Mobility particle size spectrometers: Calibration procedures and measurement uncertainties
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Mobility particle size spectrometers (MPSS) belong to the essential instruments in aerosol science that determine the particle number size distribution (PNSD) in the submicrometer size range. Following calibration procedures and target uncertainties against standards and reference instruments are suggested for a complete MPSS quality assurance program: (a) calibration of the CPC counting efficiency curve (within 5% for the plateau counting efficiency; within 1 nm for the 50% detection efficiency diameter), (b) sizing calibration of the MPSS, using a certified polystyrene latex (PSL) particle size standard at 203 nm (within 3%), (c) intercomparison of the PNSD of the MPSS (within 10% and 20% of the dN/dlogDP concentration for the particle size range 20–200 and 200–800 nm, respectively), and (d) intercomparison of the integral PNC of the MPSS (within 10%). Furthermore, following measurement uncertainties have been investigated: (a) PSL particle size standards in the range from 100 to 500 nm match within 1% after sizing calibration at 203 nm. (b) Bipolar diffusion chargers based on the radioactive nuclides Kr85, Am241, and Ni63 and a new ionizer based on corona discharge follow the recommended bipolar charge distribution, while soft X-ray-based charges may alter faster than expected. (c) The use of a positive high voltage supply show a 10% better performance than a negative one. (d) The intercomparison of the integral PNC of an MPSS against the total number concentration is still within the target uncertainty at an ambient pressure of approximately 500 hPa.Copyright © 2018 Published with license by American Association for Aerosol Research
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerosol classification by electric mobility: apparatus, theory, and applications
Knutson, E. O., & Whitby, K. T. (1975) · Journal of Aerosol Science · doi:10.1016/0021-8502(75)90060-9 · Cited by 1,395 · cited 2×
“A DMA (see, e.g., Knutson and Whitby 1975; Liu and Pui 1974; Flagan 1999; Stolzenburg and McMurry 2008) is usually designed as a cylindrical capacitor in which charged aerosol is injected through an annular slit close to the outer electrode and merged with the particle-free and dried sheath air fl…”
An approximation of the bipolar charge distribution for particles in the submicron size range
Wiedensohler, A. (1988) · Journal of Aerosol Science · doi:10.1016/0021-8502(88)90278-9 · Cited by 947
Self-citationWiedensohler, A., Birmili, W., Nowak, A., Sonntag, A., Weinhold, K., Merkel, M., Wehner, B., Tuch, T., Pfeifer, S., Fiebig, M., et al. (2012) · Atmospheric Measurement Techniques · doi:10.5194/amt-5-657-2012 · Cited by 868
Self-citationAn Ultrafine Aerosol Condensation Nucleus Counter
Stolzenburg, M. R., & McMurry, P. H. (1991) · Aerosol Science and Technology · doi:10.1080/02786829108959470 · Cited by 440 · cited 2×
“The theoretical fi t function from Stolzenburg and McMurry (1991) is also given in the fi gure and was used for data interpretation.”
Generation of monodisperse Ag- and NaCl-aerosols with particle diameters between 2 and 300 nm
Scheibel, H. G., & ̈rfer, J. P. (1983) · Journal of Aerosol Science · doi:10.1016/0021-8502(83)90035-6 · Cited by 344
Continuous flow, single-particle-counting condensation nucleus counter
Agarwal, J. K., & Sem, G. J. (1980) · Journal of Aerosol Science · doi:10.1016/0021-8502(80)90042-7 · Cited by 334 · cited 1×
“Particles within a small electrical particle mobility bandwidth pass through the DMA and their number concentration is measured by the CPC (see, e.g., Agarwal and Sem 1980; Stolzenburg and McMurry 1991; Wieden-sohler et al. 1997; Hermann et al. 2007; Tuch et al. 2016).”
Stolzenburg, M. R., & McMurry, P. H. (2008) · Aerosol Science and Technology · doi:10.1080/02786820802157823 · Cited by 259 · cited 1×
“A DMA (see, e.g., Knutson and Whitby 1975; Liu and Pui 1974; Flagan 1999; Stolzenburg and McMurry 2008) is usually designed as a cylindrical capacitor in which charged aerosol is injected through an annular slit close to the outer electrode and merged with the particle-free and dried sheath air fl…”
Improved Inversion of Scanning DMA Data
Collins, D. R., Flagan, R. C., & Seinfeld, J. H. (2002) · Aerosol Science and Technology · doi:10.1080/027868202753339032 · Cited by 163 · cited 2×
“The “ DMA transfer function ” (Birmili et al. 1997; Collins et al. 2002; Hagwood et al. 1999; Knutson and Whitby 1975; Russell et al. 1995; Stolzenburg 1988; Zhang and Flagan 1996) can be described as a triangle selecting a range of electrical mobilities with an averaged transfer probability of 50%.”
