Solid-phase extraction using multiwalled carbon nanotubes and quinalizarin for preconcentration and determination of trace amounts of some heavy metals in food, water and environmental samples
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A solid phase extraction procedure has been developed using multiwalled carbon nanotubes (MWCNTs) as a solid sorbent and quinalizarin [1,2,5,8-tetrahydroxyanthracene-9,10-dione] as a chelating agent for separation and preconcentration of trace amounts of some heavy metal ions, Cd(II), Cu(II), Ni(II), Pb(II) and Zn(II) before their determination by flame atomic absorption spectroscopy (FAAS). The influences of the analytical parameters, including pH, amounts of quinalizarin and adsorbent, sample volume, elution conditions such as volume and concentration of eluent, flow rates of solution and matrix ions, were investigated for the optimum recoveries of the analyte ions. No interference effects were observed from the foreign metal ions. The preconcentration factor was 100. The detection limit (LOD) for the investigated metals at the optimal conditions were observed in the range of 0.30–0.65 μg L−1. The relative standard deviation (RSDs), and the recoveries of standard addition for this method were lower than 5.0% and 96–102%, respectively. The new procedure was successfully applied to the determination of analytes in food, water and environmental samples with satisfactory results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ALqadami, A., Abdalla, M., ALOthman, Z., & Omer, K. (2013) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph10010361 · Cited by 100
Cited by
Ozdes, D., & Duran, C. (2021) · Environmental Monitoring and Assessment · doi:10.1007/s10661-021-09389-0 · Cited by 40
“The complicated matrix that consists of a great number of concomitant cations and anions together with heavy metal ions to be analyzed and the lower concentrations of heavy metals than the quantification limit of the aforementioned instrumental techniques restrict the accurate and sensitive analysis (Gouda, 2014).”
BackgroundAlothman, Z. A., Al-Shaalan, N. H., Habila, M. A., Unsal, Y. E., Tuzen, M., & Soylak, M. (2015) · Environmental Monitoring and Assessment · doi:10.1007/s10661-014-4160-4 · Cited by 22
“In addition, several researchers have used these methods for chemical analyte/matrix separations (Divrikli et al. 2007; Bahadir et al. 2014; Vellaichamy and Palanivelu 2011; Gouda 2014); however, the concentration of trace lead was lower than the detection limits, and matrix effects were observed.”
MethodDuran, C., & Ozdes, D. (2023) · International Journal of Environmental Analytical Chemistry · doi:10.1080/03067319.2021.1931856 · Cited by 17
Metadata
- Authors
- Gouda, A. A.
- Venue
- International Journal of Environmental Analytical Chemistry
- Publisher
- Informa UK Limited
- Published
- 2014-09-02
- Volume
- 94
- Issue
- 12
- Pages
- 1210-1222
- ISSN
- 0306-7319 (ISSN-L)
- 1029-0397
- OpenAlex
- W2091724474
- Cited by
- 42
- References
- 1
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.