Effect of Amplitude and Frequency of Cyclic Tensile Strain on the Inhibition of MMP-1 mRNA Expression in Tendon Cells: An In Vitro Study
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
To determine the effect of cyclic strain amplitude and frequency on MMP-1 (interstitial collagenase) expression in tendon cells, rat tail tendons (RTT) were immobilized or cyclically displaced to various amplitudes (1, 3, or 6% strain at 0.017 Hz) or frequencies (1% strain at 0.017, 0.17, or 1.0 Hz) for 24 hr. Stress-deprivation for 24 hr resulted in a marked upregulation in MMP-1 expression. Cyclic tensile loading at 0.017 Hz was found to significantly inhibit, but not completely eliminate, MMP-1 expression at 1% strain. MMP-1 expression was completely eliminated at 3 and 6% strain. Increasing the frequency of application of the 1% strain to 0.17 or 1.0 Hz completely eliminated MMP-1 expression. Disruption of the actin cytoskeleton with cytochalasin D abolished all inhibitory effects of cyclic strain on MMP-1 expression. The results of our study demonstrate that MMP-1 expression in tendon cells can be modulated by varying amplitudes and frequencies of cyclic tensile strain, presumably through a cytoskeletally based mechanotransduction pathway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanotransduction Across the Cell Surface and Through the Cytoskeleton
Wang, N., Butler, J. P., & Ingber, D. E. (1993) · Science · doi:10.1126/science.7684161 · Cited by 3,003
Effects of mechanical forces on maintenance and adaptation of form in trabecular bone
Huiskes, R., Ruimerman, R., van Lenthe, G. H., & Janssen, J. D. (2000) · Nature · doi:10.1038/35015116 · Cited by 1,180
Mechanotransduction in bone—role of the lacunocanalicular network
Burger, E. H., & Klein‐Nulend, J. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.9001.s101 · Cited by 897
The Multicomposite Structure of Tendon
Kastelic, J., Galeski, A., & Baer, E. (1978) · Connective Tissue Research · doi:10.3109/03008207809152283 · Cited by 689 · cited 1×
“Since tendons are known to exhibit nonhomogenous strain pattern in response to tensile load [43], it is impossible to determine precise amplitudes of strain experienced by the cells based on overall tendon strain.”
BackgroundMechanotransduction in bone: osteoblasts are more responsive to fluid forces than mechanical strain
Owan, I., Burr, D. B., Turner, C. H., Qiu, J., Tu, Y., Onyia, J. E., & Duncan, R. L. (1997) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1997.273.3.c810 · Cited by 467 · cited 2×
“Transmission of tissue strain to the extracellular matrix and cells is believed to have two potential modes: substrate (extracellular matrix) strain and fluid flow [10, 12, 16, 17, 22, 29, 30, 33, 36, 39].”
BackgroundDifferential effect of steady versus oscillating flow on bone cells
Jacobs, C. R., Yellowley, C. E., Davis, B. R., Zhou, Z., Cimbala, J. M., & Donahue, H. J. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00114-6 · Cited by 453
Effects of Loading Frequency on Mechanically Induced Bone Formation
Hsieh, Y.-F., & Turner, C. H. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.5.918 · Cited by 370
Banes, A. J., Tsuzaki, M., Yamamoto, J., Brigman, B., Fischer, T., Brown, T., & Miller, L. (1995) · Biochemistry and Cell Biology · doi:10.1139/o95-043 · Cited by 369 · cited 1×
“Transmission of tissue strain to the extracellular matrix and cells is believed to have two potential modes: substrate (extracellular matrix) strain and fluid flow [10, 12, 16, 17, 22, 29, 30, 33, 36, 39].”
BackgroundYou, J., Yellowley, C. E., Donahue, H. J., Zhang, Y., Chen, Q., & Jacobs, C. R. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1287161 · Cited by 357 · cited 5×
“2%) of tissue strain, fluid flow is a more potent stimulator of bone cells than is matrix deformation itself [17].”
BackgroundInfluentialFunction follows form: generation of intracellular signals by cell deformation
Watson, P. A. (1991) · The FASEB Journal · doi:10.1096/fasebj.5.7.1707019 · Cited by 346 · cited 1×
“Transmission of tissue strain to the extracellular matrix and cells is believed to have two potential modes: substrate (extracellular matrix) strain and fluid flow [10, 12, 16, 17, 22, 29, 30, 33, 36, 39].”
Cell shape, cytoskeletal mechanics, and cell cycle control in angiogenesis
Ingber, D. E., Prusty, D., Sun, Z., Betensky, H., & Wang, N. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00095-x · Cited by 336
Rubin, C., Xu, G., & Judex, S. (2001) · The FASEB Journal · doi:10.1096/fj.01-0166com · Cited by 313 · cited 1×
“These findings have led to the successful application of low amplitude, high frequency mechanical stimulation in bone to inhibit catabolism [18].”
BackgroundMechanical transduction in biological systems.
Sachs, F. (1988) · PubMed · Cited by 299
Recruitment of Tendon Crimp With Applied Tensile Strain
Hansen, K. A., Weiss, J. A., & Barton, J. K. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427698 · Cited by 285 · cited 2×
“Studies have shown that in rat tail tendons even local tissue strain is nonhomogenous throughout the depth of the tendon [33, 37].”
BackgroundNeidlinger‐Wilke, C., Wilke, H., & Claes, L. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120109 · Cited by 258
Amiel, D., Woo, S. L.-Y., Harwood, F. L., & Akeson, W. H. (1982) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678208992224 · Cited by 233
Real-time calcium response of cultured bone cells to fluid flow.
Hung, C. T., Pollack, S. R., Reilly, T. M., & Brighton, C. T. (1995) · PubMed · Cited by 227
Changes in cell shape correlate with collagenase gene expression in rabbit synovial fibroblasts.