Particle counting efficiencies of new TSI condensation particle counters
Hermann, M., Wehner, B., Bischof, O. F., Han, H.-S., Krinke, T., Liu, W., Zerrath, A., & Wiedensohler, A. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.05.001 · Cited by 112 · cited 1×
“Particles within a small electrical particle mobility bandwidth pass through the DMA and their number concentration is measured by the CPC (see, e.g., Agarwal and Sem 1980; Stolzenburg and McMurry 1991; Wieden-sohler et al. 1997; Hermann et al. 2007; Tuch et al. 2016).”
Self-citationAsymmetric Instrument Response Resulting from Mixing Effects in Accelerated DMA-CPC Measurements
Russell, L. M., Flagan, R. C., & Seinfeld, J. H. (1995) · Aerosol Science and Technology · doi:10.1080/02786829508965332 · Cited by 92 · cited 1×
“The “ DMA transfer function ” (Birmili et al. 1997; Collins et al. 2002; Hagwood et al. 1999; Knutson and Whitby 1975; Russell et al. 1995; Stolzenburg 1988; Zhang and Flagan 1996) can be described as a triangle selecting a range of electrical mobilities with an averaged transfer probability of 50%.”
Dependence of CPC cut-off diameter on particle morphology and other factors
Tuch, T., Weinhold, K., Merkel, M., Nowak, A. K., Klein, T., Quincey, P. G., Stolzenburg, M. R., & Wiedensohler, A. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1152351 · Cited by 32 · cited 4×
“Particles within a small electrical particle mobility bandwidth pass through the DMA and their number concentration is measured by the CPC (see, e.g., Agarwal and Sem 1980; Stolzenburg and McMurry 1991; Wiedensohler et al. 1997; Hermann et al. 2007; Tuch et al. 2016).”
InfluentialSelf-citation
Cited by
Global analysis of continental boundary layer new particle formation based on long-term measurements
Nieminen, T., Kerminen, V.-M., Petäjä, T., Aalto, P. P., Arshinov, M., Asmi, E., Baltensperger, U., Beddows, D. C. S., Beukes, J. P., Collins, D., et al. (2018) · Atmospheric Chemistry and Physics · doi:10.5194/acp-18-14737-2018 · Cited by 224
“In the literature, there are a few guidelines for ambient aerosol size-distribution measurements and quality assurance procedures (e.g., Wiedensohler et al., 2012, 2017), but not all of the measurement sites follow these guidelines.”
BackgroundSelf-citationRivas, I., Beddows, D. C. S., Amato, F., Green, D. C., Järvi, L., Hueglin, C., Reche, C., Timonen, H., Fuller, G. W., Niemi, J. V., et al. (2020) · Environment International · doi:10.1016/j.envint.2019.105345 · Cited by 215
“Commonly, α is used as a constant throughout all size bins and pollutants, however, we added higher uncertainty to the lowest and the highest bins of the PNSD as they have been reported to have increased measurement error (Wiedensohler et al., 2018).”
Schmale, J., Henning, S., Decesari, S., Henzing, B., Keskinen, H., Sellegri, K., Ovadnevaite, J., Pöhlker, M. L., Brito, J., Bougiatioti, A., et al. (2018) · Atmospheric Chemistry and Physics · doi:10.5194/acp-18-2853-2018 · Cited by 181
Self-citationA methodology to relate black carbon particle number and mass emissions
Teoh, R., Stettler, M. E. J., Majumdar, A., Schumann, U., Graves, B., & Boies, A. M. (2019) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2019.03.006 · Cited by 50
CAMP: an instrumented platform for balloon-borne aerosol particle studies in the lower atmosphere
Pilz, C., Düsing, S., Wehner, B., Müller, T., Siebert, H., Voigtländer, J., & Lonardi, M. (2022) · Atmospheric Measurement Techniques · doi:10.5194/amt-15-6889-2022 · Cited by 20
Metadata
- Authors
- Wiedensohler, A., Wiesner, A., Weinhold, K., Birmili, W., Hermann, M., Merkel, M., Müller, T., Pfeifer, S., Schmidt, A., Tuch, T., Velarde, F., Quincey, P., Seeger, S., & Nowak, A.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2017-10-26
- Volume
- 52
- Issue
- 2
- Pages
- 146-164
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W2762097185
- Cited by
- 190
- References
- 11
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.