Influence of inter-observer delineation variability on radiomics stability in different tumor sites
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Radiomics is a promising methodology for quantitative analysis and description of radiological images using advanced mathematics and statistics. Tumor delineation, which is still often done manually, is an essential step in radiomics, however, inter-observer variability is a well-known uncertainty in radiation oncology. This study investigated the impact of inter-observer variability (IOV) in manual tumor delineation on the reliability of radiomic features (RF). METHODS: Three different tumor types (head and neck squamous cell carcinoma (HNSCC), malignant pleural mesothelioma (MPM) and non-small cell lung cancer (NSCLC)) were included. For each site, eleven individual tumors were contoured on CT scans by three experienced radiation oncologists. Dice coefficients (DC) were calculated for quantification of delineation variability. RF were calculated with an in-house developed software implementation, which comprises 1404 features: shape (n = 18), histogram (n = 17), texture (n = 137) and wavelet (n = 1232). The IOV of RF was studied using the intraclass correlation coefficient (ICC). An ICC >0.8 indicates a good reproducibility. For the stable RF, an average linkage hierarchical clustering was performed to identify classes of uncorrelated features. RESULTS: Median DC was high for NSCLC (0.86, range 0.57-0.90) and HNSCC (0.72, 0.21-0.89), whereas it was low for MPM (0.26, 0-0.9) indicating substantial IOV. Stability rate of RF correlated with DC and depended on tumor site, showing a high stability in NSCLC (90% of total parameters), acceptable stability in HNSCC (59% of total parameters) and low stability in MPM (36% of total parameters). Shape features showed the weakest stability across all tumor types. Hierarchical clustering revealed 14 groups of correlated and stable features for NSCLC and 6 groups for both HNSCC and MPM. CONCLUSION: Inter-observer delineation variability has a relevant influence on radiomics analysis and is strongly influenced by tumor type. This leads to a reduced number of suitable imaging features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709 · cited 1×
“75 is indicative of a good reliability [20].”
BackgroundIntraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874 · cited 1×
“A value of 0 indicates no overlap, whereas a value of 1 indicates identical contours [15].”
BackgroundRadiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084 · cited 1×
“Radiomics is a method to describe and quantify shape, intensity and texture of a tumor by extracting and analyzing hundreds of quantitative features from radiological images [3].”
MethodApplications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation
Parmar, C., Rios Velazquez, E., Leijenaar, R., Jermoumi, M., Carvalho, S., Mak, R. H., Mitra, S., Shankar, B. U., Kikinis, R., Haibe-Kains, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102107 · Cited by 611 · cited 1×
“Moreover, the use of automatic image delineation may also lead to a reduction of contouring variability and therefore its introduction to contouring process should be considered [28].”
BackgroundCharacterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Leijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Larue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286 · cited 1×
“of radiomics analysis in NSCLC delineated manually on CT scans and semi-automatically on PET images additionally to the impact of two different reconstruction methods for the PET scans [12].”
MethodDefinition of gross tumor volume in lung cancer: inter-observer variability
Van de Steene, J., Linthout, N., de Mey, J., Vinh-Hung, V., Claassens, C., Noppen, M., Bel, A., & Storme, G. (2002) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00453-4 · Cited by 255 · cited 1×
“For NSCLC, literature describes a larger variability in contouring than we have found in our study [10,21,22].”
ResultCancer stem cells: understanding tumor hierarchy and heterogeneity
Rich, J. N. (2016) · Medicine · doi:10.1097/md.0000000000004764 · Cited by 243
Variability of gross tumor volume delineation in head-and-neck cancer using CT and PET/CT fusion
Riegel, A. C., Berson, A. M., Destian, S., Ng, T., Tena, L. B., Mitnick, R. J., & Wong, P. S. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.01.014 · Cited by 242 · cited 1×
“The contour overlap ranged from 7% to 60% [24].”
BackgroundGiraud, P., Elles, S., Helfre, S., De Rycke, Y., Servois, V., Carette, M.-F., Alzieu, C., Bondiau, P.-Y., Dubray, B., Touboul, E., et al. (2002) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00444-3 · Cited by 223 · cited 1×
“For NSCLC, literature describes a larger variability in contouring than we have found in our study [10,21,22].”
