Influence of gray level discretization on radiomic feature stability for different CT scanners, tube currents and slice thicknesses: a comprehensive phantom study
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background: Radiomic analyses of CT images provide prognostic information that can potentially be used for personalized treatment. However, heterogeneity of acquisition- and reconstruction protocols influences robustness of radiomic analyses. The aim of this study was to investigate the influence of different CT-scanners, slice thicknesses, exposures and gray-level discretization on radiomic feature values and their stability.Material and methods: A texture phantom with ten different inserts was scanned on nine different CT-scanners with varying tube currents. Scans were reconstructed with 1.5 mm or 3 mm slice thickness. Image pre-processing comprised gray-level discretization in ten different bin widths ranging from 5 to 50 HU and different resampling methods (i.e., linear, cubic and nearest neighbor interpolation to 1 × 1 × 3 mm3 voxels) were investigated. Subsequently, 114 textural radiomic features were extracted from a 2.1 cm3 sphere in the center of each insert. The influence of slice thickness, exposure and bin width on feature values was investigated. Feature stability was assessed by calculating the concordance correlation coefficient (CCC) in a test-retest setting and for different combinations of scanners, tube currents and slice thicknesses.Results: Bin width influenced feature values, but this only had a marginal effect on the total number of stable features (CCC > 0.85) when comparing different scanners, slice thicknesses or exposures. Most radiomic features were affected by slice thickness, but this effect could be reduced by resampling the CT-images before feature extraction. Statistics feature ‘energy’ was the most dependent on slice thickness. No clear correlation between feature values and exposures was observed.Conclusions: CT-scanner, slice thickness and bin width affected radiomic feature values, whereas no effect of exposure was observed. Optimization of gray-level discretization to potentially improve prognostic value can be performed without compromising feature stability. Resampling images prior to feature extraction decreases the variability of radiomic features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 1×
“Moreover, the pairwise concordance correlation coefficient (CCC) [15] was used to determine the agreement in feature values over all inserts when comparing (1) a slice thickness of 1.”
MethodRadiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Self-citationDecoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Self-citationCT-based radiomic signature predicts distant metastasis in lung adenocarcinoma
Coroller, T. P., Grossmann, P., Hou, Y., Rios Velazquez, E., Leijenaar, R. T. H., Hermann, G., Lambin, P., Haibe-Kains, B., Mak, R. H., & Aerts, H. J. W. L. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.02.015 · Cited by 695
Self-citationMeasuring Computed Tomography Scanner Variability of Radiomics Features
Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000180 · Cited by 651
Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels
Shafiq‐ul‐Hassan, M., Zhang, G. G., Latifi, K., Ullah, G., Hunt, D. C., Balagurunathan, Y., Abdalah, M. A., Schabath, M. B., Goldgof, D. G., Mackin, D., et al. (2017) · Medical Physics · doi:10.1002/mp.12123 · Cited by 585
Reproducibility of radiomics for deciphering tumor phenotype with imaging
Zhao, B., Tan, Y., Tsai, W.-Y., Qi, J., Xie, C., Lu, L., & Schwartz, L. H. (2016) · Scientific Reports · doi:10.1038/srep23428 · Cited by 509
Leijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Self-citationLeijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Self-citationLarue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
Self-citation
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Self-citationRadiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Radiomics: the facts and the challenges of image analysis
Rizzo, S., Botta, F., Raimondi, S., Origgi, D., Fanciullo, C., Morganti, A. G., & Bellomi, M. (2018) · European Radiology Experimental · doi:10.1186/s41747-018-0068-z · Cited by 1,054
Liu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Radiomics in Oncology: A Practical Guide
Shur, J. D., Doran, S. J., Kumar, S., ap Dafydd, D., Downey, K., O’Connor, J. P. B., Papanikolaou, N., Messiou, C., Koh, D.-M., & Orton, M. R. (2021) · RadioGraphics · doi:10.1148/rg.2021210037 · Cited by 378
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
Assessing robustness of radiomic features by image perturbation
Zwanenburg, A., Leger, S., Agolli, L., Pilz, K., Troost, E. G. C., Richter, C., & Löck, S. (2019) · Scientific Reports · doi:10.1038/s41598-018-36938-4 · Cited by 242
“Larue et al . and Mackin et al . both found that exposure had a marginal effect on feature robustness 18,19 , whereas Midya et al . found that it had a more pronounced effect 20 .”
