Laboratory Evaluation and Calibration of Three Low-Cost Particle Sensors for Particulate Matter Measurement
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Particle sensors offer significant advantages of compact size and low cost, and have recently drawn great attention for usage as portable monitors measuring particulate matter mass concentrations. However, most sensor systems have not been thoroughly evaluated with standardized calibration protocols, and their data quality is not well documented. In this work, three low-cost particle sensors based on light scattering (Shinyei PPD42NS, Samyoung DSM501A, and Sharp GP2Y1010AU0F) were evaluated by calibration methods adapted from the US EPA 2013 Air Sensor Workshop recommendations. With a SidePak (TSI Inc., St. Paul, MN, USA), a scanning mobility particle sizer (TSI Inc.), and an AirAssure™ PM2.5 Indoor Air Quality Monitor (TSI Inc.), which itself relies on a GP2Y1010AU0F sensor as reference instruments, six performance aspects were examined: linearity of response, precision of measurement, limit of detection, dependence on particle composition, dependence on particle size, and relative humidity and temperature influences. This work found that: (a) all three sensors demonstrated high linearity against SidePak measured concentrations, with R2 values higher than 0.8914 in the particle concentration range of 0–1000 μg/m3, and the linearity depended on the studied range of particle concentrations; (b) the standard deviations of the sensors varied from 15 to 90 μg/m3 for a concentration range of 0–1000 μg/m3; (c) the outputs of all three sensors depended highly on particle composition and size, resulting in as high as 10 times difference in the sensor outputs; and (d) humidity affected the sensor response. This article provides further recommendations for applications of the three tested sensors.Copyright 2015 American Association for Aerosol Research
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731
Atmospheric chemistry and physics: from air pollution to climate change
(1998) · Choice Reviews Online · doi:10.5860/choice.35-5721 · Cited by 4,944
High secondary aerosol contribution to particulate pollution during haze events in China
Huang, R.-J., Zhang, Y., Bozzetti, C., Ho, K.-F., Cao, J.-J., Han, Y., Daellenbach, K. R., Slowik, J. G., Platt, S. M., Canonaco, F., et al. (2014) · Nature · doi:10.1038/nature13774 · Cited by 4,556
Evolution of Organic Aerosols in the Atmosphere
Jimenez, J. L., Canagaratna, M. R., Donahue, N. M., Prevot, A. S. H., Zhang, Q., Kroll, J. H., DeCarlo, P. F., Allan, J. D., Coe, H., Ng, N. L., et al. (2009) · Science · doi:10.1126/science.1180353 · Cited by 4,167 · cited 3×
“In this study, NH4NO3 was used to simulate the measurement of atmospheric particles in heavily polluted areas, since a large proportion of the inorganic contents of atmospheric particles is attributed to the reaction between NH3 and HNO3 (Jimenez et al. 2009; Guo et al. 2014; Seinfeld and Pandis 2012).”
MethodSelf-citationSensor networks: Evolution, opportunities, and challenges
Chong, C.-Y., & Kumar, S. P. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.814918 · Cited by 3,079
Schubert, E. F., Cho, J., & Kim, J. K. (2015) · Kirk-Othmer Encyclopedia of Chemical Technology · doi:10.1002/0471238961.1209070811091908.a01.pub3 · Cited by 2,012
Elucidating severe urban haze formation in China
Guo, S., Hu, M., Zamora, M. L., Peng, J., Shang, D., Zheng, J., Du, Z., Wu, Z., Shao, M., Zeng, L., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1419604111 · Cited by 1,711
Aerosol Technology : Properties, Behavior, and Measurement of Airborne Particles
Hinds, W. C. (1982) · Cited by 1,470
Aerosol classification by electric mobility: apparatus, theory, and applications
Knutson, E. O., & Whitby, K. T. (1975) · Journal of Aerosol Science · doi:10.1016/0021-8502(75)90060-9 · Cited by 1,395
Light-Emitting Diodes by E. Fred Schubert
Schubert, E. F. (2006) · Cited by 1,293
Cited by
Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., et al. (2018) · Environment International · doi:10.1016/j.envint.2018.04.018 · Cited by 864
Aerosol Health Effects from Molecular to Global Scales
Shiraiwa, M., Ueda, K., Pozzer, A., Lammel, G., Kampf, C. J., Fushimi, A., Enami, S., Arangio, A. M., Fröhlich-Nowoisky, J., Fujitani, Y., et al. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b04417 · Cited by 673
