Accuracy and Acceptability of Wrist-Wearable Activity-Tracking Devices: Systematic Review of the Literature

Open access
Germini, Federico, Noronha, Noella, Borg Debono, Victoria, Abraham Philip, Binu, Pete, Drashti, Navarro, Tamara, Keepanasseril, Arun, Parpia, Sameer, de Wit, Kerstin, Iorio, Alfonso · 2022 · Journal of Medical Internet Research
Cited by 220

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

Background: Numerous wrist-wearable devices to measure physical activity are currently available, but there is a need to unify the evidence on how they compare in terms of acceptability and accuracy. Objective: The aim of this study is to perform a systematic review of the literature to assess the accuracy and acceptability (willingness to use the device for the task it is designed to support) of wrist-wearable activity trackers. Methods: We searched MEDLINE, Embase, the Cochrane Central Register of Controlled Trials, and SPORTDiscus for studies measuring physical activity in the general population using wrist-wearable activity trackers. We screened articles for inclusion and, for the included studies, reported data on the studies’ setting and population, outcome measured, and risk of bias. Results: A total of 65 articles were included in our review. Accuracy was assessed for 14 different outcomes, which can be classified in the following categories: count of specific activities (including step counts), time spent being active, intensity of physical activity (including energy expenditure), heart rate, distance, and speed. Substantial clinical heterogeneity did not allow us to perform a meta-analysis of the results. The outcomes assessed most frequently were step counts, heart rate, and energy expenditure. For step counts, the Fitbit Charge (or the Fitbit Charge HR) had a mean absolute percentage error (MAPE) <25% across 20 studies. For heart rate, the Apple Watch had a MAPE <10% in 2 studies. For energy expenditure, the MAPE was >30% for all the brands, showing poor accuracy across devices. Acceptability was most frequently measured through data availability and wearing time. Data availability was ≥75% for the Fitbit Charge HR, Fitbit Flex 2, and Garmin Vivofit. The wearing time was 89% for both the GENEActiv and Nike FuelBand. Conclusions: The Fitbit Charge and Fitbit Charge HR were consistently shown to have a good accuracy for step counts and the Apple Watch for measuring heart rate. None of the tested devices proved to be accurate in measuring energy expenditure. Efforts should be made to reduce the heterogeneity among studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/30791

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 220

Metadata

Authors
Germini, F., Noronha, N., Borg Debono, V., Abraham Philip, B., Pete, D., Navarro, T., Keepanasseril, A., Parpia, S., de Wit, K., & Iorio, A.
Venue
Journal of Medical Internet Research
Published
2022-01-21
Volume
24
Issue
1
Pages
e30791
ISSN
1438-8871 (ISSN-L)
OpenAlex
W4205192005
Cited by
220
References
18
FWCI
5.01
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and Acceptability of Wrist-Wearable Activity-Tracking Devices: Systematic Review of the Literature. https://app.cochat.ai/papers/10.2196/30791
The paper
Germini, F., Noronha, N., Borg Debono, V., Abraham Philip, B., Pete, D., Navarro, T., Keepanasseril, A., Parpia, S., de Wit, K., & Iorio, A. (2022). Accuracy and Acceptability of Wrist-Wearable Activity-Tracking Devices: Systematic Review of the Literature. Journal of Medical Internet Research. https://doi.org/10.2196/30791

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.