Inter-comparison of low-cost sensors for measuring the mass concentration of occupational aerosols
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Low-cost sensors are effective for measuring the mass concentration of ambient aerosols and second-hand smoke in homes, but their use at concentrations relevant to occupational settings has not been demonstrated. We measured the concentrations of four aerosols (salt, Arizona road dust, welding fume, and diesel exhaust) with three types of low-cost sensors (a DC1700 from Dylos and two commodity sensors from Sharp), an aerosol photometer, and reference instruments at concentrations up to 6500 µg/m3. Raw output was used to assess sensor precision and develop equations to compute mass concentrations. EPA and NIOSH protocols were used to assess the mass concentrations estimated with low-cost sensors compared to reference instruments. The detection efficiency of the DC1700 ranged from 0.04% at 0.1 µm to 108% at 5 µm, as expected, although misclassification of fine and coarse particles was observed. The raw output of the DC1700 had higher precision (lower coefficient of variation, CV = 7.4%) than that of the two sharp devices (CV = 25% and 17%), a finding attributed to differences in manufacturer calibration. Aerosol type strongly influenced sensor response, indicating the need for on-site calibration to convert sensor output to mass concentration. Once calibrated, however, the mass concentration estimated with low-cost sensors was highly correlated with that of reference instruments (R2= 0.99). These results suggest that the DC1700 and Sharp sensors are useful in estimating aerosol mass concentration for aerosols at concentrations relevant to the workplace.© 2016 American Association for Aerosol Research
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731 · cited 1×
“Such exposures include dust, sea salt, automobile exhaust, industrial emissions, welding fumes, sawdust, animal waste, and crop dust (Seinfeld and Pandis 2012).”
An association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018 · cited 1×
“Environmental and occupational exposures to fine particulate matter (particles smaller than 2.5 μm) and coarse particulate matter (particles between 2.5 μm and 10 μm) have been associated with adverse health effects and increased mortality rates (Grant 2009; Dockery et al. 1993).”
InfluentialAtmospheric chemistry and physics: from air pollution to climate change
(1998) · Choice Reviews Online · doi:10.5860/choice.35-5721 · Cited by 4,944
Antonini, J. M. (2003) · Critical Reviews in Toxicology · doi:10.1080/713611032 · Cited by 499 · cited 1×
“Exposure to specific aerosols leads to specific adverse health outcomes: coal mine dust to adverse respiratory changes (Henneberger and Attfield 1997); welding fume to respiratory diseases and lung cancer (Antonini 2003); and diesel fume to pulmonary disease (Hart et al.”
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1100710 · Cited by 471 · cited 6×
“Wang et al. (2015) measured the precision of the Sharp GP sensor, and found that the standard deviation among devices increased with mass concentrations, concluding that the Sharp GP sensors have low precision.”
InfluentialPark, K., Kittelson, D. B., & McMurry, P. H. (2004) · Aerosol Science and Technology · doi:10.1080/027868290505189 · Cited by 358 · cited 2×
“We also assumed a constant density for diesel fume, although Park et al. (2004) report that density decreases with particles larger than 300 nm. Lastly, the difference in MMD between salt aerosols was smaller than anticipated, yielding little information on the effect of size on sensor response.”
Personal exposure monitoring of PM 2.5 in indoor and outdoor microenvironments
Steinle, S., Reis, S., Sabel, C. E., Semple, S., Twigg, M. M., Braban, C. F., Leeson, S. R., Heal, M. R., Harrison, D., Lin, C., et al. (2015) · Science of The Total Environment · doi:10.1016/j.scitotenv.2014.12.003 · Cited by 337 · cited 2×
“Steinle et al. (2015) found that number concentration measured with the DC1700 agreed well with mass concentrations measured with a TEOM (Thermo Fisher Scientific Inc., USA) in urban (R2 = 0.7) and rural areas (R 2 = 0.9).”
