Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 314

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Development and measurement properties of the Orthotics and Prosthetics Users’ Survey (OPUS): A comprehensive set of clinical outcome instruments

Heinemann, A. W., Bode, R. K., O'Reilly, C. · 2003 · Prosthetics & Orthotics International

Abstract

The need to measure and evaluate orthotics and prosthetics (O&P) practice has received growing recognition in the past several years. Reliable and valid self-report instruments are needed that can help facilities evaluate patient outcomes. The objective of this project was to develop a set of self-report instruments that assess functional status, quality of life, and satisfaction with devices and services that can be used in an orthotics and prosthetics clinic. Selecting items from a variety of existing instruments, the authors developed and revised four instruments that differentiate patients with varying levels of lower limb function, quality of life, and satisfaction with devices and services. Evidence of construct validity is provided by hierarchies of item difficulty that are consistent with clinical experience. For example, with the lower limb function instrument, running one block was much more difficult than walking indoors. The instruments demonstrate adequate internal consistency (0.88 for lower limb function, 0.88 for quality of life, 0.74 for service satisfaction, 0.78 for device satisfaction). The next steps in their research programme are to evaluate sensitivity and construct validity. The Orthotics and Prosthetics Users' Survey (OPUS) is a promising self-report instrument which may, with further development, allow orthotic and prosthetic practitioners to evaluate the quality and effectiveness of their services as required by accreditation standards such as those of the American Board for Certification in Orthotics and Prosthetics that mandate quality assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/03093640308726682

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Heinemann, A. W., Bode, R. K., & O'Reilly, C.
Venue
Prosthetics & Orthotics International
Published
2003-12
Volume
27
Issue
3
Pages
191-206
ISSN
0309-3646 (ISSN-L)
OpenAlex
W2159059915
Cited by
314
References
11
FWCI
2.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and measurement properties of the Orthotics and Prosthetics Users’ Survey (OPUS): A comprehensive set of clinical outcome instruments. https://app.cochat.ai/papers/10.1080/03093640308726682
The paper
Heinemann, A. W., Bode, R. K., & O'Reilly, C. (2003). Development and measurement properties of the Orthotics and Prosthetics Users’ Survey (OPUS): A comprehensive set of clinical outcome instruments. Prosthetics & Orthotics International. https://doi.org/10.1080/03093640308726682

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.