Laboratory Evaluation and Calibration of Three Low-Cost Particle Sensors for Particulate Matter Measurement
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Particle sensors offer significant advantages of compact size and low cost, and have recently drawn great attention for usage as portable monitors measuring particulate matter mass concentrations. However, most sensor systems have not been thoroughly evaluated with standardized calibration protocols, and their data quality is not well documented. In this work, three low-cost particle sensors based on light scattering (Shinyei PPD42NS, Samyoung DSM501A, and Sharp GP2Y1010AU0F) were evaluated by calibration methods adapted from the US EPA 2013 Air Sensor Workshop recommendations. With a SidePak (TSI Inc., St. Paul, MN, USA), a scanning mobility particle sizer (TSI Inc.), and an AirAssure™ PM2.5 Indoor Air Quality Monitor (TSI Inc.), which itself relies on a GP2Y1010AU0F sensor as reference instruments, six performance aspects were examined: linearity of response, precision of measurement, limit of detection, dependence on particle composition, dependence on particle size, and relative humidity and temperature influences. This work found that: (a) all three sensors demonstrated high linearity against SidePak measured concentrations, with R2 values higher than 0.8914 in the particle concentration range of 0–1000 μg/m3, and the linearity depended on the studied range of particle concentrations; (b) the standard deviations of the sensors varied from 15 to 90 μg/m3 for a concentration range of 0–1000 μg/m3; (c) the outputs of all three sensors depended highly on particle composition and size, resulting in as high as 10 times difference in the sensor outputs; and (d) humidity affected the sensor response. This article provides further recommendations for applications of the three tested sensors.Copyright 2015 American Association for Aerosol Research
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731
Atmospheric chemistry and physics: from air pollution to climate change
(1998) · Choice Reviews Online · doi:10.5860/choice.35-5721 · Cited by 4,944
High secondary aerosol contribution to particulate pollution during haze events in China
Huang, R.-J., Zhang, Y., Bozzetti, C., Ho, K.-F., Cao, J.-J., Han, Y., Daellenbach, K. R., Slowik, J. G., Platt, S. M., Canonaco, F., et al. (2014) · Nature · doi:10.1038/nature13774 · Cited by 4,556
Evolution of Organic Aerosols in the Atmosphere
Jimenez, J. L., Canagaratna, M. R., Donahue, N. M., Prevot, A. S. H., Zhang, Q., Kroll, J. H., DeCarlo, P. F., Allan, J. D., Coe, H., Ng, N. L., et al. (2009) · Science · doi:10.1126/science.1180353 · Cited by 4,167 · cited 3×
“In this study, NH4NO3 was used to simulate the measurement of atmospheric particles in heavily polluted areas, since a large proportion of the inorganic contents of atmospheric particles is attributed to the reaction between NH3 and HNO3 (Jimenez et al. 2009; Guo et al. 2014; Seinfeld and Pandis 2012).”
MethodSelf-citationSensor networks: Evolution, opportunities, and challenges
Chong, C.-Y., & Kumar, S. P. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.814918 · Cited by 3,079
Schubert, E. F., Cho, J., & Kim, J. K. (2015) · Kirk-Othmer Encyclopedia of Chemical Technology · doi:10.1002/0471238961.1209070811091908.a01.pub3 · Cited by 2,012
Elucidating severe urban haze formation in China
Guo, S., Hu, M., Zamora, M. L., Peng, J., Shang, D., Zheng, J., Du, Z., Wu, Z., Shao, M., Zeng, L., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1419604111 · Cited by 1,711
Aerosol Technology : Properties, Behavior, and Measurement of Airborne Particles
Hinds, W. C. (1982) · Cited by 1,470
Aerosol classification by electric mobility: apparatus, theory, and applications
Knutson, E. O., & Whitby, K. T. (1975) · Journal of Aerosol Science · doi:10.1016/0021-8502(75)90060-9 · Cited by 1,395
Light-Emitting Diodes by E. Fred Schubert
Schubert, E. F. (2006) · Cited by 1,293
Schubert, E. F., Gessmann, T., & Kim, J. K. (2005) · Kirk-Othmer Encyclopedia of Chemical Technology · doi:10.1002/0471238961.1209070811091908.a01.pub2 · Cited by 1,244
Light-Emitting Diodes by E. Fred Schubert
Schubert, E. F. (2006) · Cited by 1,171
Scanning Electrical Mobility Spectrometer
Wang, S. C., & Flagan, R. C. (1990) · Aerosol Science and Technology · doi:10.1080/02786829008959441 · Cited by 969
Size-dependent toxicity of metal oxide particles—A comparison between nano- and micrometer size
Karlsson, H. L., Gustafsson, J., Cronholm, P., & Möller, L. (2009) · Toxicology Letters · doi:10.1016/j.toxlet.2009.03.014 · Cited by 949 · cited 2×
“Particulate matter (PM) is an important parameter in determining air quality, affecting visibility (Guo et al. 2014), human health (Biswas and Wu 2005; Karlsson et al. 2009), and global climate (Stocker et al. 2013).”
