphere: a review
Després, V. R., Huffman, J. A., Burrows, S. M., Hoose, C., Safatov, A. S., Buryak, G., Fröhlich-Nowoisky, J., Elbert, W., Andreae, M. O., Pöschl, U., et al. (2012) · Tellus B: Chemical and Physical Meteorology · doi:10.3402/tellusb.v64i0.15598 · Cited by 1,500
“The Ultraviolet Aerodynamic Particle Sizer5 (UV-APS) was the first commercially available, fluorescence-based instrument for real-time analysis of biological aerosols (Hairston et al., 1997; Brosseau et al., 2000).”
BackgroundBioaerosols in the Earth system: Climate, health, and ecosystem interactions
Fröhlich-Nowoisky, J., Kampf, C. J., Weber, B., Huffman, J. A., Pöhlker, C., Andreae, M. O., Lang-Yona, N., Burrows, S. M., Gunthe, S. S., Elbert, W., et al. (2016) · Atmospheric Research · doi:10.1016/j.atmosres.2016.07.018 · Cited by 1,007
Autofluorescence of atmospheric bioaerosols – fluorescent biomolecules and potential interferences
Pöhlker, C., Huffman, J. A., & Pöschl, U. (2012) · Atmospheric Measurement Techniques · doi:10.5194/amt-5-37-2012 · Cited by 394
“…aerodynamic particle sizer (UV-APS), for example, provides aerodynamic particle sizing and fluorescence information via singlewavelength LIF by a pulsed Nd:YAG laser (λex = 355 nm; λem= 420–575 nm) (Hairston et al., 1997; Brosseau et al., 2000) and is sold by TSI, Inc. (Shoreview, MN, USA).”
MethodWasisto, H. S., Prades, J. D., Gülink, J., & Waag, A. (2019) · Applied Physics Reviews · doi:10.1063/1.5096322 · Cited by 309
Real-time sensing of bioaerosols: Review and current perspectives
Huffman, J. A., Perring, A. E., Savage, N. J., Clot, B., Crouzy, B., Tummon, F., Shoshanim, O., Damit, B., Schneider, J., Sivaprakasam, V., et al. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1664724 · Cited by 299
Metadata
- Authors
- Brosseau, L. M., Vesley, D., Rice, N., Goodell, K., Nellis, M., & Hairston, P.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2000-06
- Volume
- 32
- Issue
- 6
- Pages
- 545-558
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2099422448
- Cited by
- 80
- References
- 2
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.