Equations Governing Single and Tandem DMA Configurations and a New Lognormal Approximation to the Transfer Function
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The basic equations governing the responses of single and tandem differential mobility analyzer (DMA) systems are summarized. Particle diffusion within the DMA resulting in broadening of the transfer function is included in this analysis. For tandem DMA (TDMA) work, a given particle diameter exiting the first DMA is modeled in the following conditioner as growing into a multi-modal lognormal distribution before entering the second DMA. Approximations and solution techniques for both single and tandem DMA systems are discussed. A new lognormal approximation to the DMA transfer function is introduced leading to a simple lognormal form for the TDMA response function. The maximum absolute error of the transfer function is 0.10 at 200 nm in the range plus or minus one and a half standard deviations of the lognormal fit. It is 0.035 at 3 nm in the range plus or minus two standard deviations of the lognormal fit. The maximum fractional error in the calculated TDMA response is no more than 0.08 at 200 nm and 3 nm in the range plus or minus one standard deviation of the lognormal fit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerosol classification by electric mobility: apparatus, theory, and applications
Knutson, E. O., & Whitby, K. T. (1975) · Journal of Aerosol Science · doi:10.1016/0021-8502(75)90060-9 · Cited by 1,395
Scanning Electrical Mobility Spectrometer
Wang, S. C., & Flagan, R. C. (1990) · Aerosol Science and Technology · doi:10.1080/02786829008959441 · Cited by 969
Application of the tandem differential mobility analyzer to studies of droplet growth or evaporation
Rader, D. J., & McMurry, P. H. (1986) · Journal of Aerosol Science · doi:10.1016/0021-8502(86)90031-5 · Cited by 496
Self-citationOn-line measurements of diesel nanoparticle composition and volatility
Sakurai, H., Tobias, H. J., Park, K., Zarling, D., Docherty, K. S., Kittelson, D. B., McMurry, P. H., & Ziemann, P. J. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)01017-8 · Cited by 365
Self-citationSakurai, H., Park, K., McMurry, P. H., Zarling, D. D., Kittelson, D. B., & Ziemann, P. J. (2003) · Environmental Science & Technology · doi:10.1021/es034362t · Cited by 176
Self-citationRadial Differential Mobility Analyzer
Zhang, S.-H., Akutsu, Y., Russell, L. M., Flagan, R. C., & Seinfeld, J. H. (1995) · Aerosol Science and Technology · doi:10.1080/02786829508965320 · Cited by 162
Philippin, S., Wiedensohler, A., & Stratmann, F. (2003) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2003.07.004 · Cited by 122
Kühn, T., Biswas, S., & Sioutas, C. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.08.025 · Cited by 66
Cited by
Wiedensohler, A., Birmili, W., Nowak, A., Sonntag, A., Weinhold, K., Merkel, M., Wehner, B., Tuch, T., Pfeifer, S., Fiebig, M., et al. (2012) · Atmospheric Measurement Techniques · doi:10.5194/amt-5-657-2012 · Cited by 868
Self-citationWang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1100710 · Cited by 471
Lapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Iida, K., Stolzenburg, M. R., & McMurry, P. H. (2009) · Aerosol Science and Technology · doi:10.1080/02786820802488194 · Cited by 201
“The procedure accounts for the effect of the diffusional broadening in the width of DMA transfer function ( Stolzenburg 1988 ; Stolzenburg and McMurry 2008 ), and the method is relatively straightforward and also yields reasonably accurate results.”
MethodSelf-citationMobility particle size spectrometers: Calibration procedures and measurement uncertainties
Wiedensohler, A., Wiesner, A., Weinhold, K., Birmili, W., Hermann, M., Merkel, M., Müller, T., Pfeifer, S., Schmidt, A., Tuch, T., et al. (2018) · Aerosol Science and Technology · doi:10.1080/02786826.2017.1387229 · Cited by 190
“A DMA (see, e.g., Knutson and Whitby 1975; Liu and Pui 1974; Flagan 1999; Stolzenburg and McMurry 2008) is usually designed as a cylindrical capacitor in which charged aerosol is injected through an annular slit close to the outer electrode and merged with the particle-free and dried sheath air fl…”
Metadata
- Authors
- Stolzenburg, M. R., & McMurry, P. H.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2008-04-24
- Volume
- 42
- Issue
- 6
- Pages
- 421-432
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2009088892
- Cited by
- 259
- References
- 8
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.