Positive and Negative Artifacts in Particulate Organic Carbon Measurements with Denuded and Undenuded Sampler Configurations Special Issue of Aerosol Science and Technology on Findings from the Fine Particulate Matter Supersites Program
Open accessThe DOI matches its Crossref record.
Abstract
Measurement of ambient particulate organic carbon (POC) with quartz filters is prone to positive and negative sampling artifacts. One approach for estimating these artifacts is to sample with a backup quartz filter placed behind either the main quartz filter or a Teflon filter in a parallel line. Another approach is to use a denuder to reduce the positive artifact in combination with a highly adsorbent backup filter to capture any negative artifact. Results obtained using both of these approaches in parallel for over one year in Pittsburgh, PA are presented in this article. A sampler using an activated carbon monolith denuder has been developed and tested extensively. Transmission losses were found to be negligible, and the denuder is on average 94% efficient at removing gas-phase organics. Denuder breakthrough is corrected for each run using a dynamic blank in parallel with the sample line. Comparisons with the dynamic blank indicate that the denuder almost eliminates the positive artifact on the quartz filter. Negative artifact from the denuded quartz filter is quantified using a carbon-impregnated glass fiber (CIG) backup filter and was found to be small, typically less than 10% of the ambient POC. Compared to the denuded sampler POC, 24 h bare quartz samples showed an almost constant positive artifact of 0.5 μg-C/m3 for samples taken throughout the year-long study period. Sampling for shorter durations (4–6 h) resulted in a larger positive artifact. A quartz filter behind a Teflon filter (QBT) provides a consistent estimate of the positive artifact on the bare quartz filter irrespective of sample duration, though it overcorrects for the positive artifact by 16–20% (attributed to particulate matter volatilizing off the upstream Teflon filter). The quartz behind quartz (QBQ) approach provides a reasonable estimate of the positive artifact on the bare quartz filter for the 24 h samples but not for the shorter samples. A slight seasonal variation is observed in the absolute value of the positive artifact, with higher values observed during the summer months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The formation, properties and impact of secondary organic aerosol: current and emerging issues
Hallquist, M., Wenger, J. C., Baltensperger, U., Rudich, Y., Simpson, D., Claeys, M., Dommen, J., Donahue, N. M., George, C., Goldstein, A. H., et al. (2009) · Atmospheric Chemistry and Physics · doi:10.5194/acp-9-5155-2009 · Cited by 4,031
Coupled Partitioning, Dilution, and Chemical Aging of Semivolatile Organics
Donahue, N. M., Robinson, A. L., Stanier, C. O., & Pandis, S. N. (2006) · Environmental Science & Technology · doi:10.1021/es052297c · Cited by 1,525
Self-citationThe Molecular Identification of Organic Compounds in the Atmosphere: State of the Art and Challenges
Nozière, B., Kalberer, M., Claeys, M., Allan, J., D’Anna, B., Decesari, S., Finessi, E., Glasius, M., Grgić, I., Hamilton, J. F., et al. (2015) · Chemical Reviews · doi:10.1021/cr5003485 · Cited by 656
Grieshop, A. P., Logue, J. M., Donahue, N. M., & Robinson, A. L. (2009) · Atmospheric Chemistry and Physics · doi:10.5194/acp-9-1263-2009 · Cited by 417
Self-citationAtmospheric organic particulate matter: From smoke to secondary organic aerosol
Donahue, N. M., Robinson, A. L., & Pandis, S. N. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.055 · Cited by 413
Self-citationMass reconstruction methods for PM2.5: a review
Chow, J. C., Lowenthal, D. H., Chen, L.-W. A., Wang, X., & Watson, J. G. (2015) · Air Quality, Atmosphere & Health · doi:10.1007/s11869-015-0338-3 · Cited by 379
“…tandem quartz-fiber filter packs (i.e., OC on quartz-fiber front filter as OCQF, followed by a quartz-fiber backup filter as OCQBQ) to estimate adsorption of volatile organic compounds (VOCs; Chow et al. 2006a; Subramanian et al. 2004; Turpin et al. 1994), but large variations were found in OCQBQ.”
