The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Imaging with electricity: Report of the European Concerted Action on Impedance Tomography
Abstract
(1997). Imaging with electricity: Report of the European Concerted Action on Impedance Tomography. Journal of Medical Engineering & Technology: Vol. 21, No. 6, pp. 201-232.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Cited by
Tissue Ablation with Irreversible Electroporation
Davalos, R. V., Mir, L. M., & Rubinsky, B. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8981-8 · Cited by 1,293
Electrical impedance tomography (EIT): a review
Brown, B. (2003) · Journal of Medical Engineering & Technology · doi:10.1080/0309190021000059687 · Cited by 556
Self-citationFrerichs, I. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/201 · Cited by 348
The dielectric properties of biological cells at radiofrequencies: applications in biotechnology
Markx, G. H., & Davey, C. L. (1999) · Enzyme and Microbial Technology · doi:10.1016/s0141-0229(99)00008-3 · Cited by 333
A 32-channel time-resolved instrument for medical optical tomography
Schmidt, F. E. W., Fry, M. E., Hillman, E. M. C., Hebden, J. C., & Delpy, D. T. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150191 · Cited by 260
Metadata
- Authors
- Boone, K., Barber, D., & Brown, B.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 1997-01
- Volume
- 21
- Issue
- 6
- Pages
- 201-232
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2109406621
- Cited by
- 192
- References
- 3
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging with electricity: Report of the European Concerted Action on Impedance Tomography. https://app.cochat.ai/papers/10.3109/03091909709070013
- The paper
- Boone, K., Barber, D., & Brown, B. (1997). Imaging with electricity: Report of the European Concerted Action on Impedance Tomography. Journal of Medical Engineering & Technology. https://doi.org/10.3109/03091909709070013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.