Evaluation of the Alphasense optical particle counter (OPC-N2) and the Grimm portable aerosol spectrometer (PAS-1.108)
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
We compared the performance of a low-cost (∼$500), compact optical particle counter (OPC, OPC-N2, Alphasense) to another OPC (PAS-1.108, Grimm Technologies) and reference instruments. We measured the detection efficiency of the OPCs by size from 0.5 to 5 μm for monodispersed, polystyrene latex (PSL) spheres. We then compared number and mass concentrations measured with the OPCs to those measured with reference instruments for three aerosols: salt, welding fume and Arizona road dust. The OPC-N2 detection efficiency for monodispersed was similar to the PAS-1.108 for particles larger than 0.8 μm (minimum of 79% at 1 μm and maximum of 101% at 3 μm). For 0.5-μm particles, the detection efficiency of OPCN2 was underestimated at 78%, whereas PAS-1.108 overestimated concentrations by 183%. The mass concentrations from the OPCs were linear (r ≥ 0.97) with those from the reference instruments for all aerosols, although the slope and intercept were different. The mass concentrations were overestimated for dust (OPC-N2, slope = 1.6; PAS-1.108, slope = 2.7) and underestimated for welding fume (OPC-N2, slope = 0.05; PAS-1.108, slope = 0.4). The coefficient of variation (CV, precision) for OPC-N2 for all experiments was between 4.2% and 16%. These findings suggest that, given site-specific calibrations, the OPC-N2 can provide number and mass concentrations similar to the PAS-1.108 for particles larger than 1 μm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution
Pope III, C. A. (2002) · JAMA · doi:10.1001/jama.287.9.1132 · Cited by 8,447 · cited 2×
“…and PM 10 (Dockery et al. 1993; Landen et al. 2011; Ostro et al. 2015; Zanobetti and Schwartz 2009), lung cancer with PM 2.5 (Harrison et al. 2004; Pope et al. 2002), and cardiopulmonary diseases with PM 1 , PM 2.5 , and PM 10 (Burnett et al. 1999; Franck et al. 2011; Järvelä et al. 2013; Ostro…”
InfluentialAn association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018 · cited 1×
“Increased mortality rates have been associated with PM 2.5 and PM 10 (Dockery et al. 1993; Landen et al. 2011; Ostro et al. 2015; Zanobetti and Schwartz 2009), lung cancer with PM 2.5 (Harrison et al. 2004; Pope et al. 2002), and cardiopulmonary diseases with PM 1 , PM 2.5 , and PM 10 (Burnett et…”
InfluentialAerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367 · cited 4×
“The result is called a lognormal distribution that helps correct the distorted skewness exhibited over the large particle range caused by the normal distribution (Hinds 1999).”
InfluentialIs Daily Mortality Associated Specifically with Fine Particles?
Schwartz, J., Dockery, D. W., & Neas, L. M. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467528 · Cited by 1,561 · cited 1×
“Environmental studies show that PM 2.5 from combustion sources are more strongly associated with mortality (Schwartz et al. 1996) and adverse respiratory health effects (Schwartz and Neas 2000) than coarse particles (PM 10-2.5 ).”
InfluentialAerosol classification by electric mobility: apparatus, theory, and applications
Knutson, E. O., & Whitby, K. T. (1975) · Journal of Aerosol Science · doi:10.1016/0021-8502(75)90060-9 · Cited by 1,395 · cited 2×
“A scanning mobility particle sizer (SMPS; cost: $60,000C) is used to measure number concentration for submicron particles at different particle sizes (Knutson and Whitby 1975).”
Scanning Electrical Mobility Spectrometer
Wang, S. C., & Flagan, R. C. (1990) · Aerosol Science and Technology · doi:10.1080/02786829008959441 · Cited by 969 · cited 2×
“One reason is that the instruments use different principles; the SMPS uses the electrical mobility (Wang and Flagan 1990) and the APS uses time-of-flight between two narrow laser beams (Armendariz and Leith 2002).”