Result3D Variation in delineation of head and neck organs at risk
Brouwer, C. L., Steenbakkers, R. J., van den Heuvel, E., Duppen, J. C., Navran, A., Bijl, H. P., Chouvalova, O., Burlage, F. R., Meertens, H., Langendijk, J. A., et al. (2012) · Radiation Oncology · doi:10.1186/1748-717x-7-32 · Cited by 211
Hatt, M., Tixier, F., Cheze Le Rest, C., Pradier, O., & Visvikis, D. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2486-8 · Cited by 208
Bogowicz, M., Riesterer, O., Stark, L. S., Studer, G., Unkelbach, J., Gückenberger, M., & Tanadini‐Lang, S. (2017) · Acta Oncologica · doi:10.1080/0284186x.2017.1346382 · Cited by 166
Self-citationSenan, S., de Koste, J. R. V. S., Samson, M. J., Tankink, H., Jansen, P. P., Nowak, P. J. C. M., Krol, A. D. G., Schmitz, P. I. M., & Lagerwaard, F. J. (1999) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(99)00143-7 · Cited by 147
Bogowicz, M., Leijenaar, R. T. H., Tanadini‐Lang, S., Riesterer, O., Pruschy, M. N., Studer, G., Unkelbach, J., Gückenberger, M., Konukoğlu, E., & Lambin, P. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.10.023 · Cited by 119
Self-citationThe delineation of target volumes for radiotherapy of lung cancer patients
Vorwerk, H., Beckmann, G. K., Bremer, M., Degen, M., Dietl, B., Fietkau, R., Gsänger, T., Hermann, R. M., Herrmann, M. K. A., Höller, U., et al. (2009) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2009.03.014 · Cited by 100 · cited 1×
“For NSCLC, literature describes a larger variability in contouring than we have found in our study [10,21,22].”
ResultFuller, C. D., Nijkamp, J. A., Duppen, J. C., Rasch, C. R. N., Thomas, C. R., Wang, S. J., Okunieff, P. G., Jones, W. E., Baseman, D., Patel, S. A., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.11.012 · Cited by 97 · cited 1×
“There is evidence that using contouring protocols or guidelines is able to reduce inter-observer variation in target volume delineation [26,27].”
BackgroundRachiglio, A. M., Abate, R. E., Sacco, A., Pasquale, R., Fenizia, F., Lambiase, M., Morabito, A., Montanino, A., Rocco, G., Romano, C., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.10704 · Cited by 97 · cited 1×
“Heterogeneity, not only between tumors but also within a tumor, is a well-known cancer-related phenomenon and was hypothesized to be one of the major causes for the varying effectiveness of anticancer treatment [1,2].”
BackgroundWalter (1998) · doi:10.1002/(sici)1097-0258(19980115)17:1<101::aid-sim727>3.0.co;2-e
Cited by
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Self-citationPark, J. E., Park, S. Y., Kim, H. J., & Kim, H. S. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0070 · Cited by 388
Ibrahim, A., Primakov, S., Beuque, M., Woodruff, H. C., Halilaj, I., Wu, G., Refaee, T., Granzier, R., Widaatalla, Y., Hustinx, R., et al. (2021) · Methods · doi:10.1016/j.ymeth.2020.05.022 · Cited by 265
Meyer, M., Ronald, J., Vernuccio, F., Nelson, R. C., Ramirez-Giraldo, J. C., Solomon, J., Patel, B. N., Samei, E., & Marin, D. (2019) · Radiology · doi:10.1148/radiol.2019190928 · Cited by 258
Assessing robustness of radiomic features by image perturbation
Zwanenburg, A., Leger, S., Agolli, L., Pilz, K., Troost, E. G. C., Richter, C., & Löck, S. (2019) · Scientific Reports · doi:10.1038/s41598-018-36938-4 · Cited by 242
“23 .”
Background
Metadata
- Authors
- Pavic, M., Bogowicz, M., Würms, X., Glatz, S., Finazzi, T., Riesterer, O., Roesch, J., Rudofsky, L., Friess, M., Veit-Haibach, P., Huellner, M., Opitz, I., Weder, W., Frauenfelder, T., Guckenberger, M., & Tanadini-Lang, S.
- Venue
- Acta Oncologica
- Published
- 2018-03-07
- Volume
- 57
- Issue
- 8
- Pages
- 1070-1074
- ISSN
- 0284-186X (ISSN-L)
- 1651-226X
- OpenAlex
- W2791459212
- Cited by
- 203
- References
- 23
- FWCI
- 15.43
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.