InfluentialField calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California
Holstius, D. M., Pillarisetti, A., Smith, K. R., & Seto, E. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-1121-2014 · Cited by 312 · cited 3×
“In an urban setting, Holstius et al. (2014) observed that the [number or mass concentration measured with the DC1700 agreed well (R2 = 0.99) with that measured with an OPC (~ 12,000, GRIMM, Model 1.108, GRIMM Aerosol Technixk GmbH & Co., Ainring, Germany).”
InfluentialOccupational exposure to diesel exhaust and lung cancer: a meta-analysis.
Lipsett, M., & Campleman, S. (1999) · American Journal of Public Health · doi:10.2105/ajph.89.7.1009 · Cited by 231
A low-cost particle counter as a realtime fine-particle mass monitor
Northcross, A., Edwards, R. D., Johnson, M. A., Wang, Z.-M., Zhu, K., Allen, T., & Smith, K. R. (2013) · Environmental Science Processes & Impacts · doi:10.1039/c2em30568b · Cited by 143 · cited 6×
“Northcross et al. (2013) and Wang et al. (2015) both suggest that the refractive index plays a role in response variation for different aerosol types.”
Influential
Cited by
Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., et al. (2018) · Environment International · doi:10.1016/j.envint.2018.04.018 · Cited by 864
Aerosol Health Effects from Molecular to Global Scales
Shiraiwa, M., Ueda, K., Pozzer, A., Lammel, G., Kampf, C. J., Fushimi, A., Enami, S., Arangio, A. M., Fröhlich-Nowoisky, J., Fujitani, Y., et al. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b04417 · Cited by 673
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Toxic Cyanobacteria: A Growing Threat to Water and Air Quality
Plaas, H. E., & Paerl, H. W. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c06653 · Cited by 297
Low-Cost Outdoor Air Quality Monitoring and Sensor Calibration: A Survey and Critical Analysis
Concas, F., Mineraud, J., Lagerspetz, E., Varjonen, S., Liu, X., Puolamäki, K., Nurmi, P., & Tarkoma, S. (2021) · ACM Transactions on Sensor Networks · doi:10.1145/3446005 · Cited by 265
Smart homes and the control of indoor air quality
Schieweck, A., Uhde, E., Salthammer, T., Salthammer, L. C., Morawska, L., Mazaheri, M., & Kumar, P. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.05.057 · Cited by 255
Field and Laboratory Evaluations of the Low-Cost Plantower Particulate Matter Sensor
Levy Zamora, M., Xiong, F., Gentner, D., Kerkez, B., Kohrman-Glaser, J., & Koehler, K. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b05174 · Cited by 244
Self-citationAssessing the accuracy of low-cost optical particle sensors using a physics-based approach
Hagan, D. H., & Kroll, J. H. (2020) · Atmospheric Measurement Techniques · doi:10.5194/amt-13-6343-2020 · Cited by 231
“In practice, nephelometers are empirically calibrated by correlating the total scattered light signal with a reference mass measurement (Dacunto et al., 2015; Sousan et al., 2016b; Wang et al., 2015).”
BackgroundMethodSousan, S., Koehler, K., Hallett, L., & Peters, T. M. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1232859 · Cited by 210
“Then we assumed a known aerosol, 2,200 kg/m 3 for salt, 3,400 kg/m 3 for welding fume, and 2,650 kg/m 3 for ARD (Sousan et al. 2016).”
InfluentialSelf-citationA Review of Low-Cost Particulate Matter Sensors from the Developers’ Perspectives
Alfano, B., Barretta, L., Del Giudice, A., De Vito, S., Di Francia, G., Esposito, E., Formisano, F., Massera, E., Miglietta, M. L., & Polichetti, T. (2020) · Sensors · doi:10.3390/s20236819 · Cited by 202
“concentrations, this concentration condition can considerably reduce the testing time [56,64,65], as this apparatus is equipped with further output airflow to accelerate the PM concentration decay.”
BackgroundResult
Metadata
- Authors
- Sousan, S., Koehler, K., Thomas, G., Park, J. H., Hillman, M., Halterman, A., & Peters, T. M.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2016-03-10
- Volume
- 50
- Issue
- 5
- Pages
- 462-473
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2329466550
- Cited by
- 220
- References
- 15
- FWCI
- 13.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.