InfluentialThe Effect of Fine and Coarse Particulate Air Pollution on Mortality: A National Analysis
Zanobetti, A., & Schwartz, J. (2009) · Environmental Health Perspectives · doi:10.1289/ehp.0800108 · Cited by 643 · cited 1×
“Increased mortality rates have been associated with PM 2.5 and PM 10 (Dockery et al. 1993; Landen et al. 2011; Ostro et al. 2015; Zanobetti and Schwartz 2009), lung cancer with PM 2.5 (Harrison et al. 2004; Pope et al. 2002), and cardiopulmonary diseases with PM 1 , PM 2.5 , and PM 10 (Burnett et…”
InfluentialPrinciples, Methods and Application of Particle Size Analysis
(1991) · Cambridge University Press eBooks · doi:10.1017/cbo9780511626142 · Cited by 581
Antonini, J. M. (2003) · Critical Reviews in Toxicology · doi:10.1080/713611032 · Cited by 499 · cited 1×
“Exposure to different size fractions of particulate matter (PM) has adverse health effects on human health in environmental and occupational settings (Antonini 2003; Bhatti et al. 2011; Landen et al. 2011; Polichetti et al. 2009; Samet and Krewski 2007).”
Schwartz, J., & Neas, L. M. (2000) · Epidemiology · doi:10.1097/00001648-200001000-00004 · Cited by 471 · cited 5×
“welding fume, and 2,650 kg/m 3 for ARD (Sousan et al. 2016).”
Influential
Cited by
Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., et al. (2018) · Environment International · doi:10.1016/j.envint.2018.04.018 · Cited by 864
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Field and Laboratory Evaluations of the Low-Cost Plantower Particulate Matter Sensor
Levy Zamora, M., Xiong, F., Gentner, D., Kerkez, B., Kohrman-Glaser, J., & Koehler, K. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b05174 · Cited by 244
Self-citationBulot, F. M. J., Johnston, S. J., Basford, P. J., Easton, N. H. C., Apetroaie-Cristea, M., Foster, G. L., Morris, A. K. R., Cox, S. J., & Loxham, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-43716-3 · Cited by 241
Assessing the accuracy of low-cost optical particle sensors using a physics-based approach
Hagan, D. H., & Kroll, J. H. (2020) · Atmospheric Measurement Techniques · doi:10.5194/amt-13-6343-2020 · Cited by 231
“In practice, nephelometers are empirically calibrated by correlating the total scattered light signal with a reference mass measurement (Dacunto et al., 2015; Sousan et al., 2016b; Wang et al., 2015).”
BackgroundMethodA Review of Low-Cost Particulate Matter Sensors from the Developers’ Perspectives
Alfano, B., Barretta, L., Del Giudice, A., De Vito, S., Di Francia, G., Esposito, E., Formisano, F., Massera, E., Miglietta, M. L., & Polichetti, T. (2020) · Sensors · doi:10.3390/s20236819 · Cited by 202
“Honeywell/ HPMA115S0-XXX/ [67,122,129,130] Laser-based light scattering particle sensing/ indoor-automotive PM2.”
BackgroundInfluentialMagi, B. I., Cupini, C., Francis, J., Green, M., & Hauser, C. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1619915 · Cited by 192
“5 (Holstius et al. 2014; Snyder et al. 2013; Sousan et al. 2016; Woodall et al. 2017), speaking to the need for explicitly considering RH.”
BackgroundDeveloping a Relative Humidity Correction for Low-Cost Sensors Measuring Ambient Particulate Matter
Di Antonio, A., Popoola, O. A. M., Ouyang, B., Saffell, J., & Jones, R. L. (2018) · Sensors · doi:10.3390/s18092790 · Cited by 180
Patra, S. S., Nath, J., Panda, S., Das, T., & Ramasamy, B. (2022) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2021.1948459 · Cited by 15
Metadata
- Authors
- Sousan, S., Koehler, K., Hallett, L., & Peters, T. M.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2016-09-26
- Volume
- 50
- Issue
- 12
- Pages
- 1352-1365
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2512000668
- Cited by
- 210
- References
- 31
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.