BackgroundZhang, Q., Canagaratna, M. R., Jayne, J. T., Worsnop, D. R., & Jimenez, J. (2005) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2004jd004649 · Cited by 331
Lipsky, E. M., & Robinson, A. L. (2006) · Environmental Science & Technology · doi:10.1021/es050319p · Cited by 301
Self-citationU.S. National PM2.5Chemical Speciation Monitoring Networks—CSN and IMPROVE: Description of networks
Solomon, P. A., Crumpler, D., Flanagan, J. B., Jayanty, R. K. M., Rickman, E. E., & McDade, C. E. (2014) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2014.956904 · Cited by 285
Han, Y. M., Cao, J. J., Lee, S. C., Ho, K. F., & An, Z. S. (2010) · Atmospheric Chemistry and Physics · doi:10.5194/acp-10-595-2010 · Cited by 265
Geller, M. D., Ntziachristos, L., Mamakos, A., Samaras, Z., Schmitz, D. A., Froines, J. R., & Sioutas, C. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.018 · Cited by 223
“In a previous study in Pittsburgh (Subramanian et al., 2004), an average positive OC artifact of 0.48 (70.15) mg of C per cm2 of quartz filter area was reported, whereas Arhami et al. (2006) reported similar artifact values in the quartz substrates of the Sunset Labs EC-OC monitor, with an average adsorption artifact…”
ResultInfluentialLopez-Hilfiker, F. D., Pospisilova, V., Huang, W., Kalberer, M., Mohr, C., Stefenelli, G., Thornton, J. A., Baltensperger, U., Prevot, A. S. H., & Slowik, J. G. (2019) · Atmospheric Measurement Techniques · doi:10.5194/amt-12-4867-2019 · Cited by 213
“…which is insufficient for many atmospheric processes, and the potential for chemical changes due to evaporation, adsorption, and/or reaction during sample collection, transfer, and/or storage (Turpin et al., 1994; Subramanian et al., 2004; Timkovsky et al., 2015; Kristensen et al., 2016).”
BackgroundYttri, K. E., Aas, W., Bjerke, A., Cape, J. N., Cavalli, F., Ceburnis, D., Dye, C., Emblico, L., Facchini, M. C., Forster, C., et al. (2007) · Atmospheric Chemistry and Physics · doi:10.5194/acp-7-5711-2007 · Cited by 195
Indoor–outdoor relationships of particle number and mass in four European cities
Hoek, G., Kos, G., Harrison, R., de Hartog, J., Meliefste, K., ten Brink, H., Katsouyanni, K., Karakatsani, A., Lianou, M., & Kotronarou, A. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.09.026 · Cited by 180
Mazzoleni, L. R., Zielinska, B., & Moosmüller, H. (2007) · Environmental Science & Technology · doi:10.1021/es061702c · Cited by 177
Cabada, J. C., Rees, S., Takahama, S., Khlystov, A., Pandis, S. N., Davidson, C. I., & Robinson, A. L. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.03.004 · Cited by 170
“For the winter, the concentrations measured by the undenuded sampler were corrected for positive artifact by subtracting the measured organic concentration in the backup filter (Subramanian et al., 2004).”
MethodSelf-citationChow, J. C., Chen, L. ‐. A., Watson, J. G., Lowenthal, D. H., Magliano, K. A., Turkiewicz, K., & Lehrman, D. E. (2006) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2005jd006457 · Cited by 160
“In these cases, the positive VOC artifact appeared to dominate, which is consistent with other recent studies [e.g., Subramanian et al., 2004; Chow et al., 2006b].”
Result
Metadata
- Authors
- Subramanian, R., Khlystov, A. Y., Cabada, J. C., & Robinson, A. L.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2004-12
- Volume
- 38
- Issue
- sup1
- Pages
- 27-48
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2065110306
- Cited by
- 252
- References
- 0
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.