CoChat

Collection of three bacterial aerosols by respirator and surgical mask filters under varying conditions of flow and relative humidity

MCCULLOUGH, N, BROSSEAU, L, VESLEY, D · 1997 · The Annals of Occupational Hygiene

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

A variety of respirator filters and surgical masks were challenged with three aerosolized bacteria: Mycobacterium abscessus (M.a.) (a rod), Staphylococcus epidermidis (S.e.) (a sphere), and Bacillus subtilis (B.s.) (a rod). Tests were conducted at two flow rates (45 and 85 l./min) and two humidity levels (30 and 70%). Aerosols were measured with a total-particle, direct-reading, spectrometer and a viable particle cascade impactor. Measurements up- and downstream of the filter or mask were used in determining aerosol penetration; respirator or surgical mask fit was not evaluated. Bioaerosol penetration measured with two aerosol sampling instruments was found to correlate. Additionally, bioaerosol test parameters were evaluated with respect to their effect on penetration. Increasing flow resulted in increased penetration of all organisms while an increase in relative humidity did not exert a consistent effect on all organisms. Of the respirators approved by the National Institute for Occupational Safety and Health (NIOSH), filter efficiency was as expected with dust/mist respirators having the lowest and HEPA filters the highest efficiency. Surgical masks were the least efficient of all filters tested; these are not certified by NIOSH. Bioaerosol penetration was compared to that of a polystyrene latex sphere (PSL) aerosol. Penetration of the test aerosols was predicted on the basis of particle aerodynamic diameter and was expected to be in this order: PSL > M.a. > S.e. = B.s. T…

Overview

Integrity signals

Registry

Crossref · 10.1016/s0003-4878(97)00022-7

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Cited by

See all 75

Metadata

Authors
MCCULLOUGH, N., BROSSEAU, L., & VESLEY, D.
Affiliations
University of Minnesota (US)
Venue
The Annals of Occupational Hygiene
Publisher
Elsevier BV
Published
1997-12
Volume
41
Issue
6
Pages
677-690
ISSN
0003-4878 (ISSN-L)
OpenAlex
W2166295371
Cited by
75
References
17
Citations by year
2026: 1 · 2025: 1 · 2024: 6 · 2023: 6 · 2022: 8 · 2021: 4 · 2020: 5 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 4 · 2015: 1 · 2014: 2 · 2013: 6 · 2012: 1
FWCI
0.73
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • The Annals of Occupational Hygiene (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
Keywords
bacterial aerosols, respirator filters, surgical masks, aerosol penetration, Mycobacterium abscessus, Staphylococcus epidermidis, Bacillus subtilis, relative humidity, filter flow rate, HEPA filters, non-spherical particles
MeSH terms
Aerosols, Analysis of Variance, Bacterial Infections, Humans, Occupational Diseases, Regression Analysis, Respiratory Protective Devices, Bacterial Physiological Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Collection of three bacterial aerosols by respirator and surgical mask filters under varying conditions of flow and relative humidity. https://app.cochat.ai/papers/10.1016/s0003-4878(97)00022-7
The paper
MCCULLOUGH, N., BROSSEAU, L., & VESLEY, D. (1997). Collection of three bacterial aerosols by respirator and surgical mask filters under varying conditions of flow and relative humidity. The Annals of Occupational Hygiene. https://doi.org/10.1016/s0003-4878(97)00022-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.