Aggeler, J., Frisch, S. M., & Werb, Z. (1984) · The Journal of cell biology · doi:10.1083/jcb.98.5.1662 · Cited by 225 · cited 3×
“Procollagenase expression in rabbit synovial fibroblasts was induced by treatments that modified cellular actin [44].”
BackgroundPDGF-BB, IGF-I and mechanical load stimulate DNA synthesis in avian tendon fibroblasts in vitro
Banes, A. J., Tsuzaki, M., Hu, P., Brigman, B., Brown, T., Almekinders, L., Lawrence, W. T., & Fischer, T. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00098-4 · Cited by 221 · cited 2×
“Transmission of tissue strain to the extracellular matrix and cells is believed to have two potential modes: substrate (extracellular matrix) strain and fluid flow [10, 12, 16, 17, 22, 29, 30, 33, 36, 39].”
BackgroundArnoczky, S. P., Tian, T., Lavagnino, M., Gardner, K., Schuler, P., & Morse, P. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00038-4 · Cited by 195 · cited 1×
“Application of load to bone [11, 14, 18, 23–25], ligament [25–27], and tendon [5, 10, 28, 29] has been implicated in the maintenance of tissue homeostasis.”
BackgroundSelf-citationBrighton, C. T., Strafford, B., Gross, S. B., Leatherwood, D. F., Williams, J. L., & Pollack, S. R. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173030-00002 · Cited by 191
Hannafin, J. A., Arnoczky, S. P., Hoonjan, A., & Torzilli, P. A. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130615 · Cited by 175
Self-citationHannafin, J. A., & ARNOCZKY, S. P. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120307 · Cited by 149 · cited 1×
“While cyclic strain-induced fluid flow in bone occurs through a patent and well-developed canalicular network, the flow of interstitial fluid in response to cyclic loading is less defined in tendons [19, 22].”
BackgroundSelf-citationResponses of Bone Cells to Biomechanical Forces in Vitro
Burger, E. H., & Klein‐Nulend, J. (1999) · Advances in Dental Research · doi:10.1177/08959374990130012201 · Cited by 145
Arnoczky, S. P., Lavagnino, M., Whallon, J. H., & Hoonjan, A. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00080-8 · Cited by 143 · cited 4×
“Studies have shown that in rat tail tendons even local tissue strain is nonhomogenous throughout the depth of the tendon [33, 37].”
BackgroundInfluentialSelf-citationHsieh, A. H., Tsai, C. M., Ma, Q., Lin, T., Banes, A. J., Villarreal, F. J., Akeson, W. H., & Paul Sung, K. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180209 · Cited by 128
The effects of frequency and duration of controlled passive mobilization on tendon healing
Takai, S., Woo, S. L., Horibe, S., Tung, D. K., & Gelberman, R. H. (1991) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100090510 · Cited by 122 · cited 4×
“The loading frequencies and amplitudes utilized in this study were commensurate with those used in previous in vivo [7, 41] and in vitro [5, 40] studies and reflect accepted physiologic levels for normal tendon activity [42].”
BackgroundMethodResultInfluentialMajima, T., Yasuda, K., Yamamoto, N., Kaneda, K., & Hayashi, K. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200614 · Cited by 59
Interstitial fluid flow in tendons or ligaments: A porous medium finite element simulation
Butler, S. L., Kohles, S. S., Thielke, R. J., Chen, C., & Vanderby, R. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510987 · Cited by 52
Structure and Function of Normal and Healing Tendons and Ligaments
Viidik, A. (1990) · Springer eBooks · doi:10.1007/978-1-4612-3448-7_1 · Cited by 46 · cited 1×
“The loading frequencies and amplitudes utilized in this study were commensurate with those used in previous in vivo [7, 41] and in vitro [5, 40] studies and reflect accepted physiologic levels for normal tendon activity [42].”
ResultImmobilization increases the vulnerability of rabbit medial collateral ligament autografts to creep
Boorman, R. S., Shrive, N. G., & Frank, C. B. (1998) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100160609 · Cited by 40
Ligament Tension Affects Nuclear Shape in Situ: Anin VitroStudy
Matyas, J. R., Edwards, P., Miniaci, A. A., Shrive, N. G., Wilson, J., Bray, R., & Frank, C. B. (1994) · Connective Tissue Research · doi:10.3109/03008209409005634 · Cited by 26 · cited 1×
“Previous in vitro studies in ligaments and tendons have shown that tensile loading produces substrate (extracellular matrix) strain that, in turn, alters cell shape [33, 34].”
Background
Cited by
Wang, J. H.-C. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.011 · Cited by 1,002
Kongsgaard, M., Kovanen, V., Aagaard, P., Doessing, S., Hansen, P., Laursen, A. H., Kaldau, N. C., Kjaer, M., & Magnusson, S. P. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2009.00949.x · Cited by 471
Bohm, S., Mersmann, F., & Arampatzis, A. (2015) · Sports Medicine - Open · doi:10.1186/s40798-015-0009-9 · Cited by 458
Mechanotherapy: how physical therapists’ prescription of exercise promotes tissue repair
Khan, K. M., & Scott, A. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.054239 · Cited by 434
Snedeker, J. G., & Foolen, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.08.032 · Cited by 377
Metadata
- Authors
- Lavagnino, M., Arnoczky, S. P., Tian, T., & Vaupel, Z.
- Venue
- Connective Tissue Research
- Publisher
- Informa UK Limited
- Published
- 2003-01
- Volume
- 44
- Issue
- 3-4
- Pages
- 181-187
- ISSN
- 0300-8207 (ISSN-L)
- 1607-8438
- OpenAlex
- W2033673494
- Cited by
- 175
- References
- 32
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.