The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities
Open accessAbstract
This review article is a summary of the publications dealing with the pulmonary applications of electrical impedance tomography (EIT). Original papers on EIT lung imaging published over 15 years are analysed and several aspects of the performed EIT measurements summarized. Information on the type of the EIT device and electrodes used, the studied transverse thoracic planes, the data acquisition rate, the number of studied animals, normal subjects or patients, the kind of lung pathology, the performed ventilatory manoeuvres and other interventions, as well as the applied reference techniques, is given. The type of the generated pulmonary EIT images and the quantitative analysis of the EIT data are described. Finally, the major results achieved are presented, followed by an analysis of the perspectives of EIT in clinical applications. A comparative analysis of the EIT hardware and the quality of the evaluation tools was not performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Barber, D. C., & Brown, B. H. (1984) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/17/9/002 · Cited by 726
Imaging with electricity: Report of the European Concerted Action on Impedance Tomography
Boone, K., Barber, D., & Brown, B. (1997) · Journal of Medical Engineering & Technology · doi:10.3109/03091909709070013 · Cited by 192
Changes in the thoracic impedance distribution under different ventilatory conditions
Hahn, G., Šipinková, I., Baisch, F. J., et al. (1995) · Physiological Measurement · doi:10.1088/0967-3334/16/3a/016 · Cited by 154
Multi-frequency imaging and modelling of respiratory related electrical impedance changes
Brown, B. H., Barber, D. C., Wang, W., Lu, L., Leathard, A. D., Smallwood, R. H., Hampshire, A., Mackay, R., & Hatzigalanis, K. (1994) · Physiological Measurement · doi:10.1088/0967-3334/15/2a/001 · Cited by 104
An experimental study in electrical impedance tomography using backprojection reconstruction
Guardo, R., Boulay, C., Murray, B., et al. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83560 · Cited by 61
Kunst, P. W. A., VRIES, P. M. J. M. D., Postmus, P. E., & Bakker, J. (1999) · CHEST Journal · doi:10.1378/chest.115.4.1102 · Cited by 60
Marven, S. S., Hampshire, A., Smallwood, R. H., Brown, B. H., & Primhak, R. A. (1996) · Physiological Measurement · doi:10.1088/0967-3334/17/4a/025 · Cited by 18
Cited by
Electrical impedance tomography (EIT): a review
Brown, B. (2003) · Journal of Medical Engineering & Technology · doi:10.1080/0309190021000059687 · Cited by 556
Metadata
- Authors
- Frerichs, I.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2000-05-01
- Volume
- 21
- Issue
- 2
- Pages
- R1-R21
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1992681652
- Cited by
- 348
- References
- 9
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities. https://app.cochat.ai/papers/10.1088/0967-3334/21/2/201
- The paper
- Frerichs, I. (2000). Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities. Physiological Measurement. https://doi.org/10.1088/0967-3334/21/2/201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.