CoChat

Ionic liquids versus ionic liquid-based surfactants in dispersive liquid–liquid microextraction for determining copper in water by flame atomic absorption spectrometry

Ayala-Cabrera, Juan F., Trujillo-Rodríguez, María J., Pino, Verónica, Hernández-Torres, Óscar M., Afonso, Ana M., Sirieix-Plénet, Juliette · 2016 · International Journal of Environmental Analytical Chemistry
Cited by 39

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Juan F. Ayala-Cabreraa, María J. Trujillo-Rodrígueza, Verónica Pinoa*, Óscar M. Hernández-Torresa, Ana M. Afonsoa & Juliette Sirieix-Plénetba Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna (Tenerife), Spainb CNRS, Laboratoire PHENIX, Sorbonne Universités, UPMC Univ Paris 06, Paris, FranceCONTACT Verónica Pino veropino@ull.edu.esABSTRACTThis work compares the performance of dispersive liquid–liquid method (DLLME) as a prior step for determining copper by flame atomic absorption spectrometry (FAAS), when using the ionic liquid (IL) 1-butyl-3-methylimidazolium hexafluorophosphate (C4MIm-PF6) or the IL-based surfactant 1-hexadecyl-3-butylimidazolium bromide (C16C4Im-Br) as extractant solvents. For the water-insoluble C4MIm-PF6, the most conventional DLLME mode using acetonitrile as dispersive solvent was employed. For the water-soluble C16C4Im-Br, the in situ DLLME mode with lithium bis[(trifluoromethane)sulfonyl]imide (Li-NTf2) as metathesis reagent was employed. In both approaches, some effective parameters such as volumes of extractant and dispersive solvents, concentration of complexing agent, pH of sample solution, salting-out effect and final diluting solvent to ensure compatibility with FAAS, were properly optimised. The optimum conditions for the IL-DLLME method using C4MIm-PF6 were: 100 μL of neat C4MIm-PF6, 1 mL of acetonitrile, 10 mL of water, no control of pH for environmental waters, NaCl content of 23 g L−1, diethyl dithiocarbamate (DDTC) as complexing agent at 10 mg L−1 and final dilution of the micro-droplet with acetonitrile up to 70 µL. The optimum conditions for the in situ IL-DLLME method using C16C4Im-Br were: 0.8 mL of acetonitrile, 10 mL of water containing C16C4Im-Br at 25.2 mmol L−1, final dilution step of the micro-droplet with 200 µL of acetonitrile and remaining conditions as those of C4MIm-PF6. The analytical performance of both methods was similar, being slightly better for the IL-DLLME method using C4MIm-PF6, with limits of detection (LOD) of 3.3 µg L−1 (versus 5.1 µg L−1 when using C16C4Im-Br), precision values as intraday relative standard deviation (RSD in %) lower than 8.8% (being of 10% for the C16C4Im-Br method) and an enrichment factor of 54 (being 27 when using C16C4Im-Br). The DLLME-FAAS method with C4MIm-PF6 was used in the analysis of environmental waters with successful performance, with relative recoveries of 110% and 105%, and interday precision with RSD values of 21% and 7.4% for spiked levels of 60 and 160 µg L−1, respectively. The results obtained when analysing an urban wastewater sample coming from an inter-laboratory exercise was comparable to those obtained for other 93 laboratories. The method was also valid for the determination of Cu2+ in presence of foreign ions commonly found in natural waters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/03067319.2015.1128538

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Research works printed but not linked: 35

