CoChat

Validation of the Fitbit One, Garmin Vivofit and Jawbone UP activity tracker in estimation of energy expenditure during treadmill walking and running

Price, Kym, Bird, Stephen R., Lythgo, Noel, Raj, Isaac S., Wong, Jason Y. L., Lynch, Chris · 2017 · Journal of Medical Engineering & Technology
Cited by 87

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Objectives: To determine the validity of energy expenditure estimation made by the Fitbit One, Garmin Vivofit and Jawbone UP activity trackers during treadmill walking and running. Determining validity of such trackers will inform the interpretation of the data they generate.Design: Cross-sectional study.Method: Fourteen adults walked at 0.70, 1.25, 1.80 ms−1 and ran at 2.22, 2.78, 3.33 ms−1 on a treadmill wearing a Fitbit One, Garmin Vivofit and Jawbone UP. Estimation of energy expenditure from each tracker was compared to measurement from indirect calorimetry (criterion). Paired t-tests, correlation coefficients and Bland–Altman plots assessed agreement and proportional bias. Mean percentage difference assessed magnitude of difference between estimated and criterion energy expenditure for each speed.Results: Energy expenditure estimates from the Fitbit One and Garmin Vivofit correlated significantly (p< 0.01; r= 0.702; 0.854) with criterion across all gait speeds (0.70–3.33 ms−1). Fitbit One, Garmin Vivofit and Jawbone UP correlated significantly (p < 0.05; r = 0.729; 0.711; 0.591) with criterion across all walking speeds (0.70–1.80 ms−1). However, only the Garmin Vivofit correlated significantly (p< 0.05; r = 0.346) with energy expenditure estimations from criterion across running speeds (2.22–3.33 ms−1). Bland–Altman plots showed proportional bias for the Fitbit One and Garmin Vivofit. Energy expenditure estimations of single speeds were overestimated by the Fitbit One and underestimated by the Garmin Vivofit.Conclusions: Energy expenditure reported by the devices distinguished between walking and running, with a general increase as exercise intensity increased. However, the reported energy expenditure from these devices should be interpreted with caution, given their potential bias and error.Practical implicationsAlthough devices report the same outcome of EE estimation, they are not equivalent to each other and differ from criterion measurements during walking and running.These devices are not suitable as research measurement tools for recording precise and accurate EE estimates but may be suitable for use in interventions of behaviour change as they provide feedback to user on trends in energy expenditure.If intending to use these devices in studies where precise measurements of energy expenditure are required, researchers need to undertake specific validation and reliability studies prior to interventions and the collection of cross-sectional data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/03091902.2016.1253795

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 87

Metadata

Authors
Price, K., Bird, S. R., Lythgo, N., Raj, I. S., Wong, J. Y. L., & Lynch, C.
Venue
Journal of Medical Engineering & Technology
Published
2016-12-05
Volume
41
Issue
3
Pages
208-215
ISSN
  • 0309-1902 (ISSN-L)
  • 1464-522X
OpenAlex
W2560086155
Cited by
87
References
11
FWCI
8.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.