Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Influence of gray level discretization on radiomic feature stability for different CT scanners, tube currents and slice thicknesses: a comprehensive phantom study

Open access
Larue, Ruben T. H. M., van Timmeren, Janna E., de Jong, Evelyn E. C., Feliciani, Giacomo, Leijenaar, Ralph T. H., Schreurs, Wendy M. J., Sosef, Meindert N., Raat, Frank H. P. J., van der Zande, Frans H. R., Das, Marco, van Elmpt, Wouter, Lambin, Philippe·2017·Acta Oncologica

Abstract

Background: Radiomic analyses of CT images provide prognostic information that can potentially be used for personalized treatment. However, heterogeneity of acquisition- and reconstruction protocols influences robustness of radiomic analyses. The aim of this study was to investigate the influence of different CT-scanners, slice thicknesses, exposures and gray-level discretization on radiomic feature values and their stability.Material and methods: A texture phantom with ten different inserts was scanned on nine different CT-scanners with varying tube currents. Scans were reconstructed with 1.5 mm or 3 mm slice thickness. Image pre-processing comprised gray-level discretization in ten different bin widths ranging from 5 to 50 HU and different resampling methods (i.e., linear, cubic and nearest neighbor interpolation to 1 × 1 × 3 mm3 voxels) were investigated. Subsequently, 114 textural radiomic features were extracted from a 2.1 cm3 sphere in the center of each insert. The influence of slice thickness, exposure and bin width on feature values was investigated. Feature stability was assessed by calculating the concordance correlation coefficient (CCC) in a test-retest setting and for different combinations of scanners, tube currents and slice thicknesses.Results: Bin width influenced feature values, but this only had a marginal effect on the total number of stable features (CCC > 0.85) when comparing different scanners, slice thicknesses or exposures. Most radiomic features were affected by slice thickness, but this effect could be reduced by resampling the CT-images before feature extraction. Statistics feature ‘energy’ was the most dependent on slice thickness. No clear correlation between feature values and exposures was observed.Conclusions: CT-scanner, slice thickness and bin width affected radiomic feature values, whereas no effect of exposure was observed. Optimization of gray-level discretization to potentially improve prognostic value can be performed without compromising feature stability. Resampling images prior to feature extraction decreases the variability of radiomic features.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/0284186x.2017.1351624

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 262

Metadata

Authors
Larue, R. T. H. M., van Timmeren, J. E., de Jong, E. E. C., Feliciani, G., Leijenaar, R. T. H., Schreurs, W. M. J., Sosef, M. N., Raat, F. H. P. J., van der Zande, F. H. R., Das, M., van Elmpt, W., & Lambin, P.
Venue
Acta Oncologica
Published
2017-09-08
Volume
56
Issue
11
Pages
1544-1553
ISSN
  • 0284-186X (ISSN-L)
  • 1651-226X
OpenAlex
W2753416097
Cited by
262
References
17
FWCI
14.96
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of gray level discretization on radiomic feature stability for different CT scanners, tube currents and slice thicknesses: a comprehensive phantom study. https://app.cochat.ai/papers/10.1080/0284186x.2017.1351624
The paper
Larue, R. T. H. M., van Timmeren, J. E., de Jong, E. E. C., Feliciani, G., Leijenaar, R. T. H., Schreurs, W. M. J., Sosef, M. N., Raat, F. H. P. J., van der Zande, F. H. R., Das, M., van Elmpt, W., & Lambin, P. (2017). Influence of gray level discretization on radiomic feature stability for different CT scanners, tube currents and slice thicknesses: a comprehensive phantom study. Acta Oncologica. https://doi.org/10.1080/0284186x.2017.1351624

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.