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Ambient and laboratory evaluation of a low-cost particulate matter sensor
Kelly, K. E., Whitaker, J., Petty, A., Widmer, C., Dybwad, A., Sleeth, D., Martin, R., & Butterfield, A. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2016.12.039 · Cited by 498
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Field evaluation of low-cost particulate matter sensors in high- and low-concentration environments
Zheng, T., Bergin, M. H., Johnson, K. K., Tripathi, S. N., Shirodkar, S., Landis, M. S., Sutaria, R., & Carlson, D. E. (2018) · Atmospheric Measurement Techniques · doi:10.5194/amt-11-4823-2018 · Cited by 418
Malings, C., Tanzer, R., Hauryliuk, A., Saha, P. K., Robinson, A. L., Presto, A. A., & Subramanian, R. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1623863 · Cited by 343
3D-printed sensors: Current progress and future challenges
Khosravani, M. R., & Reinicke, T. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.111916 · Cited by 331
Low-Cost Outdoor Air Quality Monitoring and Sensor Calibration: A Survey and Critical Analysis
Concas, F., Mineraud, J., Lagerspetz, E., Varjonen, S., Liu, X., Puolamäki, K., Nurmi, P., & Tarkoma, S. (2021) · ACM Transactions on Sensor Networks · doi:10.1145/3446005 · Cited by 265
Smart homes and the control of indoor air quality
Schieweck, A., Uhde, E., Salthammer, T., Salthammer, L. C., Morawska, L., Mazaheri, M., & Kumar, P. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.05.057 · Cited by 255
Bulot, F. M. J., Johnston, S. J., Basford, P. J., Easton, N. H. C., Apetroaie-Cristea, M., Foster, G. L., Morris, A. K. R., Cox, S. J., & Loxham, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-43716-3 · Cited by 241
Assessing the accuracy of low-cost optical particle sensors using a physics-based approach
Hagan, D. H., & Kroll, J. H. (2020) · Atmospheric Measurement Techniques · doi:10.5194/amt-13-6343-2020 · Cited by 231
“One of the most widely discussed sources of error for OPS measurements is that caused by water uptake (Crilley et al., 2018; Di Antonio et al., 2018; Malings et al., 2020; Wang et al., 2015; Zheng et al., 2018).”
BackgroundMethodInfluentialLow-cost sensors as an alternative for long-term air quality monitoring
Liu, X., Jayaratne, R., Thai, P., Kuhn, T., Zing, I., Christensen, B., Lamont, R., Dunbabin, M., Zhu, S., Gao, J., et al. (2020) · Environmental Research · doi:10.1016/j.envres.2020.109438 · Cited by 222
Inter-comparison of low-cost sensors for measuring the mass concentration of occupational aerosols
Sousan, S., Koehler, K., Thomas, G., Park, J. H., Hillman, M., Halterman, A., & Peters, T. M. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1162901 · Cited by 220
“Wang et al. (2015) measured the precision of the Sharp GP sensor, and found that the standard deviation among devices increased with mass concentrations, concluding that the Sharp GP sensors have low precision.”
InfluentialA Review of Low-Cost Particulate Matter Sensors from the Developers’ Perspectives
Alfano, B., Barretta, L., Del Giudice, A., De Vito, S., Di Francia, G., Esposito, E., Formisano, F., Massera, E., Miglietta, M. L., & Polichetti, T. (2020) · Sensors · doi:10.3390/s20236819 · Cited by 202
“One of the earliest test chambers was ealized by Yang Wang in 20 [63].”
BackgroundMethodInfluentialMagi, B. I., Cupini, C., Francis, J., Green, M., & Hauser, C. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1619915 · Cited by 192
“5 shows that PA-II is biased high (Figure 2) which is consistent with similar collocation and lab comparisons (Holstius et al. 2014; Kelly et al. 2017; Wang et al. 2015; Zamora et al. 2019).”
ResultStavroulas, I., Grivas, G., Michalopoulos, P., Liakakou, E., Bougiatioti, A., Kalkavouras, P., Fameli, K., Hatzianastassiou, N., Mihalopoulos, N., & Gerasopoulos, E. (2020) · Atmosphere · doi:10.3390/atmos11090926 · Cited by 183
Metadata
- Authors
- Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2015-10-19
- Volume
- 49
- Issue
- 11
- Pages
- 1063-1077
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2177101396
- Cited by
- 471
- References
- 28
- FWCI
- 16.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.