Effect of Amplitude and Frequency of Cyclic Tensile Strain on the Inhibition of MMP-1 mRNA Expression in Tendon Cells: An In Vitro Study
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
To determine the effect of cyclic strain amplitude and frequency on MMP-1 (interstitial collagenase) expression in tendon cells, rat tail tendons (RTT) were immobilized or cyclically displaced to various amplitudes (1, 3, or 6% strain at 0.017 Hz) or frequencies (1% strain at 0.017, 0.17, or 1.0 Hz) for 24 hr. Stress-deprivation for 24 hr resulted in a marked upregulation in MMP-1 expression. Cyclic tensile loading at 0.017 Hz was found to significantly inhibit, but not completely eliminate, MMP-1 expression at 1% strain. MMP-1 expression was completely eliminated at 3 and 6% strain. Increasing the frequency of application of the 1% strain to 0.17 or 1.0 Hz completely eliminated MMP-1 expression. Disruption of the actin cytoskeleton with cytochalasin D abolished all inhibitory effects of cyclic strain on MMP-1 expression. The results of our study demonstrate that MMP-1 expression in tendon cells can be modulated by varying amplitudes and frequencies of cyclic tensile strain, presumably through a cytoskeletally based mechanotransduction pathway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanotransduction Across the Cell Surface and Through the Cytoskeleton
Wang, N., Butler, J. P., & Ingber, D. E. (1993) · Science · doi:10.1126/science.7684161 · Cited by 3,003
Effects of mechanical forces on maintenance and adaptation of form in trabecular bone
Huiskes, R., Ruimerman, R., van Lenthe, G. H., & Janssen, J. D. (2000) · Nature · doi:10.1038/35015116 · Cited by 1,180
Mechanotransduction in bone—role of the lacunocanalicular network
Burger, E. H., & Klein‐Nulend, J. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.9001.s101 · Cited by 897
The Multicomposite Structure of Tendon
Kastelic, J., Galeski, A., & Baer, E. (1978) · Connective Tissue Research · doi:10.3109/03008207809152283 · Cited by 689 · cited 1×
“Since tendons are known to exhibit nonhomogenous strain pattern in response to tensile load [43], it is impossible to determine precise amplitudes of strain experienced by the cells based on overall tendon strain.”
BackgroundMechanotransduction in bone: osteoblasts are more responsive to fluid forces than mechanical strain
Owan, I., Burr, D. B., Turner, C. H., Qiu, J., Tu, Y., Onyia, J. E., & Duncan, R. L. (1997) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1997.273.3.c810 · Cited by 467 · cited 2×
“Transmission of tissue strain to the extracellular matrix and cells is believed to have two potential modes: substrate (extracellular matrix) strain and fluid flow [10, 12, 16, 17, 22, 29, 30, 33, 36, 39].”
BackgroundDifferential effect of steady versus oscillating flow on bone cells
Jacobs, C. R., Yellowley, C. E., Davis, B. R., Zhou, Z., Cimbala, J. M., & Donahue, H. J. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00114-6 · Cited by 453
Effects of Loading Frequency on Mechanically Induced Bone Formation
Hsieh, Y.-F., & Turner, C. H. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.5.918 · Cited by 370
Banes, A. J., Tsuzaki, M., Yamamoto, J., Brigman, B., Fischer, T., Brown, T., & Miller, L. (1995) · Biochemistry and Cell Biology · doi:10.1139/o95-043 · Cited by 369 · cited 1×
“Transmission of tissue strain to the extracellular matrix and cells is believed to have two potential modes: substrate (extracellular matrix) strain and fluid flow [10, 12, 16, 17, 22, 29, 30, 33, 36, 39].”
BackgroundYou, J., Yellowley, C. E., Donahue, H. J., Zhang, Y., Chen, Q., & Jacobs, C. R. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1287161 · Cited by 357 · cited 5×
“2%) of tissue strain, fluid flow is a more potent stimulator of bone cells than is matrix deformation itself [17].”
BackgroundInfluentialFunction follows form: generation of intracellular signals by cell deformation
Watson, P. A. (1991) · The FASEB Journal · doi:10.1096/fasebj.5.7.1707019 · Cited by 346 · cited 1×
“Transmission of tissue strain to the extracellular matrix and cells is believed to have two potential modes: substrate (extracellular matrix) strain and fluid flow [10, 12, 16, 17, 22, 29, 30, 33, 36, 39].”
Cited by
Wang, J. H.-C. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.011 · Cited by 1,002
Kongsgaard, M., Kovanen, V., Aagaard, P., Doessing, S., Hansen, P., Laursen, A. H., Kaldau, N. C., Kjaer, M., & Magnusson, S. P. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2009.00949.x · Cited by 471
Bohm, S., Mersmann, F., & Arampatzis, A. (2015) · Sports Medicine - Open · doi:10.1186/s40798-015-0009-9 · Cited by 458
Mechanotherapy: how physical therapists’ prescription of exercise promotes tissue repair
Khan, K. M., & Scott, A. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.054239 · Cited by 434
Snedeker, J. G., & Foolen, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.08.032 · Cited by 377
Arampatzis, A., Karamanidis, K., & Albracht, K. (2007) · Journal of Experimental Biology · doi:10.1242/jeb.003814 · Cited by 354
“, 2004), stimulation of the gene expression of inflammatory mediators such as interstitial collagenase (Lavagnino et al., 2003) or prostaglandin E2 (Wang et al.”
BackgroundMechanoactive Tenogenic Differentiation of Human Mesenchymal Stem Cells
Kuo, C. K., & Tuan, R. S. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2006.0415 · Cited by 305
Jones, G. C., Corps, A. N., Pennington, C. J., Clark, I. M., Edwards, D. R., Bradley, M. M., Hazleman, B. L., & Riley, G. P. (2006) · Arthritis & Rheumatism · doi:10.1002/art.21672 · Cited by 292
Zaffagnini, S., Marcacci, M., Lo Presti, M., Giordano, G., Iacono, F., & Neri, M. P. (2006) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-006-0130-x · Cited by 207
“Recently Arnoczky [5] and Lavagnino [ 30 ] have demonstrated that the biological response of cells and the ultimate remodeling of the ACL graft appear to be governed in large part by the mechanical environment to which the graft is exposed.”
BackgroundProgress in cell-based therapies for tendon repair
Gaspar, D., Spanoudes, K., Holladay, C., Pandit, A., & Zeugolis, D. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.11.023 · Cited by 189
Biomechanical Basis for Tendinopathy
Wang, J. H.-C., Iosifidis, M. I., & Fu, F. H. (2006) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000195927.81845.46 · Cited by 174
Tendon mechanobiology: Current knowledge and future research opportunities
Lavagnino, M., Wall, M. E., Little, D., Banes, A. J., Guilak, F., & Arnoczky, S. P. (2015) · Journal of Orthopaedic Research · doi:10.1002/jor.22871 · Cited by 160
Self-citationTsai, M.-S., Domroes, T., Pentidis, N., Koschinski, S., Schroll, A., Bohm, S., Arampatzis, A., & Mersmann, F. (2024) · Scientific Reports · doi:10.1038/s41598-024-56840-6 · Cited by 12
Metadata
- Authors
- Lavagnino, M., Arnoczky, S. P., Tian, T., & Vaupel, Z.
- Venue
- Connective Tissue Research
- Publisher
- Informa UK Limited
- Published
- 2003-01
- Volume
- 44
- Issue
- 3-4
- Pages
- 181-187
- ISSN
- 0300-8207 (ISSN-L)
- 1607-8438
- OpenAlex
- W2033673494
- Cited by
- 175
- References
- 32
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.