  1. 10.1016/j.watres.2014.08.013 · DOI · Paper page
  2. 10.1007/s00604-010-0402-5 · DOI
  3. 10.1016/0048-9697(75)90029-7 · DOI
  4. National Research Council,Dietary Reference Intakes for Vitamin A, Vitamin K, Arsenic, Boron, Chromium, Copper, Iodine, Iron, Manganese, Molybdenum, Nickel, Silicon, Vanadium and Zinc(National Academy Press, Washington, DC, 2001), p. 224.
  5. United States Environmental Protection Agency (US-EPA), 2014, National Primary Drinking Water Regulations, List of Contaminants and Their Maximum Contaminant Levels
  6. World Health Organization (WHO), 2004, Copper in Drinking-Water, Background Document for Development of WHO Guidelines for Drinking-Water Quality
  7. 10.1039/c3ay41112e · DOI
  8. 10.1002/jms.1216 · DOI · Paper page
  9. 10.1016/j.jenvman.2014.11.030 · DOI · Paper page
  10. 10.1016/j.aca.2008.02.034 · DOI
  11. 10.1016/j.saa.2011.05.095 · DOI
  12. 10.1016/j.talanta.2014.05.048 · DOI
  13. 10.1016/j.saa.2015.03.129 · DOI
  14. 10.1016/j.trac.2012.10.011 · DOI
  15. 10.1016/j.sab.2012.05.003 · DOI
  16. 10.1016/j.talanta.2010.10.052 · DOI
  17. 10.1126/science.1090313 · DOI · Paper page
  18. 10.1021/ac4035554 · DOI · Paper page
  19. 10.1080/01496395.2011.620589 · DOI · Paper page
  20. 10.1002/9781118854501.ch23 · DOI
  21. 10.1016/j.talanta.2012.07.073 · DOI
  22. 10.1016/j.talanta.2011.04.054 · DOI
  23. 10.1016/j.chroma.2011.12.097 · DOI
  24. 10.1016/j.desal.2010.08.032 · DOI
  25. 10.1016/j.molliq.2014.01.026 · DOI
  26. 10.1016/j.foodchem.2014.07.015 · DOI
  27. 10.1080/00032719.2014.999276 · DOI · Paper page
  28. 10.1007/s00604-014-1434-z · DOI
  29. 10.1007/s00604-011-0757-2 · DOI
  30. 10.1039/b615406a · DOI · Paper page
  31. 10.1016/j.fct.2010.03.005 · DOI
  32. 10.1016/j.aca.2008.12.017 · DOI · Paper page
  33. 10.1016/j.chroma.2013.05.009 · DOI
  34. 10.1016/j.talanta.2009.12.038 · DOI
  35. 10.1016/j.aca.2014.04.057 · DOI · Paper page

Cited by

See all 39

Metadata

Authors
Ayala-Cabrera, J. F., Trujillo-Rodríguez, M. J., Pino, V., Hernández-Torres, Ó. M., Afonso, A. M., & Sirieix-Plénet, J.
Venue
International Journal of Environmental Analytical Chemistry
Published
2015-12-29
Volume
96
Issue
2
Pages
101-118
ISSN
  • 0306-7319 (ISSN-L)
  • 1029-0397
OpenAlex
W2203434971
Cited by
39
References
8
FWCI
3.50
Type
journal article
Language
en
Open access
closed
Funders
  • Fundación CajaCanarias (Project ref. SPDs–AGUA05)
  • Spanish Ministry of Economy and Competitiveness (MINECO) (Project Ref. MAT2014–57465–R, Project ref. MAT2013-43101-R, Ramón y Cajal contract)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ionic liquids versus ionic liquid-based surfactants in dispersive liquid–liquid microextraction for determining copper in water by flame atomic absorption spectrometry. https://app.cochat.ai/papers/10.1080/03067319.2015.1128538
The paper
Ayala-Cabrera, J. F., Trujillo-Rodríguez, M. J., Pino, V., Hernández-Torres, Ó. M., Afonso, A. M., & Sirieix-Plénet, J. (2016). Ionic liquids versus ionic liquid-based surfactants in dispersive liquid–liquid microextraction for determining copper in water by flame atomic absorption spectrometry. International Journal of Environmental Analytical Chemistry. https://doi.org/10.1080/03067319.2015.1128538

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.