BackgroundCriteria for the translation of radiomics into clinically useful tests
Huang, E. P., O’Connor, J. P. B., McShane, L. M., Giger, M. L., Lambin, P., Kinahan, P. E., Siegel, E. L., & Shankar, L. K. (2023) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00707-0 · Cited by 230
Self-citationVoxel size and gray level normalization of CT radiomic features in lung cancer
Shafiq-ul-Hassan, M., Latifi, K., Zhang, G., Ullah, G., Gillies, R., & Moros, E. (2018) · Scientific Reports · doi:10.1038/s41598-018-28895-9 · Cited by 215
Kim, S., Shin, J., Kim, D.-Y., Choi, G. H., Kim, M.-J., & Choi, J.-Y. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-18-2861 · Cited by 205
Fornacon-Wood, I., Mistry, H., Ackermann, C. J., Blackhall, F., McPartlin, A., Faivre-Finn, C., Price, G. J., & O’Connor, J. P. B. (2020) · European Radiology · doi:10.1007/s00330-020-06957-9 · Cited by 198
Hagiwara, A., Fujita, S., Ohno, Y., & Aoki, S. (2020) · Investigative Radiology · doi:10.1097/rli.0000000000000666 · Cited by 183
“However, the selection of interpolationmethods (eg, nearest neighbor, trilinear and tricubic interpolation) has been revealed to affect the reproducibility of radiomic features.(209) Also, how the software treats the boundary of the volume of interest also affects radiomic features; when the voxels outside the ROI are…”
BackgroundXie, C., Yang, P., Zhang, X., Xu, L., Wang, X., Li, X., Zhang, L., Xie, R., Yang, L., Jing, Z., et al. (2019) · eBioMedicine · doi:10.1016/j.ebiom.2019.05.023 · Cited by 176
“To compensate for the difference in radiomics features caused by different reconstruction slice thicknesses andpixel sizes [16], the voxel sizes of all CT images in this study were reconstructed to 1 × 1 × 5 mm(3).”
MethodRepeatability and reproducibility of MRI-based radiomic features in cervical cancer
Fiset, S., Welch, M. L., Weiss, J., Pintilie, M., Conway, J. L., Milosevic, M., Fyles, A., Traverso, A., Jaffray, D., Metser, U., et al. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.03.001 · Cited by 167
Understanding Sources of Variation to Improve the Reproducibility of Radiomics
Zhao, B. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.633176 · Cited by 158
Radiomics in radiooncology – challenging the medical physicist
Peeken, J. C., Bernhofer, M., Wiestler, B., Goldberg, T., Cremers, D., Rost, B., Wilkens, J. J., Combs, S. E., & Nüsslin, F. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.03.012 · Cited by 98
Influence of scan mode, tilt, and radiation dose on CT radiomic metrics
Yadav, N., Lei, X., Cen, S. Y., Levy, J., Jensen, K., & Varghese, B. A. (2026) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.70462 · Cited by 1
Metadata
- Authors
- Larue, R. T. H. M., van Timmeren, J. E., de Jong, E. E. C., Feliciani, G., Leijenaar, R. T. H., Schreurs, W. M. J., Sosef, M. N., Raat, F. H. P. J., van der Zande, F. H. R., Das, M., van Elmpt, W., & Lambin, P.
- Venue
- Acta Oncologica
- Published
- 2017-09-08
- Volume
- 56
- Issue
- 11
- Pages
- 1544-1553
- ISSN
- 0284-186X (ISSN-L)
- 1651-226X
- OpenAlex
- W2753416097
- Cited by
- 262
- References
- 17
- FWCI
- 14.96
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.