CoChat

Evaluating the filtration efficiency of commercial facemasks’ materials against respiratory aerosol droplets

Patra, Satya S., Nath, Jyotishree, Panda, Subhasmita, Das, Trupti, Ramasamy, Boopathy · 2022 · Journal of the Air & Waste Management Association

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Respiratory droplets serve as a viable transmission mechanism for many viruses and other pathogens. Facemasks are commonly used to minimize the risk of this transmission. However, information on the size-resolved filtration efficiency of commonly available commercial facemasks is not readily available in the literature. To fill this gap, the current study performs aerosolized chamber experiments to evaluate the filtration efficiencies of commonly available commercial facemasks’ materials in a size range of 0.3–10 µm. Results rank the performance of filtration through commercial facemasks’ materials as follows (values in brackets indicate the average filtration efficiencies across 0.3–10 µm): 6-Layer N95 mask (0.918) > N95 mask – without valve (0.88) > KN95 mask (0.84) > N95 mask -with valve (0.834) > Heavy knitted cotton mask (0.808) > Surgical mask (0.778) > Cotton mask-2 layers (0.744) > Nylon fabric mask-2 layers (0.740) > T-shirt fabric mask-2 layers (0.708) > T-shirt fabric mask-1 layer (0.648). The size-resolved filtration efficiencies through the material across the evaluated commercial facemasks ranged from 38–83% in the size range of 0.3–0.5 µm, 55–88% in the size range of 0.5–1 µm, 69–93% in the size range of 1–2.5 µm, 76–96% in the size range of 2.5–5 µm, and 86–99% in the size range of 5–10 µm. Subsequently, the filtration efficiencies of materials post washing (with detergent in warm water and allowing to dry completely) were also evaluated. The average reduction…

Overview

Integrity signals

Registry

Crossref · 10.1080/10962247.2021.1948459

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 22 references

Cited by

See all 15

Metadata

Authors
Patra, S. S., Nath, J., Panda, S., Das, T., & Ramasamy, B.
Affiliations
  • Purdue University West Lafayette (US)
  • Institute of Minerals and Materials Technology (IN)
  • CSIR-Institute of Minerals and Materials Technology (CSIR-IMMT)
Venue
Journal of the Air & Waste Management Association
Published
2021-09-24
Volume
72
Issue
1
Pages
3-9
ISSN
  • 1047-3289 (ISSN-L)
  • 1096-2247
  • 2162-2906
OpenAlex
W3173363274
Cited by
15
References
20
Citations by year
2026: 1 · 2025: 3 · 2024: 4 · 2023: 2 · 2022: 3 · 2021: 2
FWCI
1.78
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of the Air & Waste Management Association (publishedVersion)
  • PubMed (publishedVersion)
Funders
OSPCB
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
  • Physical Sciences › Environmental Science › Global and Planetary Change › COVID-19 impact on air quality
Keywords
mask materials, aerosol filtration, respiratory protection, COVID-19 prevention, indoor air quality, PM2.5, atmospheric aerosols, airborne transmission
MeSH terms
Respiratory Aerosols and Droplets, Aerosols, Filtration, Masks, Respiratory Protective Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluating the filtration efficiency of commercial facemasks’ materials against respiratory aerosol droplets. https://app.cochat.ai/papers/10.1080/10962247.2021.1948459
The paper
Patra, S. S., Nath, J., Panda, S., Das, T., & Ramasamy, B. (2022). Evaluating the filtration efficiency of commercial facemasks’ materials against respiratory aerosol droplets. Journal of the Air & Waste Management Association. https://doi.org/10.1080/10962247.2021.1948459

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.