BackgroundNanoparticles and the Environment
Biswas, P., & Wu, C.-Y. (2005) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2005.10464656 · Cited by 793
Self-citationAnalysis of a winter regional haze event and its formation mechanism in the North China Plain
Zhao, X. J., Zhao, P. S., Xu, J., Meng, Pu, W. W., Dong, F., He, D., & Shi, Q. F. (2013) · Atmospheric Chemistry and Physics · doi:10.5194/acp-13-5685-2013 · Cited by 611
Tiwari, S., Srivastava, A. K., Bisht, D. S., Parmita, P., Srivastava, M. K., & Attri, S. D. (2013) · Atmospheric Research · doi:10.1016/j.atmosres.2013.01.011 · Cited by 367
Bewertung und Vergleich von Analysenverfahren
Kaiser, H., & Specker, H. (1956) · Fresenius' Zeitschrift für analytische Chemie · doi:10.1007/bf00454145 · Cited by 356
Gao, M., Cao, J., & Seto, E. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.01.013 · Cited by 345
Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California
Holstius, D. M., Pillarisetti, A., Smith, K. R., & Seto, E. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-1121-2014 · Cited by 312
Stolzenburg, M. R., & McMurry, P. H. (2008) · Aerosol Science and Technology · doi:10.1080/02786820802157823 · Cited by 259
Evolution of PM2.5 Measurements and Standards in the U.S. and Future Perspectives for China
Cao, J., Chow, J. C., Lee, S., & Watson, J. G. (2013) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.11.0302 · Cited by 141
Incense Smoke: Characterization and Dynamics in Indoor Environments
Cheng, Y. S., Bechtold, W. E., Yu, C. C., & Hung, I. (1995) · Aerosol Science and Technology · doi:10.1080/02786829508965312 · Cited by 115
Protocol of evaluation and calibration of low-cost gas sensors for the monitoring of air pollution
Spinelle, L., Aleixandre, M., & Gerboles, M. (2013) · Joint Research Centre (European Commission) · doi:10.2788/9916 · Cited by 107
An inexpensive light-scattering particle monitor: field validation
Chowdhury, Z., Edwards, R. D., Johnson, M., Naumoff Shields, K., Allen, T., Canuz, E., & Smith, K. R. (2007) · Journal of Environmental Monitoring · doi:10.1039/b709329m · Cited by 72
An Inexpensive Dual-Chamber Particle Monitor: Laboratory Characterization
Edwards, R. D., Smith, K. R., Kirby, B., Allen, T., Litton, C. D., & Hering, S. V. (2006) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2006.10464491 · Cited by 61
Sahu, M., Peipert, J. D., Singhal, V., Yadama, G. N., & Biswas, P. (2011) · Environmental Science & Technology · doi:10.1021/es1029415 · Cited by 57
Self-citationLitton, C. D., Smith, K. R., Edwards, R. D., & Allen, T. (2004) · Aerosol Science and Technology · doi:10.1080/027868290883333 · Cited by 54
Cited by
Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., et al. (2018) · Environment International · doi:10.1016/j.envint.2018.04.018 · Cited by 864
Aerosol Health Effects from Molecular to Global Scales
Shiraiwa, M., Ueda, K., Pozzer, A., Lammel, G., Kampf, C. J., Fushimi, A., Enami, S., Arangio, A. M., Fröhlich-Nowoisky, J., Fujitani, Y., et al. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b04417 · Cited by 673
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Ambient and laboratory evaluation of a low-cost particulate matter sensor
Kelly, K. E., Whitaker, J., Petty, A., Widmer, C., Dybwad, A., Sleeth, D., Martin, R., & Butterfield, A. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2016.12.039 · Cited by 498
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Metadata
- Authors
- Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2015-10-19
- Volume
- 49
- Issue
- 11
- Pages
- 1063-1077
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2177101396
- Cited by
- 471
- References
- 28
- FWCI
- 16.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.